Positioning Completion Signal

Inverter gives out the positioning signal when positioning performance is done.
To use this function, assign
Refer to chapter 4 for the details of the performance.
Option
Terminal
Code
Symbol
POK
Positioning
23
completion signal
11, 12, AL0 – AL2
Valid for inputs:
P0103~P015
Required settings
Notes:
• The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter's output transistor.
"23
(POK)" to one of the intelligent output terminals.
Function Name
State
ON
OFF
Description
Positioning performance is completed
Positioning performance is not completed
Example for terminal [11] (default output
configuration shown – see
Inverter output
terminal circuit
CM2
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
Inverter logic
circuit board
AL0
AL1
Power
supply
See I/O specs on
page 4-6
4−69
page
3-90):
POK
11
RY
page 4-52 and
3-90):
POK
AL2
Load