Hitachi WJ200 Series Instruction Manual page 390

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Func.
Name
Code
[OI] input active range start
A103
current
[OI] input active range end
A104
current
[OI] input start frequency
A105
select
Acceleration curve constant
a131
Deceleration curve constant
a132
A input select for calculate
A141
function
B input select for calculate
A142
function
Calculation symbol
A143
ADD frequency
A145
ADD direction select
A146
Curvature of EL-S-curve at
a150
the start of acceleration
"A" Function
Description
The starting point (offset) for
the current input range,
range is 0. to 100.%
The ending point (offset) for the
current input range,
range is 0. to 100.%
Two options; select codes:
00...Use offset (A101 value)
01...Use 0Hz
Range is 01 to 10.
Range is 01 to 10.
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Calculates a value based on the
A input source (A141 selects)
and B input source (A142
selects).
Three options:
00...ADD (A input + B input)
01...SUB (A input - B input)
02...MUL (A input * B input)
An offset value that is applied
to the output frequency when
the [ADD] terminal is ON.
Range is 0.0 to 400.0 Hz
Two options:
00...Plus (adds A145 value to
the output frequency
setting)
01...Minus (subtracts A145
value from the output
frequency setting)
Range is 0 to 50%
Run
Defaults
Mode
Lnitial data
Units
Edit
20.
%
100.
%
00
02
02
02
03
00
0.00
Hz
00
10.
%
C−9

Advertisement

Table of Contents
loading