Event Codes
Table 86: Event Code 523
Message:
FL_Port open request failed.
Severity:
Informational.
Explanation:
When the indicated FL_Port attempted to open a loop device, the port open (OPN)
sequence was returned.
Action:
No action required.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = arbitrated loop physical address (AL_PA) of the device transmitting the
OPN sequence.
Distribution:
Switch
EWS
Event
Log
Table 87: Event Code 524
Message:
No AL_PA acquired.
Severity:
Informational.
Explanation:
Switch cannot allocate an AL_PA of 0 (loop master) for an FC-AL device during
loop initialization. The device cannot participate in loop operation.
Action:
Disconnect the FC-AL device that is loop master.
Event Data:
Byte 0 = port number (00 through 23).
Distribution:
Switch
EWS
Event
Log