Summary of Contents for Intel SR9000MK4U - Server System - 0 MB RAM
Page 1
® Intel Server System SR9000MK4U Product Guide Intel Order Number D71314-004...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor...
Page 4
Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. ® Intel Server System SR9000MK4U Product Guide...
Page 5
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR9000MK4U Product Guide...
Page 6
® Intel Server System SR9000MK4U Product Guide...
Preface About this Manual ® Thank you for purchasing and using Intel server products. This manual is written for system technicians who are responsible for troubleshooting, ® upgrading, and managing the Intel Server System SR9000MK4U. This document provides an overview of the features of the server system utilities, and instructions on how to install, setup, and manage the system.
Processor, memory DIMMs, hard drive, USB floppy drive, CD-ROM or DVD-ROM drive, RAID controller, operating system. For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SR9000MK4U/ compat.htm.
Page 9
Operating System Driver (for operating system drivers) For firmware and BIOS Firmware Updates updates, or for BIOS recovery For diagnostics test Diagnostics software See also the Resource CD that came with your server system. ® Intel Server System SR9000MK4U Product Guide...
When the system power is forced off, either the power button or the IPMI “Power On” command must be used to power the system back on. ® Intel Server System SR9000MK4U Product Guide...
Powering the System On and Off ..................x Powering On the System Power ..................x Powering Off the System Power ..................x ® Chapter 1: Intel Server System SR9000MK4U Chassis Overview ....... 1 Chassis Description ....................... 2 External Chassis Features .....................3 Chassis Front ........................
Page 12
Installing and Removing the Hard Drive Backplane Cover ..........87 Removing the Hard Drive Backplane Cover ............... 87 Installing the Hard Drive Backplane Cover ..............88 Installing and Removing the KVM Card ................89 ® Intel Server System SR9000MK4U Product Guide...
Page 13
Navigating Setup Utility Screens ................146 Primary Screens ......................146 Configuring Serial-Over LAN .....................151 Chapter 5: Troubleshooting .................. 153 Initial Troubleshooting Steps .....................153 Collecting System State Information ..................156 How to Read the POST Codes ..................159 ® Intel Server System SR9000MK4U Product Guide xiii...
Page 14
Handhabung von Geräten ..................204 Warnungen zu Netzspannung und Elektrizität ............204 Warnhinweise für den Systemzugang ............... 205 Warnhinweise für Racks ................... 206 Elektrostatische Entladungen (ESD) ................. 206 Andere Gefahren ....................... 207 Français ..........................208 ® Intel Server System SR9000MK4U Product Guide...
Page 15
Europe (CE Declaration of Conformity) ..............232 VCCI (Japan) ......................232 BSMI (Taiwan) ......................233 RRL (Korea) ......................233 CNCA (CCC China) ....................233 Regulated Specified Components ..................234 Restriction of Hazardous Substances (RoHS) Compliance ..........235 End of Life / Product Recycling ..................235 ® Intel Server System SR9000MK4U Product Guide...
Page 16
® Intel Server System SR9000MK4U Product Guide...
Page 17
List of Figures ® Figure 1. Intel Server System SR9000MK4U Three Dimensional View........1 Figure 2. Chassis Front View ....................4 Figure 3. Front Panel Controls and Indicators................5 Figure 4. Optical Drive Bracket with Drive Installed ..............6 Figure 5. Hard Drive Carrier ...................... 6 Figure 6.
Page 18
Figure 86. Setting the Power Supply Support into Place ............85 Figure 87. Tightening the Power Supply Support Screws ............86 Figure 88. Removing the Hard Drive Backplane Cover ............87 Figure 89. Installing the Hard Drive Backplane Cover ............88 ® xviii Intel Server System SR9000MK4U Product Guide...
Page 19
Figure 133. FWUPDATE Execution Screen................144 Figure 134. State Transition Diagram ................... 156 Figure 135. Location of POST Code LED ................159 Figure 136. Connections Near Power Supply Box and PCI Card Divider ......168 ® Intel Server System SR9000MK4U Product Guide...
Page 20
Figure 141. Caution: Server System is Heavy ..............194 Figure 142. Caution: System Contains Areas of High Voltage ..........194 Figure 143. Warning: Voltage on Non Hot-swap Power Supply ........... 195 Figure 144. Warning: Voltage on Hot-swap Power Supply........... 195 ® Intel Server System SR9000MK4U Product Guide...
