Control Logic Signal Specifications

The control logic connectors are located just behind the front housing cover. The relay
contacts are just to the left of the logic connectors. Connector labeling is shown below.
Terminal Name
P24
PLC
1
2
3/GS1
4/GS2
5/PTC
6
7/EB
GS1(3)
GS2(4)
PTC(5)
EB(7)
EA
L (in upper row) *1
11/EDM
12
CM2
AM
EO
L (in bottom row) *2
OI
RS485
comm.
SN
Relay
contacts
SP EO
RS485
comm.
output
Description
+24V for logic inputs
Intelligent input common
Discrete logic inputs
(Terminal [3],[4],[5] and [7]
have dual function. See
following description and
related pages for the details.)
Safe stop input GS1
Safe stop input GS2
Motor thermistor input
Pulse train input B
Pulse train input A
GND for logic inputs
Discrete logic outputs [11]
(Terminal [11] has dual
function. See following
description and related pages
for the details.)
Discrete logic outputs [12]
GND for logic output
Analog voltage output
Pulse train output
GND for analog signals
Analog current input
Logic inputs
7
6
5
4
EA
H
O
Pulse
Pulse
Analog
Train
Train
input
input
24VDC, 100mA. (do not short to terminal L)
To change to sink type, remove the jumper
wire between [PLC] and [L], and connect it
between [P24] and [PLC]. In this case,
connecting [L] to [1]~[7] makes each input
ON. Please remove the jumper wire when
using external power supply.
27VDC max. (use PLC or an external supply
referenced to terminal L)
Functionality is based on ISO13849-1 *4
Connect motor thermistor between PTC and
L terminal to detect the motor temperature.
Set 19 in C005.
2kHz max.
Common is [PLC]
32kHz max.
Common is [L]
Sum of input [1]~[7] currents (return)
50mA max. ON state current,
27 VDC max. OFF state voltage
Common is CM2
In case the EDM is selected, the functionality
is based on ISO13849-1
4VDC max. ON state voltage depression
50mA max. ON state current,
27 VDC max. OFF state voltage
Common is CM2
100 mA: [11], [12] current return
0~10VDC 2mA maximum
10VDC 2mA maximum, 32kHz maximum
Sum of [OI], [O], and [H] currents (return)
4 to 19.6 mA range, 20 mA nominal,
input impedance 100 Ω
26
3
2
1
L
PLC
Jumper wire
OI
L
AM CM2
12
Logic
Analog
output
output
Ratings
P24
11

Hide quick links: