HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 45

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

27
Inspect the switch for indications of being powered on, such as:
Does the switch appear powered on?
YES
A faulty power LED is indicated, but switch and Fibre Channel port operation is
not disrupted. The LED is connected to the circuitry in a fan module, and the
power supply module must be removed and replaced (See
Power
28
Is the system error LED (amber) at the switch front bezel blinking?
YES
29
Unit beaconing is enabled for the switch.
1. Consult the customer and next level of support to determine the reason unit
2. Disable unit beaconing.
Edge Switch 2/24 Service Manual
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
Audio emanations and airflow from cooling fans.
NO
A power distribution problem is indicated. Go to
event codes. If no event codes are found, go to
Distribution
Supply" on page 179.) Exit MAP.
NO
Go to
step
30.
beaconing is enabled.
a. At the Hardware View, right-click the front bezel graphic (away from a
FRU). A pop-up menu displays.
b. Click the Enable Unit Beaconing option. The check mark disappears
from the box adjacent to the option, and unit beaconing is disabled.
page 54
Analysis" on
step 21
"MAP 0100: Power
. Exit MAP.
"RRP 2: Redundant
Diagnostics
to obtain
45