Page 21
Table 31. POST Codes Generated by the BMC and Logged at the Seven Segment LED ...171 Table 32. POST Codes Generated by SAL and Logged at the Seven Segment LED ..177 Table 33. Error POST Codes Generated by SAL ..............179 ® Intel Server System SR9000MK4U Product Guide...
Page 22
® xxii Intel Server System SR9000MK4U Product Guide...
Server System SR9000MK4U as shown in Figure 1 is a compact, high-density ® ® rack-mount server system with support for up to four Intel Itanium 2 processors and 256-GB DDR2 SDRAM memory. The system is based on the Hitachi CF-3e board set and the Hitachi CF-3e chipset.
Remote diagnostics support across the LAN • Remote KVM across the LAN • Remote optical drive access across the LAN • ® ® Upgrades Field upgradeable to the next generation Intel Itanium processor family • Multi-generational chassis ® Intel Server System SR9000MK4U Product Guide...
Front Panel, see “Front Panel” Memory box 1 Optical Drive Memory box 2 Hard Drives, HDD0 - HDD7 from left to right Memory box 3 Memory box 0 Figure 2. Chassis Front View ® Intel Server System SR9000MK4U Product Guide...
Orange blink: Non-critical fault other than power or cooling fault detected. – Off: No general fault detected. System diagnostic interrupt (SDINT) button: Asserts INIT to system. Figure 3. Front Panel Controls and Indicators ® Intel Server System SR9000MK4U Product Guide...
The system power must be turned off to remove or install this drive. AF001084 Figure 4. Optical Drive Bracket with Drive Installed ® Note: Intel validates specific DVD-ROM / CD-ROM drives. See the Intel Server System SR9000MK4U Tested Hardware and Operating System List” for a list of these drives available.
Watch for the LED status to change. The red LED should be on for 0.5 seconds, then the green turns on and remains on. • Intel validates specific hard drive types in the Server System SR9000MK4U. See the ® Intel Server System SR9000MK4U Tested Hardware and Operating System List for a list of the drives supported.
No error has been detected on the memory box or the memory box is powered off. No LED Hot-swap button. Press this button to initiate a hot-swap process. Figure 6. Memory Box Front View ® Intel Server System SR9000MK4U Product Guide...
Bottom left: RUSB2 – Top right: RUSB1 – Bottom right: RUSB0 Video port Standard VGA compatible, 15-pin connector Serial port 9-pin RS-232 connector Identification Button Toggles chassis ID LED on/off. Figure 7. Chassis Rear View ® Intel Server System SR9000MK4U Product Guide...
SPEED Yellow 1000 (left LED) Green None Fast Ether (Management ACT/LNK Green Link LAN, KVM LAN), ports (right LED) Green Blink Active Ether0 and Ether1 None No link SPEED Green (left LED) None ® Intel Server System SR9000MK4U Product Guide...
100-127 V 12 A Not supported Not supported Restriction of loading is needed. Two power supplies must be installed top operate the server system. Note: This value is applied to one power supply. ® Intel Server System SR9000MK4U Product Guide...
LED (green) is on. DC Output Good LED Indicates output power is good, when this LED (green) is on. Fault LED Indicates a fault with the power supply. Figure 9. Power Supply Indicators ® Intel Server System SR9000MK4U Product Guide...
AF001091 Cooling Fan LED Indicates fan is working normally when LED (green) is on Indicates fan has a fault when LED is off. Figure 10. Cooling Fan Indicator ® Intel Server System SR9000MK4U Product Guide...
Indicates PCI slot status is active. Attention LED and lens switch Indicates error, when this yellow LED is on. The lens switch is used for hot installs / removals. Figure 11. PCI Card Slot Indicator ® Intel Server System SR9000MK4U Product Guide...
Page 38
® Intel Server System SR9000MK4U Product Guide...
(installed in the memory boxes), one hard drive backplane and one ® front panel board. The block diagram of Intel Server System SR9000MK4U is as follows. The connection points between the main board and the front panel board are shown by the green circled numbers.
• Optimized design for 667 MHz FSB to achieve low memory access latency • Broadcast-based cache coherence control to minimize snoop transaction ® Intel ESB2 Enterprise South Bridge ® Intel 6700PXH 64-bit PCI Hub: • PCI bridging functions between the PCI Express interface and the PCI Bus •...
