HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 57

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

5
Ensure the indicated power supply is correctly installed and seated in the switch.
If required, partially remove and reseat the power supply.
Was a corrective action performed?
YES
6
Verify redundant power supply operation.
1. Inspect the power supply and verify all amber LEDs are extinguished.
2. At the Hardware View, observe the graphic representing the power supply
Is a failure indicated?
YES
7
A redundant power supply failed and must be removed and replaced (See
Redundant Power
Did power supply replacement solve the problem?
NO
Contact the next level of support. Exit MAP.
8
Power sense circuitry is defective in the indicated power supply or there is a
problem with facility input power.
Edge Switch 2/24 Service Manual
NO
Go to
step
7.
and ensure a failure symbol (blinking red and yellow diamond) does not
appear.
NO
The switch appears operational. Exit MAP.
Supply" on page 179).
This procedure is concurrent and can be performed while switch power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
YES
The switch appears operational. Exit MAP.
Diagnostics
"RRP 2:
57