Acceleration Stop/Deceleration Stop - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

3−30
Acceleration stop/Deceleration stop – The acceleration stop and deceleration stop
frequency setting allows you to make the inverter wait, upon starting the motor or upon
decelerating the motor, until the motor slip becomes less when the motor load causes a
large moment of inertia. Use this function if the inverter trips because of overcurrent
when starting or decelerating the motor. This function operates with every acceleration
and deceleration pattern, regardless the acceleration and deceleration curve selection
(A097 and A098). Instead of setting A069,A070,A154 and A155, acceleration and
deceleration can be held by intelligent input configured as "83:HLD".
Output frequency
A154
A069
A070
Func.
Code
Acceleration hold frequency
A069
Acceleration hold time
A070
Deceleration hold frequency
a154
Deceleration hold time
a155
A155
"A" Function
Name
Sets the frequency to hold
acceleration, range is 0.0 to
400.0Hz
Sets the duration of
acceleration hold, range is 0.0
to 60.0 seconds
Sets the frequency to hold
deceleration, range is 0.0 to
400.0Hz
Sets the duration of
deceleration hold, range is 0.0
to 60.0 seconds
Output frequency
t
HLD input
Description
Run
Defaults
Mode
Lnitial data
Units
Edit
0.00
Hz
0.0
sec.
0.0
Hz
0.0
sec.
t

Advertisement