Hitachi WJ200 Series Instruction Manual page 173

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

3−92
Option
Terminal
Code
Symbol
22
DSE
23
POK
24
FA4
25
FA5
26
OL2
27
ODc
28
OIDc
31
FBV
32
NDc
33
LOG1
34
LOG2
35
LOG3
39
WAC
40
WAF
Output Function Summary Table
Function Name
Speed Deviation
Excessive
Positioning Completion
Frequency Arrival Type
4–Over frequency
Frequency Arrival Type
5–Set frequency
Overload Advance
Notice Signal 2
Analog Voltage Input
Disconnect Detection
Analog Current input
Disconnect Detection
PID Second Stage
Output
Network Disconnect
Detection
Logic Output Function 1
Logic Output Function 2
Logic Output Function 3
Capacitor Life Warning
Signal
Cooling Fan Warning
Signal
Description
OFF
Output frequency is higher than the threshold
specified in C063
ON
Deviation of speed command and actual speed
exceeds the specified value P027.
OFF
Deviation of speed command and actual speed
does not exceed the specified value P027.
ON
Positioning is completed
OFF
Positioning is not completed
ON
When output to motor is at or above the set freq.,
even if in accel (C045) or decel (C046) ramps
OFF
When output to motor is OFF, or at a level below the
set frequency
ON
When output to motor is at the set frequency, during
accel (C045) and decel (C046).
OFF
When output to motor is OFF, or is not at a level of
the set frequency
ON
When output current is more than the set threshold
(C111) for the overload signal
OFF
When output current is less than the set threshold
for the deviation signal
When the [O] input value < B070 setting (signal loss
ON
detected)
OFF
When no signal loss is detected
When the [OI] input value < B071 setting (signal loss
ON
detected)
OFF
When no signal loss is detected
ON
Transitions to ON when the inverter is in RUN Mode
and the PID Process Variable (PV) is less than the
Feedback Low Limit (C053)
OFF
Transitions to OFF when the PID Process Variable
(PV) exceeds the PID High Limit (C052), and
transitions to OFF when the inverter goes from Run
Mode to Stop Mode
ON
When the communications watchdog timer (period
specified by C077) has time out
OFF
When the communications watchdog timer is
satisfied by regular communications activity
When the Boolean operation specified by C143 has
ON
a logical "1" result
When the Boolean operation specified by C143 has
OFF
a logical "0" result
When the Boolean operation specified by C146 has
ON
a logical "1" result
When the Boolean operation specified by C146 has
OFF
a logical "0" result
When the Boolean operation specified by C149 has
ON
a logical "1" result
When the Boolean operation specified by C149 has
OFF
a logical "0" result
ON
Lifetime of internal capacitor has expired.
OFF
Lifetime of internal capacitor has not expired.
ON
Lifetime of cooling fan has expired.

Advertisement

Table of Contents
loading

Table of Contents