23
Inspect and service the host bus adapters (HBAs), as necessary.
Did service of the HBAs solve the problem?
NO
Contact the next level of support. Exit MAP.
24
The switch and attached device are performing a Fibre Channel link reset. This is
a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO
Go to
25
A link incident message appeared in the Link Incident Log or in the Link
Incident field of the Port Properties dialog box; or an event code 581, 582, 583,
584, 585, or 586 was observed at the console of an OSI server attached to the
switch reporting the problem.
Clear the link incident for the port.
1. At the Hardware View, right-click the port. A pop-up menu displays.
2. Select Clear Link Incident Alert(s). The Clear Link Incident Alert(s)
Figure 24: Clear Link Incident alert(s)
Edge Switch 2/24 Service Manual
YES
Exit MAP.
YES
The Fibre Channel link and switch appear operational. Exit MAP.
step
1.
dialog box displays
(Figure
24).