Diagnostics
Does the switch appear powered on?
YES
2
Was an event code 400, or 411, or 413 observed at the Edge Switch 2/24 Event
Log or at the EWS Event Log?
YES
3
Table 6
that describe fault isolation procedures.
Table 6: MAP 200: Event Codes
Event
Code
400
411
4
POST/IPL diagnostics detected a FRU failure as indicated by an event code 400
with supplementary event data.
1. At the Hardware View, click Logs and select Event Log. The Event Log
2. Examine the first two bytes (0 and 1) of event data.
3. Byte 0 is a FRU code that indicates the failed component. Byte 1
64
NO
An AC power distribution problem is indicated, and analysis for the
failure is not described in this MAP. Go to
Distribution
NO
Analysis for the failure is not described in this MAP. Go to
0000: Start
MAP" on page 33. Exit MAP.
lists event codes, brief explanations of the codes, and the associated steps
Power-up diagnostic failure.
Firmware fault.
displays.
is the slot number of the failed FRU (00 for a nonredundant FRU, and 00 or
01 for redundant FRUs).
Table 7
lists byte 0 FRU codes and associated steps that describe fault
isolation procedures.
page 54
Analysis" on
Explanation
"MAP 0100: Power
. Exit MAP.
Action
Go to
step
4.
Go to
step
7.
Edge Switch 2/24 Service Manual
"MAP