Func.
Name
Code
Cooling fan control
B092
Clear elapsed time of cooling
B093
fan
Initialization target data
b094
Dynamic braking control
b095
(BRD) selection
BRD activation level
b096
B100
Free V/F setting, freq.1
Free V/F setting, voltage.1
b101
b102
Free V/F setting, freq.2
Free V/F setting, voltage.2
b103
Free V/F setting, freq.3
b104
b105
Free V/F setting, voltage.3
Free V/F setting, freq.4
b106
b107
Free V/F setting, voltage.4
Free V/F setting, freq.5
b108
Free V/F setting, voltage.5
b109
Free V/F setting, freq.6
b110
Free V/F setting, voltage.6
b111
b112
Free V/F setting, freq.7
Free V/F setting, voltage.7
b113
"b" Function
Description
Selects when the fan is ON during
inverter operation, four options:
00...Fan is always ON
01...Fan is ON during run, OFF
during stop (5 minute delay
from ON to OFF)
02...Fan is temperature controlled
Two option codes:
00...Count
01...Clear
Select initialized parameters, four
option codes:
00...All parameters
01...All parameters except
in/output terminals and
communication.
02...Only registered parameters in
Uxxx.
03...All parameters except
registered parameters in Uxxx
and b037.
Three option codes:
00...Disable
01...Enable during run only
02...Enable always
Range is:
330 to 380V (200V class)
660 to 760V (400V class)
Set range, 0 ~ value of b102
Set range, 0 ~ 800V
Set range, value of b100 ~b104
Set range, 0 ~ 800V
Set range, value of b102 ~b106
Set range, 0 ~ 800V
Set range, value of b104 ~b108
Set range, 0 ~ 800V
Set range, value of b108 ~b110
Set range, 0 ~ 800V
Set range, value of b108 ~b112
Set range, 0 ~ 800V
Set range, b110 ~ 400
Set range, 0 ~ 800V
C−17
Run
Defaults
Mode
Lnitial data
Units
Edit
01
-
00
-
00
-
01
-
360/
V
720
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V
0.
Hz
0.0
V