Diagnostics
Does the Operational State field indicate Segmented E_Port?
YES
6
Inspect the Segmentation Reason field at the Port Properties dialog box.
Table 16
isolation procedures.
Table 16: Port Segmentation Reasons and Actions
Incompatible operating parameters.
Duplicate domain IDs.
Incompatible zoning configurations.
Build fabric protocol error.
No principal switch.
No response from attached switch.
ELP retransmission failure timeout
7
A minor error occurred that caused the fabric services database to be re-initialized
to an empty state. As a result, a disruptive fabric logout and login occurred for all
attached devices. The following list explains the errors.
All attached devices resume operation after fabric login. Perform the data
collection procedure and return the Zip disk to HP for analysis. Exit MAP.
110
NO
Analysis for other link incident is not described in this MAP. Go to
"MAP 0600: Port Failure and Link Incident
Exit MAP.
lists port segmentation reasons and associated steps that describe fault
Segmentation Reason
Event code 011 - The login server database failed cyclic redundancy check
(CRC) validation.
Event code 021 - The name server database failed CRC validation.
page 92
Analysis" on
Action
Go to
step
14.
Go to
step
15.
Go to
step
16.
Go to
step
17.
Go to
step
19.
Go to
step
20.
Go to
step
21.
Edge Switch 2/24 Service Manual
.