Diagnostics
11
As indicated by an event code 063, the fabric controller software detected a fabric
element (switch or switch) in a multiswitch fabric that has more than 32 ISLs
attached. Fibre Channel frames may be lost or routed in loops because of potential
fabric routing problems.
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so that no switch or switch elements have more than 32
ISLs.
Did fabric reconfiguration solve the problem?
NO
Contact the next level of support. Exit MAP.
12
A 070 event code indicates an E_Port detected an incompatibility with an attached
switch and prevented the switches from forming a multiswitch fabric. A
segmented E_Port cannot transmit Class 2 or Class 3 Fibre Channel traffic.
A 071 event code indicates the switch is isolated from all switches in a
multiswitch fabric, and is accompanied by a 070 event code for each segmented
E_Port. The 071 event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
1. At the Hardware View, click Logs and select Event Log. The Event Log
2. Examine the first five bytes (0 through 4) of event data.
3. Byte 0 specifies the switch port number (00 through 139) of the segmented
Table 17: Byte 4, Segmentation Reasons and Actions
Byte 4
01
02
03
112
YES
The switch and multiswitch fabric appear operational.
Exit MAP.
displays.
E_Port. Byte 4 specifies the segmentation reason
Segmentation Reason
Incompatible operating
parameters.
Duplicate domain IDs.
Incompatible zoning
configurations.
(Table
17).
Action
Go to
step
14.
Go to
step
15.
Go to
step
16.
Edge Switch 2/24 Service Manual