Does the switch appear powered on?
YES
35
Inspect Fibre Channel port operational states at the EWS interface.
1. At the View panel, click the Port Properties tab. The View panel (Port
2. Click the port number (0 through (139) for which a failure is suspected to
3. Inspect the Operational State field. Scroll down the View panel as
4.
Table 14: MAP 600: Port Operational States and Actions
Operational
Offline
Not Operational
Port Failure
Testing
Invalid
Attachment
Link Reset
Not Installed
Edge Switch 2/24 Service Manual
NO
Analysis for an Ethernet link, AC power distribution, or CTP failure
is not described in this MAP. Go to
page 33. If this is the second time at this step, contact the next level of
support. Exit MAP.
Properties tab) displays with port 0 highlighted in red.
display properties for that port.
necessary.
Table 14
lists port operational states and associated MAP 0600 steps that
describe fault isolation procedures.
State
Go to
Go to
Go to
Internal or external loopback test in process.
Exit MAP.
Go to
Go to
Go to
Action
step
14.
step
14.
step
6.
step
16.
step
24.
step
36.
"MAP 0000: Start
MAP" on
Diagnostics
107