Explanation Of Functions; S-Curve Acceleration And Deceleration For Elevator (El S-Curve) - Hitachi SJ300-EL Series Instruction Manual Supplement

Inverter for elevator applications three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ300-EL Series:
Table of Contents

Advertisement

2.

Explanation of Functions

2.1

S-curve acceleration and deceleration for elevator (EL S-curve)

Output
Frequency
f-max
(A)
(B)
Shape of curve portions (A) to (D) above can be adjusted separately, as shown in the following table.
Setting value is a % of target frequency.
<Setting items>
Function
Function Name
Code
A097
Acceleration
selection
A098
Deceleration
selection
P060
Curve ratio 1 during
acceleration
P061
Curve ratio 2 during
acceleration
P062
Curve ratio 1 during
deceleration
P063
Curve ratio 2 during
deceleration
(Note 1) A linear characteristic will result (A097 = A098=00) if 0% is set for the curve ratio.
(Note 2) A linear characteristic will result if the change of the target speed is less than or equal
to 10% of the maximum frequency.
(Note 3) All of the curve constants are ignored if "04" is selected in A097 and A098. Refer to the
manual for standard S-curve acceleration & deceleration description.
(Note 4) The S-curve will be recalculated if the target speed is changed while accelerating or
decelerating. Therefore do not use analog signals for the target speed.
(Note 5) Curve ratio for acceleration/deceleration must be in the range of 10% up to 50%.
Acc.time
(F002)
Setting Range
pattern
Select "04"
pattern
Select "04"
0. – 50 (%)
0. – 50 (%)
0. – 50 (%)
0. – 50 (%)
9
Chapter 2 – Explanation of Functions
Dec. time
(F003)
Remarks
Portion (B)
Portion (A)
Portion (C)
Portion (D)
(C)
(D)
time