HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 111

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

8
A minor error occurred that caused the management server database to be
re-initialized to an empty state. As a result, a disruptive server logout and login
occurred for all attached devices. The following list explains the errors.
All attached devices resume operation after management server login. Perform the
data collection procedure and return the Zip disk to HP for analysis. Exit MAP.
9
A minor error occurred that caused the fabric controller database to be
re-initialized to an empty state. As a result, the switch briefly lost interswitch link
capability. The following explains the error.
All interswitch links resume operation after CTP reset. Perform the data collection
procedure and return the Zip disk to HP for analysis. Exit MAP.
10
As indicated by an event code 062, the fabric controller software detected a path
to another switch (or fabric element) in a multiswitch fabric that traverses more
than three interswitch links (hops). Fibre Channel frames may persist in the fabric
longer than timeout values allow.
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so the path between any two fabric elements does not
traverse more than three hops.
Did fabric reconfiguration solve the problem?
NO
Contact the next level of support. Exit MAP.
Edge Switch 2/24 Service Manual
Event code 051 - The management server database failed CRC validation.
Event code 052 - An internal operating error was detected by the
management server subsystem.
Event code 061 - The fabric controller database failed CRC validation.
YES
The switch and multiswitch fabric appear operational.
Exit MAP.
Diagnostics
111

Advertisement

Table of Contents
loading