Hitachi WJ200 Series Instruction Manual page 141

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

3−60
Func.
Code
Initial display selection
b038
Frequency scaling
B086
conversion factor
Display ex.operator
b150
connected
1st parameter of Dual
b160
Monitor
2nd parameter of Dual
b161
Monitor
Frequency set in monitoring
b163
Automatic return to the
b164
initial display
Ex. operator com. loss action
b165
(*) note: If the power is off with displaying "000" after the set, b038 comes when power is on
again.
"b" Function
Name
000...Func. code that SET key
001~030...d001~d030 displayed
201...F001 displayed
202...B display of LCD operator
Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.01 to 99.99
When an external operator is
connected via RS-422 port, the
built-in display is locked and
shows only one "d" parameter
configured in:
d001 ~ d030
Set any two "d" parameters in
b160 and b161, then they can be
monitored in d050. The two
parameters are switched by
up/down keys.
Set range: d001 ~ d030
Two option codes:
00...Freq. set disabled
01...Freq. set enabled
10 min. after the last key
operation, display returns to the
initial parameter set by b038.
Two option codes:
00...Disable
01...Enable
Five option codes:
00...Trip
01...Trip after deceleration to a
02...Ignore
03...Coasting (FRS)
04...Decelerates to a stop
Description
pressed last displayed.(*)
stop
Run
Defaults
Mode
Lnitial data
Units
Edit
001
1.00
001
001
002
00
00
02