Hitachi WJ200 Series Instruction Manual page 367

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

B−38
Register
No.
1345h to
(Reserved)
1348h
1349h
Operation level at O disconnection
134Ah
Operation level at OI disconnection
134Bh to
(reserved)
134Dh
134Eh
Ambient temperature
134Fh to
(reserved)
1350
Cumulative input power data
1351h
clearance
1352h
Watt-hour display gain
1353h to
(Reserved)
1354h
1355h
Start frequency
1356h
Carrier frequency
Initialization mode (parameters or
1357h
trip history)
1358h
Country code for initialization
Frequency scaling conversion
1359h
factor
135Ah
STOP key enable
135Bh
Restart mode after FRS
Automatic
135Ch
reduction
135Dh
Dynamic braking usage ratio
135Eh
Stop mode selection
135Fh
Cooling fan control
1360h
Clear elapsed time of cooling fan
1361h
Initialization target data
1362h
Dynamic braking control
1363h
Dynamic braking activation level
1364h to
(Reserved)
1366h
1367h
Free-setting V/f frequency (1)
1368h
Free-setting V/f voltage (1)
1369h
Free-setting V/f frequency (2)
136Ah
Free-setting V/f voltage (2)
136Bh
Free-setting V/f frequency (3)
136Ch
Free-setting V/f voltage (3)
136Dh
Free-setting V/f frequency (4)
136Eh
Free-setting V/f voltage (4)
136Fh
Free-setting V/f frequency (5)
1370h
Free-setting V/f voltage (5)
1371h
Free-setting V/f frequency (6)
1372h
Free-setting V/f voltage (6)
1373h
Free-setting V/f frequency (7)
1374h
Free-setting V/f voltage (7)
Function
Function name
carrier
frequency
R/W
Monitoring and setting items
code
-
-
-
b070
R/W
0. to 100. (%) or "no" (ignore)
b071
R/W
0. to 100. (%) or "no" (ignore)
-
-
-
b075
R/W
-10 to 50
-
-
-
b078
R/W
Clearance by setting "1"
b079
R/W
1 to 1000
-
-
-
b082
R/W
10 to 999
b083
R/W
20 to 150
0,1 (clearing the trip history), 2 (initializing
the data), 3 (clearing the trip history and
b084
R/W
initializing the data), 4 (clearing the trip
history and initializing the data and EzSQ
program)
b085
R/W
0 (area A), 1 (area B)
b086
R/W
1 to 9999
0 (enabling), 1 (disabling), 2 (disabling only
b087
R/W
stop)
0 (starting with 0 Hz), 1 (starting with
b088
R/W
matching frequency), 2 (starting with active
matching frequency)
0(disabling)/1(enabling(
b089
R/W
controlled))/
2(enabling( fin temperature controlled))
b090
R/W
0 to 1000
b091
R/W
0 (deceleration until stop), 1 (free-run stop)
0 (always operating the fan), 1 (operating the
b092
R/W
fan only during inverter operation [including 5
minutes after power-on and power-off]) ,2
b093
R/W
0(count)/1(clear)
b094
R/W
0 to 3
0 (disabling), 1 (enabling [disabling while the
b095
R/W
motor is stopped]), 2 (enabling [enabling also
while the motor is stopped])
b096
R/W
330 to 380, 660 to 760
-
-
-
b100
R/W
0. to "free-setting V/f frequency (2)"
b101
R/W
0. to 8000
b102
R/W
0. to "free-setting V/f frequency (3)"
b103
R/W
0. to 8000
b104
R/W
0. to "free-setting V/f frequency (4)"
b105
R/W
0. to 8000
b106
R/W
0. to "free-setting V/f frequency (5)"
b107
R/W
0. to 8000
b108
R/W
0. to "free-setting V/f frequency (6)"
b109
R/W
0. to 8000
b110
R/W
0. to "free-setting V/f frequency (7)"
b111
R/W
0. to 8000
b112
R/W
0. to 400.
b113
R/W
0. to 8000
Data
resolution
1 [%]
1 [%]
-
1 [℃]
-
-
1
-
0.01 [Hz]
0.1 [kHz]
-
-
0.01
-
-
output
current
-
0.1 [%]
-
-
-
-
1. [V]
-
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]