Table 6-1. Menu Table-Fibre Channel Configuration - StorageTek 9840 Product Manual

Hide thumbs Also See for 9840:
Table of Contents

Advertisement

Table 6-1
Channel drive when the drive is offline.
Table 6-1. Menu Table—Fibre Channel Configuration
Options
Notes
Online/Offline Main Menu
Defaults to Online at power-on.
Online/
Offline
Offline must be selected to
change configuration settings.
OffLn Pend may display while
waiting for a system response or
diagnostics completion.
Port A Enable/Disable Menu
Defaults to enabled (ENA).
Port A enabled. (Normal for
Port A ENA
single port configuration.)
Port A disabled (DIS).
Port A DIS
DIS Pend or ENA Pend may
display while waiting for a system
response.
Note: Manufacturing ships drive with the Port A ENA option selected.
Port B Enable/Disable Menu
Defaults to ENA.
Port B enabled.
Port B ENA
Port B disabled. (Normal for
Port B DIS
single port configuration.)
DIS Pend or ENA Pend may
display while waiting for a system
response.
Note: Manufacturing ships drive with the Port B ENA option selected.
Change Configuration Main Menu
This is the entry point to the
Chng CFG ?
Configuration submenus.
95741
provides detailed instructions to change configuration of a Fibre
Sixth Edition
Fibre Channel Change Configuration
Procedure
1. If required, press
Menu
until Online or Offline is
displayed.
2. If Online, press
Select
option to Offline.
3. Press
to advance to the Port
Menu
A Enable/Disable menu.
1. Press
to bypass, or
Menu
2. Press
to toggle option;
Select
then, press
to set, and
Menu
advance to the Port B Enable/
Disable menu.
1. Press
to bypass, or
Menu
2. Press
to toggle option;
Select
then, press
to set, and
Menu
advance to the Change
Configuration (Chng CFG) Main
Menu.
1. Press
to enter
Select
Configuration submenus, or
2. Press
to bypass.
Menu
repeatedly
to toggle
6-13