Hitachi WJ200 Series Instruction Manual page 391

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

C−10
Func.
Code
Curvature of EL-S-curve at
a151
the end of acceleration
Curvature of EL-S-curve at
a152
the start of deceleration
Curvature of EL-S-curve at
a153
the end of deceleration
Deceleration hold frequency
a154
Deceleration hold time
a155
PID sleep function action
a156
threshold
PID sleep function action
a157
delay time
[VR] input active range start
A161
frequency
[VR] input active range end
A162
frequency
[VR] input active range
A163
start %
[VR] input active range
A164
end %
[VR] input start frequency
A165
select
"A" Function
Name
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
Sets the frequency to hold
deceleration, range is 0.0 to
400.0Hz
Sets the duration of
deceleration hold, range is 0.0
to 60.0 seconds
Sets the threshold for the
action, set range 0.0~400.0 Hz
Sets the delay time for the
action, set range 0.0~25.5 sec
The output frequency
corresponding to the analog
input range starting point,
range is 0.0 to 400.0 Hz
The output frequency
corresponding to the current
input range ending point,
range is 0.0 to 400.0 Hz
The starting point (offset) for
the current input range,
range is 0. to 100.%
The ending point (offset) for the
current input range,
range is 0. to 100.%
Two options; select codes:
00...Use offset (A161 value)
01...Use 0Hz
Description
Run
Defaults
Mode
Lnitial data
Units
Edit
10.
%
10.
%
10.
%
0.0
Hz
0.0
sec.
0.00
Hz
0.0
sec
0.00
Hz
0.00
Hz
0.
%
100.
%
01