Recommended Ferrule; How To Connect? - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Recommended ferrule

For safe wiring and reliability, it is recommended to use following ferrules.
Wire size
Model name of
2
mm
(AWG)
0.25 (24)
AI 0.25-8YE
0.34 (22)
AI 0.34-8TQ
0.5 (20)
AI 0.5-8WH
0.75 (18)
AI 0.75-8GY
* Supplier: Phoenix contact
Crimping pliers: CRIPMFOX UD 6-4 or CRIMPFOX ZA 3

How to connect?

(1) Push down an orange actuating lever by a slotted screwdriver (width 2.5mm max.).
(2) Plug in the conductor.
(3) Pull out the screwdriver then the conductor is fixed.
2.5mm
L [mm]
ferrule *
12.5
12.5
14
14
Push down an
orange actuating
lever.
Φd [mm]
ΦD [mm]
0.8
2.0
0.8
2.0
1.1
2.5
1.3
2.8
Plug in the
conductor.
4−9
Φ d
8
L
Φ D
Pull out the
screwdriver to fix
the conductor.

Advertisement

Table of Contents
loading

Table of Contents