Function name
No.
124Fh
Frequency upper limit
1250h
1251h
Frequency lower limit
1252h
1253h
Jump freq. (center) 1
1254h
Jump freq. width
1255h
(hysteresis) 1
1256h
Jump freq. (center) 2
1257h
Jump freq. width
1258h
(hysteresis) 2
1259h
Jump freq. (center) 3
125Ah
Jump freq. width
125Bh
(hysteresis) 3
125Ch
Acceleration hold frequency
125Dh
125Eh
Acceleration hold time
125Fh
PID Function Enable
1260h
PID proportional gain
1261h
PID integral time constant
1262h
PID derivative gain
1263h
PV scale conversion
1264h
PV source
1265h
Reverse PID
1266h
PID output limiter
1267h
PID feed forward selection
1268h
(Reserved)
1269h
AVR function select
126Ah
AVR voltage select
126Bh
AVR filter time constant
126Ch
AVR deceleration gain
Energy-saving operation
126Dh
mode
126Eh
Energy-saving mode tuning
Function code
R/W
A061 (high)
R/W 0 or "maximum frequency limit" to
"maximum frequency"
A061 (low)
R/W
A062 (high)
R/W 0 or "maximum frequency limit" to
"maximum frequency"
A062 (low)
R/W
A063 (high)
R/W
0 to 40000(100000)
A063 (low)
R/W
A064
R/W 0 to 1000(10000)
A065 (high)
R/W
0 to 40000(100000)
A065 (low)
R/W
A066
R/W 0 to 1000(10000)
A067 (high)
R/W
0 to 40000(100000)
A067 (low)
R/W
A068
R/W 0 to 1000(10000)
A069 (high)
R/W
0 to 40000
A069 (low)
R/W
A070
R/W 0 to 600
0 (disabling), 1 (enabling), 2 (enabling
A071
R/W
inverted-data output)
A072
R/W 0 to 2500
A073
R/W 0 to 36000
A074
R/W 0 to 10000
A075
R/W 1 to 9999
0 (input via OI), 1 (input via O), 2 (external
A076
R/W
communication), 3 (pulse train frequency
input), 10 (operation result output)
A077
R/W 00 (disabling), 01 (enabling)
A078
R/W 0 to 1000
A079
R/W 0 (disabled), 1(O input), 2 (OI input)
-
R/W -
0 (always on), 1 (always off), 2 (off during
A081
R/W
deceleration)
200 V class: 0 (200)/1 (215)/2 (220)/3
(230)/4 (240)
A082
R/W
400 V class: 5 (380)/6 (400)/7 (415)/8
(440)/9 (460)/ 10 (480)
R/W 0.000 to 10.00
A083
A084
R/W 50 to 200
0 (normal operation), 1 (energy-saving
A085
R/W
operation)
A086
R/W 0 to 1000
Monitoring and setting items
B−33
Data
resolution
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.1 [sec.]
-
0.10
0.1 [sec.]
0.01 [sec.]
0.01
-
-
0.1 [%]
-
-
-
-
0.001[sec]
1[%]
-
0.1 [%]