Electronic Thermal Warning Output - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

3−50
• Free setting (b013=02)
Reduction rate
x1.0
x0.8
0
Output frequency [Hz]
Electronic Thermal Warning Output: You can configure this function so that the
inverter outputs a warning signal before the electronic thermal protection operates
against motor overheat. You can also set the threshold level to output a warning signal
with the electronic thermal warning level setting in function "C061".
To output the warning signal, assign parameter "13" (THM) to one of the intelligent
output terminals [11] to [12] (C021 to C022), or to the relay output terminal (C026).
Setting range
3
400
Output current [A]
b020
b018
b016
0
b015
b017
b019
Output frequency [Hz]
A004 Max. FQ