HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 40

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
16
A green circle displays as the background to the icon representing the switch
reporting the problem. Although the switch is operational, a minor problem may
exist.
Double-click the icon representing the switch reporting the problem. The
Hardware View displays. At the Hardware View:
Does a yellow triangle overlay the switch or FRU graphic?
YES
17
Beaconing is enabled for the FRU.
1. Consult the customer and next level of support to determine the reason FRU
2. Disable FRU beaconing.
Was FRU beaconing enabled because a FRU failure or degradation was
suspected?
YES
Go to
18
Does a yellow triangle (attention indicator) overlay a port graphic?
YES
40
Inspect the switch for a yellow triangle that overlays the FRU graphic and
indicates FRU beaconing is enabled.
Inspect ports for a yellow triangle (attention indicator) that overlays the port
graphic.
NO
Go to
step
18.
beaconing is enabled.
a. At the Hardware View, right-click the FRU graphic. A pop-up menu
displays.
b. Click the Enable Beaconing option. The check mark disappears from the
box adjacent to the option, and FRU beaconing is disabled.
NO
The switch appears operational. Exit MAP.
step
2.
NO
Go to
step
20.
Edge Switch 2/24 Service Manual

Advertisement