HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 106

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
Did the link incident recur?
YES
Contact the next level of support. Exit MAP.
31
The switch port reporting the problem is causing the recurrent link incident. The
recurring link incident indicates port degradation and a possible pending failure.
Go to step 6.
32
Does the EWS interface appear operational?
NO
33
A Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or other similar message displays. The
message indicates the Web browser PC cannot communicate with the switch
because:
Continue.
34
Ensure the switch reporting the problem is connected to facility AC power.
Inspect the switch for indications of being powered on, such as:
106
NO
The attached device, Fibre Channel link, and switch appear
operational. Exit MAP.
YES
Go to
step
36.
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP failed.
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
Audio emanations and airflow from cooling fans.
Edge Switch 2/24 Service Manual