Warning

The ES7506 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log and SMTP Email Alert.
The following web pages are included in this group:

Fault Relay

Event Selection
on Page 83
SysLog Configuration
SMTP Configuration
Optionally, you can use the CLI for configuration, see
Fault Relay
The ES7506 provides one digital output (Relay Output). The relay
contacts are energized (open) for normal operation and close under
fault conditions. Fault conditions include Power Failure, Ethernet
Port Link Failure, Ping Failure, and Ring Topology Change. You can
enable and select relay trigger by clicking the Apply button.
Relay 1: Enable the Relay 1 box, and then select the Event Type and its
parameters.
Event Type: You are given the following options: Dry Output, Power
Failure, Link Failure, Ping Failure, and Super Ring Failure. Each
event type has its own parameters and is configurable. Each Relay
can have one event type.
Event Type: Dry Output
On Period (Sec): Enter the amount of time you would like the Relay
Output to be on. This can range from 0-4294967295 seconds.
Off Period (Sec): Enter the amount of time you would like the Relay
Output to be off. This can range from 0-4294967295 seconds.
When the amount of time is reached, the ES7506 turns the Relay
Output on or off.
Event Type: Power Failure
Power ID: Select either Power 1 or Power 2. When power is shut
down, the ES7506 shorts the Relay Out and the DO LED lights.
RocketLinx ES7506 User Guide: 2000529 Rev. F
on Page 84
on Page 85
Configuration Using the Web Interface
Warnings (CLI)
on Page 136.
Warning - 81