Hitachi WJ200 Series Instruction Manual page 366

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Register
Function name
No.
Start freq. of active
131Fh
frequency matching
Software lock mode
1320h
selection
1321h
(Reserved)
Motor cable length
1322h
parameter
1323h
Run/power-on warning time
1324h
Rotation direction
1325h
restriction
Reduced voltage start
1326h
selection
Function code display
1327h
restriction
1328h
Initial display selection
Automatic user parameter
1329h
registration
132Ah
Torque limit selection
Torque limit 1 (fwd-power in
132Bh
4-quadrant mode)
Torque limit 2 (rev/regen. in
132Ch
4-quadrant mode)
Torque limit 3 (rev/power in
132Dh
4-quadrant mode)
Torque limit 4 (fwd/regen. in
132Eh
4-quadrant mode)
Torque limit LADSTOP
132Fh
enable
Reverse Run protection
1330h
enable
1331h to
(Reserved)
1332h
1333h
Dual Rating Selection
Controlled deceleration on
1334h
power loss
DC bus voltage trigger level
1335h
of ctrl. decel.
Over-voltage threshold of
1336h
ctrl. decel.
1337h
Deceleration time of ctrl.
1338h
decel.
Initial freq. drop of ctrl.
1339h
decel.
133Ah to
(Reserved)
133Eh
Maximum-limit level of
133Fh
window comparators O
Minimum-limit level of
1340h
window comparators O
Hysteresis width of window
1341h
comparators O
Maximum-limit level of
1342h
window comparators OI
Minimum-limit level of
1343h
window comparators OI
Hysteresis width of window
1344h
comparators OI
Function code
R/W
0 (frequency at the last shutoff), 1 (maximum
b030
R/W
frequency), 2 (set frequency)
0 (disabling change of data other than "b031"
when SFT is on), 1 (disabling change of data
other than "b031" and frequency settings
b031
R/W
when SFT is on), 2 (disabling change of data
other than "b031"), 3 (disabling change of data
other than "b031" and frequency settings), 10
(enabling data changes during operation)
-
-
-
R/W 5 to 20
b033
b034 (high)
R/W
0 to 65535
b034 (low)
R/W
0( Enable for
b035
R/W
forward only)/ 2 (Enable for reverse only)
0 (minimum reduced voltage start time) to 255
b036
R/W
(maximum reduced voltage start time)
0 (full display), 1 (function-specific display), 2
b037
R/W
(user setting), 3 (data comparison display), 4
(basicdisplay), 5(monitor display)
b038
R/W 001-060
b039
R/W 0 (disabling), 1 (enabling)
00 (quadrant-specific setting), 01 (switching by
b040
R/W
terminal), 02 (analog input)
b041
R/W 0 to 200/255 (no)
b042
R/W 0 to 200/255 (no)
b043
R/W 0 to 200/255 (no)
b044
R/W 0 to 200/255 (no)
b045
R/W 0 (disabling), 1 (enabling)
b046
R/W 0 (disabling), 1 (enabling)
-
-
-
b049
R/W 0(CT mode)/1(VT mode)
0 (disabling), 1 (enabling), 2, (nonstop
operation at momentary power failure (no
b050
R/W
restoration))
3, (nonstop operation at momentary power
failure (restoration to be done))
b051
R/W 0 to 10000
b052
R/W 0 to 10000
b053 (high)
R/W
0.01 to 36000
b053 (low)
R/W
b054
R/W 0 to 1000
-
-
-
b060
R/W
0. to 100. (lower limit : b061 + b062 *2) (%)
b061
R/W
0. to 100. (lower limit : b060 - b062*2) (%)
b062
R/W
0. to 10. (lower limit : b061 - b062 / 2) (%)
b063
R/W
0. to 100. (lower limit : b064 + b066 *2) (%)
b064
R/W
0. to 100. (lower limit : b063 - b066 *2) (%)
b065
R/W
0. to 10. (lower limit : b063 - b064 / 2) (%)
Monitoring and setting items
both dir)/ 1 (Enable for
B−37
Data
resolution
-
-
-
-
1 [10h]
-
-
-
-
-
-
1 [%]
1 [%]
1 [%]
1 [%]
-
-
-
-
-
0.1 [V]
0.1 [V]
0.01
[sec.]
0.01 [Hz]
-
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]