Diagnostics
3. Select the This port (n) only radio button (where n is the port number) and
4. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
26
Inspect the fiber-optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
1. Notify the customer the port will be blocked. Ensure the customer's system
2. Block the port
3. Remove and replace the fiber-optic jumper cable.
4. Unblock the port
Was a corrective action performed?
YES
27
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
104
click OK. The link incident clears.
NO
The problem is transient and the Fibre Channel link and switch
appear operational. Exit MAP.
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
("Block and Unblock
("Block and Unblock
NO
Go to
step
28.
NO
The Fibre Channel link and switch appear operational.
Exit MAP.
Ports" on page 152).