3Com WX3000 Series Operation Manual page 632

Unified switches switching engine
Table of Contents

Advertisement

[device-hwping-administrator-ftp] count 10
# Set the probe timeout time to 30 seconds.
[device-hwping-administrator-ftp] timeout 30
# Configure the source IP address
[device-hwping-administrator-ftp] source-ip 10.1.1.1
# Start the test.
[device-hwping-administrator-ftp] test-enable
# Display test results
[device-hwping-administrator-ftp] display hwping results administrator ftp
HWPing entry(admin administrator, tag ftp) test result:
Destination ip address:10.2.2.2
Send operation times: 10
Min/Max/Average Round Trip Time: 3245/15891/12157
Square-Sum of Round Trip Time: 1644458573
Last complete test time: 2000-4-3 4:0:34.6
Extend result:
SD Maximal delay: 0
Packet lost in test: 0%
Disconnect operation number: 0
System busy operation number: 0
Operation sequence errors: 0
Other operation errors: 0
[device-hwping-administrator-ftp] display hwping history administrator ftp
HWPing entry(admin administrator, tag ftp) history record:
Index
Response
1
15822
2
15772
3
9945
4
15891
5
15772
6
15653
7
9792
8
9794
9
9891
10
3245
For detailed output description, see the corresponding command manual.
If you are downloading a file from the server, you do not need to specify an FTP operation type. For
details, see
Configuring FTP test on HWPing
Receive response times: 10
DS Maximal delay: 0
Operation timeout number: 0
Connection fail number: 0
Drop operation number: 0
Status
LastRC
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
client.
1-21
Time
2000-04-03 04:00:34.6
2000-04-03 04:00:18.8
2000-04-03 04:00:02.9
2000-04-03 03:59:52.9
2000-04-03 03:59:37.0
2000-04-03 03:59:21.2
2000-04-03 03:59:05.5
2000-04-03 03:58:55.6
2000-04-03 03:58:45.8
2000-04-03 03:58:35.9