Page 42
Power LED LED to indicate an active PCI slot status P28-P33 PCI-X / PCI-Express* slot Attention LED LED to indicate an error other PCI card slot condition. See “PCI Card Slot” on page ® Intel Server System SR9000MK4U Product Guide...
Configuration Maximum Number of Processors Number PCI-Express* Input AC/DC Configuration Graphics Card ® ® Voltage Mounted Redundancy Restriction Intel Intel (75 W) AC/DC ® ® Itanium Itanium 533 MTS 667 MTS 100-127 200-240 Restricted, see note below Restricted, see note below Note: When one or two 75-watt PCI-Express* graphics cards are installed, the system will supply power for that slot during the power-on sequence or hot-add process.
Socket 1 Socket 2 Socket 3 Installed Not Installed Not Installed Not Installed Installed Installed Not Installed Not Installed Installed Not Installed Installed Not Installed Installed Installed Installed Not Installed Installed Installed Installed Installed ® Intel Server System SR9000MK4U Product Guide...
DIMMs. For a four-DIMM configuration, the DIMMs should be installed into locations JD0A1, JD0B1, JD2B1 and JD2A1. JD0A0 JD0A1 JD0B0 JD0B1 JD2B1 JD2B0 JD2A1 JD2A0 AF001101 Figure 16. DIMM Locations (Top View of Memory Box) ® Intel Server System SR9000MK4U Product Guide...
NDC linked to the MC with DIMMs installed can access all of the system memory with the shortest access time. Therefore, in some specialized situations, 3- A has a performance advantage to 2-A, such as in a two-socket installation. ® Intel Server System SR9000MK4U Product Guide...
Page 49
Memory mirroring is applicable to 3-A, but not to 2-A nor 1-B. Single Mode 1MMR/4DIMM Upgrade Path Upgrade Path 2MMR/8DIMM Single Mode Upgrade Path 2MMR/8DIMM Mirror Mode Double Mode Upgrade Path 4MMR/16DIMM Mirror Mode Double Mode AF001102 ® Intel Server System SR9000MK4U Product Guide...
SFF-8484 (SAS internal x4 connector) SAS1. See note below SFF-8484 (SAS internal x4 connector) 40-pin IDE connector Panel connector PNLPW Panel power Note: Available when additional SAS PCI card is inserted into PCI slot. ® Intel Server System SR9000MK4U Product Guide...
“Front Panel” on page Identification Switch, Identification LED “Front Panel” on page Power Fault LED “Front Panel” on page Cooling Fault LED “Front Panel” on page General Fault LED “Front Panel” on page ® Intel Server System SR9000MK4U Product Guide...
Table 17. Front Panel Board Connectors Board Location Connector Description USB4/5 USB Type A port x2 ® Intel Server System SR9000MK4U Product Guide...
Page 54
® Intel Server System SR9000MK4U Product Guide...
Installing and Removing Components To complete many of the installation or removal procedures in this chapter, you will need to first install or remove other components. For example, to remove the PCI card divider, you first need to remove the chassis cover, the power supplies, the power supply box, the CPU1/CPU2 MVR cable, the KVM card, and all add-in cards.
1. Insert your finger(s) into the hole at the left side of the front bezel. See letter “A” in the figure below. 2. Pull the bezel firmly. AF001104 Figure 21. Removing the Front Bezel ® Intel Server System SR9000MK4U Product Guide...
1. Set the left or right side of the bezel into place at the front of the system. 2. Set the opposite side of the bezel into place. 3. Push firmly until the bezel snaps into place. AF001105 Figure 22. Installing the Front Bezel ® Intel Server System SR9000MK4U Product Guide...
1. Pull up on the two levers on the top cover. See letter “A” in the following figure. 2. Lift the cover from the system. See letter “B” in the figure. AF001106 Figure 23. Removing the Top Cover ® Intel Server System SR9000MK4U Product Guide...
Handle the hard drive carefully. Inappropriate handling may result in hard drive failure. • Always create backup copies of important data on the hard disk. If the hard drive fails, all data stored on it will be lost. ® Intel Server System SR9000MK4U Product Guide...
5. Set the hard drive into the hard drive carrier, with the connections extending from the rear of the carrier. 6. Install the four screws that you removed in step 4, two on each side of the carrier. See letter “A” in the figure below. ® Intel Server System SR9000MK4U Product Guide...
