Map 0000: Start Map - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 4: Event Codes and Associated Maintenance Action (Continued)
Event
Code
585
586
810
811

MAP 0000: Start MAP

This MAP describes initial fault isolation for the Edge Switch 2/24. Fault isolation
begins at the High Availability Fabric Manager (HAFM) server, failed switch,
Internet-connected personal computer (PC) running the Embedded Web Server
(EWS) interface, or attached host.
1
Prior to fault isolation, acquire the following information from the customer:
Edge Switch 2/24 Service Manual
Explanation
Primitive sequence timeout.
Invalid primitive sequence
received for current link state.
High temperature warning
(CTP thermal sensor).
Critically hot temperature
warning (CTP thermal sensor).
A system configuration drawing or planning worksheet that includes the
HAFM server, switch, other HP products, and device connections.
The location of the HAFM server and all switches.
The internet protocol (IP) address, gateway address, and subnet mask for the
switch reporting the problem.
If performing fault isolation using the HAFM server:
— The Windows NT user name and password. These are required when
prompted during any MAP or repair procedure that directs the HAFM
server to be rebooted.
— The user name, maintenance password, and HAFM server name. All are
case sensitive and required when prompted at the HAFM Login dialog
box.
If performing fault isolation using a customer-supplied server:
Action
Go to
MAP 0600: Port Failure and
Link Incident
Analysis.
Go to
MAP 0600: Port Failure and
Link Incident
Analysis.
Go to
MAP 0500: FRU Failure
Analysis.
Go to
MAP 0500: FRU Failure
Analysis.
Diagnostics
33