Hitachi WJ200 Series Instruction Manual page 161

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

3−80
Function
Rating
Max. freq. (A004)
Start freq. (b082)
Carrier freq. (b083)
V/f characteristic curve
(A044)
b171 = 02
+ init.
High frequency mode
HD
1000Hz
0.10 to 100.0 (Hz)
2.0 to 10.0 (kHz)
00: Const. torque
01: Reduced torque
02: Free V/f
Normal mode(~400Hz)
HD mode
HD mode
b049: 00
d060: 1-C
b171 = 01
+ init.
High freq. mode
d060: H-1
High freq(~1000Hz)
HD
400Hz
0.10 to 9.99 (Hz)
2.0 to 15.0 (kHz)
00: Const. torque
01: Reduced torque
02: Free V/f
03: SLV
ND mode
b049 = 01
ND mode
b049: 01
b049 = 00
d060: 1-v
Standard mode
ND
400Hz
0.10 to 9.99 (Hz)
2.0 to 10.0 (kHz)
00: Const. torque
01: Reduced torque
02: Free V/f
b171 = 02
+ init.

Advertisement

Table of Contents
loading

Table of Contents