Configuration Using the Web Interface

Warning

The ES8509-XT provides several types of warning features for you to remotely monitor the status of the
attached devices or changes in your network. The features include Fault Relay, System Log and SMTP Email
Alert.
The following web pages are included in this group:

Fault Relay

Event Selection
on Page 116
SysLog Configuration
SMTP Configuration
Optionally, you can use the CLI for configuration, see
Fault Relay
The ES8509-XT provides one alarm relay output (DO) that can support multiple fault conditions. The relay
contacts are energized (open) for normal operation and close under fault conditions. The fault conditions
include power failure, Ethernet port link faults, Ring topology changes, Ping failures, DI state changes or ping
remote IP address failure.The Relay 1 field shows the current state of the relay. If the relay is triggered, the
event type is marked with an asterisk (*). The above image shows that a power event occurred.
The following table describes Fault Relay conditions:
Fault Relay
This displays whether the Relay status is on or off. You must select a fault relay
Relay 1
option and click Apply for the status to display as on.
Power
Detects power input status on DC1, DC2, or both power sources.
Port Link
Monitors port link down events for the selected ports.
Ring
Monitors ring topology changes.
Ping
If the target IP address does not reply to the ping request, the fault relay is enabled.
114 - Warning
on Page 117
on Page 118
Warnings (CLI)
on Page 178.