To do...
Set the history command
buffer size
Set the timeout time of the
VTY user interface
Note that if you configure not to authenticate the users, the command level available to users logging in
to the switching engine depends on the user privilege level level command

Configuration Example

Network requirements
As shown in
Figure
user level is set to the manage level (level 3). Perform the following configurations for users logging in
through VTY 0 using Telnet.
Do not authenticate the users.
Commands of level 2 are available to the users.
Telnet protocol is supported.
The screen can contain up to 30 lines.
The history command buffer can contain up to 20 commands.
The timeout time of VTY 0 is 6 minutes.
Figure 3-1 Network diagram for Telnet configuration (with the authentication mode being none)
Configuration procedure
# Enter system view.
<device> system-view
# Enter VTY 0 user interface view.
[device] user-interface vty 0
# Configure not to authenticate Telnet users logging in through VTY 0.
[device-ui-vty0] authentication-mode none
Use the command...
history-command
max-size value
idle-timeout minutes
[ seconds ]
3-1, assume current user logs in using the oap connect slot 0 command, and the
Optional
The default history command buffer
size is 10. That is, a history command
buffer can store up to 10 commands by
default.
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10 minutes,
the connection to a user interface is
terminated if no operation is performed
in the user interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.