HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 259

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 75: Event Code 440
Message:
Embedded port hardware failed.
Severity:
Major.
Explanation:
The embedded port hardware detected a fatal CTP error.
Action:
Replace the switch.
Event Data:
Byte 0 = CTP slot position (00).
Byte 1 = engineering reason code
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
Table 76: Event Code 442
Message:
Embedded port anomaly detected.
Severity:
Informational.
Explanation:
The switch detected a deviation in the normal operating mode or status of the
embedded port.
Action:
No action required. An additional event code is generated if this incident exceeds
an error threshold or results in a port failure.
Event Data:
Byte 0 = port number.
Byte 1 = engineering reason code.port.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Server
System
Event
Error
Log
LED
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
257

Advertisement

Table of Contents
loading

Table of Contents