Table 31: Event Code 052
Message:
Management Server internal error, asynchronous status report activation, or mode
register update occurred.
Severity:
Informational.
Explanation:
An internal operating error was detected by the Management Server subsystem, an
asynchronous status was reported to an attached host, or a mode register update
occurred.
Action:
Management Server internal error: Perform the data collection procedure and
return the Zip disk to Hewlett-Packard support personnel.
Asynchronous status report activation: No action required.
Mode register update: No action required.
Event Data:
Supplementary data consists of reporting tasks of type eMST_SB2, with
component_id eMSCID_SB2_CHPGM. For each type of error or indication, the
subcomponent_id is:
Management Server internal error: subcomponent_id is
eMS_ELR_SB2_DEVICE_PROTOCOL_ERROR or
eMS_ELR_SB2_MSG_PROCESSING_ERROR.
Asynchronous status report activation: subcomponent_id is
eSB2_CP_RER_ASYNCH_STATUS_REPORTING.
Mode register update: subcomponent_id is eMS_ELR_MODE_REGISTER_UPDATE.
Distribution: