HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 258

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Codes
Table 73: Event Code 426
Message:
Multiple ECC single-bit errors occurred.
Severity:
Minor.
Explanatio
When the SDRAM controller detects an error checking and correction (ECC) error, an
n:
interrupt occurs. If an interrupt occurs a certain number of times weekly, a 426 event
code is recorded. The number of interrupts is indicated by the event data.
Action:
No action required. SDRAM is probably malfunctioning intermittently.
Event Data:
Byte 0 of the event data (equal to 5, 10, 15, or 20) is recorded. The number of
interrupts equals two to the power of the event data. Event data equal to 10 indicates
1,024 ECC error interrupts.
Distribution
Switch
:
EWS
Event Log
Table 74: Event Code 433
Message:
Non-recoverable Ethernet fault.
Severity:
Major.
Explanation:
A non-recoverable Ethernet interface failure was detected and the LAN connection
to the HAFM server or Internet was terminated. No failure information or event
codes are reported outside the switch. Although Fibre Channel port functionality is
not affected, the switch cannot be monitored or configured.
Action:
Replace the switch.
Event Data:
Byte 0 = LAN error type as follows: 01 = hard failure, 04 = registered fault.
Byte 1 = LAN error subtype (internally defined).
Byte 2 = LAN fault identifier (internally defined).
Distribution:
Switch
EWS
Event
Log
256
HAFM Server
System
Event Log
Error LED
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call-Home