Diagnostics
Did the operating parameter change solve the problem and did both switches join
through the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
15
A switch E_Port segmented because two fabric elements had duplicate domain
IDs.
1. Work with the system administrator to determine the desired domain ID (1
2. Notify the customer that both switches will set offline. Ensure the system
3. Set both switches offline
4. At the Hardware View for the first switch reporting the problem, click
5. Type the customer-determined preferred domain ID value, then click
6. Repeat steps 4 and 5 at the Hardware View for the switch attached to the
7. Set both switches online
Did the domain ID change solve the problem and did both switches join through
the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
114
YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
through 31 inclusive) for each switch.
administrator quiesces Fibre Channel frame traffic through the switch and sets
attached devices offline.
Configure and select Operating Parameters. The Configure Operating
Parameters dialog box displays.
Activate.
segmented E_Port (second switch). Use a different preferred domain ID
value.
YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
("Set the Switch Online or
("Set the Switch Online or
Offline" on page 150).
Offline" on page 150).