Was port beaconing enabled because port failure or degradation was suspected?
YES
Go to
16
The port has an invalid attachment. The information in the Port Properties dialog
box specifies the reason
Table 13: Port Properties, Invalid Attachment Reasons and Actions
Unknown.
ISL connection not allowed on this port.
Incompatible switch at other end of ISL.
External loopback adapter connected to the port.
N-Port connection not allowed on this port.
Non-HP switch at other end of the ISL.
Port binding violation - Unauthorized WWN.
Unresponsive node connected to port.
17
The port connection conflicts with the configured port type. Either an expansion
port (E_Port) is incorrectly cabled to a Fibre Channel device, or a fabric port
(F_Port) is incorrectly cabled to a fabric element (director or switch).
1. At the HAFM server's Hardware View for the selected switch, click
2. Use the vertical scroll bar as necessary to display the information row for the
3. Select (click) the Type field and configure the port from the list box as
Edge Switch 2/24 Service Manual
NO
The switch appears operational. Exit MAP.
step
1.
Reason
Configure and select Ports. The Configure Ports dialog box displays.
port indicating an invalid attachment.
follows:
a. Select fabric port (F_Port) if the port is cabled to a device (node).
b. Select expansion port (E_Port) if the port is cabled to a fabric element
(switch or switch) to form an ISL.
(Table
13).
Diagnostics
Action
Contact the next level of
support.
Go to
step
17.
Go to
step
18.
Go to
step
19.
Go to
step
17.
Go to
step
18.
Go to
step
21.
Go to
step
22.