Did the HAFM server (or customer-supplied server) reconfigure as a client and
did the Ethernet connection recover?
NO
Contact the next level of support. Exit MAP.
21
The IP address defining the switch to the HAFM application is incorrect or
unknown and must be verified. A maintenance terminal (PC) and asynchronous
RS-232 null modem cable are required to verify the switch IP address. The tools
are provided with the switch or by service personnel. To verify the IP address:
1. Remove the protective cap from the 9-pin maintenance port at the rear of the
2. Connect the other cable end to a 9-pin communication port (COM1 or
3. Power on the maintenance terminal. After the PC powers on, the Windows
4. At the Windows desktop, click the Windows Start button. The Windows
Note:
serial communication software.
5. At the Windows Workstation menu, sequentially select Programs >
Edge Switch 2/24 Service Manual
YES
The switch-to-server connection is restored and the second HAFM
server (or customer-supplied server) appears operational as a client.
Exit MAP.
switch (a Phillips-head screwdriver may be required). Connect one end of the
RS-232 null modem cable to the port.
COM2) at the rear of the maintenance terminal PC.
desktop displays.
Workstation menu displays.
The following steps describe inspecting the IP address using HyperTerminal
Accessories > HyperTerminal. The Connection Description dialog box
displays.
Diagnostics
81