Chapter 4
4.2.58 Intelligent output terminal setting
You can assign the functions described below to the intelligent output
terminals [11] to [15] (C021 to C025) and the alarm relay terminal
(C026).
The intelligent output terminals [11] to [15] are used for open-collector output, and the alarm relay terminal is used
for relay output.
You can select the a-contact or b-contact output for individual output terminals by using functions "C031" to "C035"
and "C036".
When "01" (3 bits) or "02" (4 bits) is specified for the alarm code output "C062" (see Section 4.2.65), the alarm code
output is assigned to output terminals 11 to 13 or output terminals 11 to 14 (AC0 to AC3), respectively. Subsequently,
the settings of "C021" to "C024" are invalidated.
Data
Description
00
RUN: Running signal
01
FA1: Constant-speed reached
02
FA2: Set frequency overreached
03
OL: Overload notice advance signal (1)
04
OD: Output deviation for PID control
05
AL: Alarm signal
06
FA3: Set frequency reached
07
OTQ: Over-torque
08
IP: Instantaneous power failure
09
UV: Undervoltage
10
TRQ: Torque limited
11
RNT: Operation time over
12
ONT: Plug-in time over
13
THM: Thermal alarm signal
19
BRK: Brake release
20
BER: Brake error
21
ZS: 0 Hz detection signal
22
DSE: Speed deviation maximum
23
POK: Positioning completed
24
FA4: Set frequency overreached 2
25
FA5: Set frequency reached 2
26
OL2: Overload notice advance signal (2)
27
Odc: Analog O disconnection detection
28
OIDc: Analog OI disconnection detection
29
O2Dc: Analog O2 disconnection detection
31
FBV: PID feedback comparison
32
NDc: Communication line disconnection
33
LOG1: Logical operation result 1
34
LOG2: Logical operation result 2
35
LOG3: Logical operation result 3
36
LOG4: Logical operation result 4
37
LOG5: Logical operation result 5
38
LOG6: Logical operation result 6
39
WAC: Capacitor life warning
40
WAF: Cooling-fan speed drop
41
FR: Starting contact signal
42
OHF: Heat sink overheat warning
43
LOC: Low-current indication signal
44
M01: General output 1
45
M02: General output 2
46
M03: General output 6
47
M04: General output 4
48
M05: General output 5
49
M06: General output 6
50
IRDY: Inverter ready
51
FWR: Forward rotation
52
RVR: Reverse rotation
Reference item
Running signal (RUN)
Frequency-arrival signals
Overload restriction/overload notice advance signal
PID function
Protective functions
Frequency-arrival signals
Over-torque signal
Instantaneous power failure/undervoltage
Torque limitation function
Operation time over signal
Plug-in time over signal
Electronic thermal protection
Brake control function
0 Hz detection signal
V2 control mode selection function
Orientation function
Frequency-arrival signals
Overload restriction/overload notice advance signal
Window comparators function
PID function
RS485
Logical operation function
Capacitor life warning
Cooling-fan speed drop
Starting contact signal
Heat sink overheat warning
Low-current indication signal
Easy sequence function
Inverter ready signal
Forward rotation signal
Reverse rotation signal
4-60
Explanation of Functions
Related code
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Availability(Yes or No)
CT mode
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Page
VT mode
4-62
Y
Y
4-62
Y
4-40
Y
4-26
Y
Y
4-62
Y
4-65
Y
Y
4-35
Y
4-92
Y
4-64
Y
4-64
Y
4-37
Y
N
4-81
N
4-64
Y
4-96
N
4-104
N
Y
4-62
Y
4-40
Y
Y
4-71
Y
Y
4-26
Y
4-67
Y
Y
Y
Y
4-66
Y
Y
Y
4-67
Y
4-68
Y
4-68
Y
4-68
Y
4-69
Y
Y
Y
Y
Y
Y
Y
4-69
Y
4-69
Y
4-70
Y

Advertisement

Table of Contents
loading

Table of Contents