8. Slide the hard drive carrier into the bay along the guide rail. See the figure below. 9. When the lower part of the lever touches the bay, push the lever closed while pushing the carrier into the system. AF001112 Figure 27. Installing a Hard Drive ® Intel Server System SR9000MK4U Product Guide...
2. Pull forward on the lever to open it. See letter “B”. 3. Continue pulling on the lever to slide the carrier from the system. AF001108 Figure 28. Pulling Down on the Hard Drive Carrier Lever ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — If you have completed working with the drive carrier, slide it back into the chassis opening. ® Intel Server System SR9000MK4U Product Guide...
You will need to remove the memory box to perform the following operations: • To replace a memory box • To install or remove DIMMs • To install or remove the mounting plate ® Intel Server System SR9000MK4U Product Guide...
Save the filler panel for future use. 4. If necessary, install DIMMs into the memory box. For instructions, see “Installing DIMMs” on page 5. Pull out on the metal front edge of the memory box. ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps to complete another procedure, return to those steps. — If you have finished with all steps and procedures, install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
— If a memory box will not be re-installed, slide a memory box filler panel into the open memory box slot until it clicks into place. 6. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
The following diagram shows the LEDs and components on the front of the memory box. AF001123 Mirror LED (green) Hot-swap button Power LED (green) Eject lever Attention LED (orange) Figure 35. Memory Box Front View ® Intel Server System SR9000MK4U Product Guide...
Page 69
9. If the power and memory LED do not return to solid on, power off the system to remove the memory box and repeat the installation. 10. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
AF001124 Figure 36. Four-DIMM Installation Pattern AF001125 Figure 37. Eight-DIMM Installation Pattern Note: The system will not boot if a memory box is installed with no DIMMs in it. ® Intel Server System SR9000MK4U Product Guide...
5. Make sure the DIMMs are inserted correctly and the clips are fully closed. 6. Install the memory box. For instructions, see “Installing a Memory Box” on page 43, beginning with step 6. ® Intel Server System SR9000MK4U Product Guide...
4. Install the memory box. For instructions, see “Installing a Memory Box” on page 43, beginning with step 6. Note: The system will not boot if a memory box is installed with no DIMMs in it. ® Intel Server System SR9000MK4U Product Guide...
3. Push the lever on the side of the optical drive or the filler panel to remove it from the system. Keep the filler panel for future use. AF001129 Figure 39. Removing the Optical Drive Filler Panel ® Intel Server System SR9000MK4U Product Guide...
6. Slide the optical drive assembly into the system until it clicks into place. See letter “A” in the figure below. AF001130 Figure 41. Installing of Optical Drive 7. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
2. Locate the optical drive location at the left side of the system. See the following figure. Figure 42. Locating the Optical Drive Installation Position 3. Push the lever on the optical drive to remove it from the system. AF001129 Figure 43. Removing Optical Drive from Server ® Intel Server System SR9000MK4U Product Guide...
Caution: Insert a blank/filler into any unused slot. Uncovered slots may reduce the cooling effect of the system. 6. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
1. Remove the top cover. For instructions, see “Removing the Top Cover” on page 2. Locate the fan area of the system. See the following figure. AF001133 Figure 45. Locating the Fans ® Intel Server System SR9000MK4U Product Guide...
4. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
Figure 47. Locating the Fans 3. Insert your thumb and a finger into the rounded and square holes at the top of the fan. 4. Lift the fan from the system. AF001135 Figure 48. Removing a Fan ® Intel Server System SR9000MK4U Product Guide...
3. Remove the fan. See “Removing a Fan” on page 4. Install the new fan. See “Installing a Fan” on page 5. Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
“Removing the Top Cover” on page 2. Locate the PCI slot area. See the following figure. 3. Lift the PCI caution plate. See letter “A” in the figure below. AF001138 Figure 50. Opening the PCI Caution Plate ® Intel Server System SR9000MK4U Product Guide...
AF001139 Figure 51. Unlocking a PCI Card Lock 5. Remove the PCI slot cover. See the figure below. Keep the slot cover for future use. AF001140 Figure 52. Removing a PCI Slot Cover ® Intel Server System SR9000MK4U Product Guide...
PCI tail lock. See Figure 53. Note: Full-length cards can be installed only into PCI slot 6. AF001136 Figure 53. PCI Tail Lock TP001141 Figure 54. Installing a PCI Card ® Intel Server System SR9000MK4U Product Guide...
10. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
1. Remove the top cover. For instructions, see “Removing the Top Cover” on page 2. Raise the PCI caution plate. See letter “A” in the figure below. AF001138 Figure 57. Opening a PCI Caution Plate ® Intel Server System SR9000MK4U Product Guide...
— For a full-length card: Pull back on the PCI tail lock to release the PCI card. See the figure below. While holding the PCI tail lock back, pull out the PCI card. AF001143 Figure 59. Releasing the PCI Card from the Tail Lock ® Intel Server System SR9000MK4U Product Guide...
Figure 60. Installing a PCI Slot Cover 6. Pull the PCI card lock until it locks into place. See the figure below. AF001142 Figure 61. Locking a PCI Card or Slot Cover into Place ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — If you are done working inside your server system, install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
7. Confirm that the power LED state changes from off to blinking to green. When the slot cover is inserted instead of PCI card, skip this operation. 8. Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
— Loosen the captive screw on the power supply filler. See letter “A” in the figure below. — Lift the power supply filler from the system. See letter “B” in the figure. Save the filler for future use. ® Intel Server System SR9000MK4U Product Guide...
4. Use the handle on the power supply to lower it into the system. See letter “B” in the figure. Caution: Do not lift the power supply by the levers. Lift the power supply only by the handle. AF001152 Figure 65. Installing a Power Supply ® Intel Server System SR9000MK4U Product Guide...
Care must be taken when you replace the power supply module; the cover or handle is hot when the system is powered on. • Before removing the power supply, pull up two levers to release the connector between power supply and main board. ® Intel Server System SR9000MK4U Product Guide...
3. Use the handle to lift the power supply from the system. See the figure below. Caution: Do not use the levers to lift or move the power supply. Only use the handle to lift the power supply. AF001155 Figure 68. Removing the Power Supply ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — If you are done working inside your server system, install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
Indicates input power is good, when this green LED is on. DC Output Good LED Indicates output power is good, when this green LED is on. Fault LED Indicates the power supply has a fault. Figure 70. Power Supply LED Indicators ® Intel Server System SR9000MK4U Product Guide...
See letter “A” in the figure below. 3. Pull out the front control panel / optical drive assembly. See letter “B” in the figure. AF001211 Figure 71. Removing the Front Control Panel and Optical Drive Assembly ® Intel Server System SR9000MK4U Product Guide...
3. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Power Supply Box” on page 80 to replace your power supply box. ® Intel Server System SR9000MK4U Product Guide...
4. Remove the cables from the clips at the top of the power supply box. See letters “C” and “D” in the figure. AF001432 Figure 74. Disconnecting the IDE and SATA Cables ® Intel Server System SR9000MK4U Product Guide...
See the figure below. AF001213 Figure 75. Loosening the Exterior Captive Screws 6. Loosen the two captive screws inside the system. See the figure below. AF001214 Figure 76. Loosening the Interior Captive Screws ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — If you are replacing your power supply box, continue with “Installing the Power Supply Box” on page ® Intel Server System SR9000MK4U Product Guide...
Figure 78. Inserting the Rear of Power Supply Box 2. Press down on the front of the power supply box to set it into place. AF001236 Figure 79. Setting the Front of the Power Supply Box into Place ® Intel Server System SR9000MK4U Product Guide...
AF001237 Figure 81. Tightening the External Power Supply Box Screws 5. Connect the CPU1 / CPU2 MVR cable from the main board. See the figure below to locate the MVR cable connection. ® Intel Server System SR9000MK4U Product Guide...
See letter “B” in the figure. 8. Insert the cables into the clips at the top of the power supply box. See letters “C” and “D” in the figure. AF001432 Figure 83. Connecting the IDE and SATA Cables ® Intel Server System SR9000MK4U Product Guide...
After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Power Supply Support” on page 85 to replace your power supply support. ® Intel Server System SR9000MK4U Product Guide...
Figure 84. Loosening the Power Supply Support Captive Screws 2. Lift the power supply support to remove it from the system. See the figure below. AF001240 Figure 85. Lifting the Power Supply Support from System ® Intel Server System SR9000MK4U Product Guide...
1. Set the power supply support into place in the system, lining up the guide pins in the chassis with the corresponding guide holes in the power supply support. See the figure below. AF001246 Figure 86. Setting the Power Supply Support into Place ® Intel Server System SR9000MK4U Product Guide...
✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — Reinstall the hard drive backplane cover. For instructions, see “Installing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
Figure 89. Installing the Hard Drive Backplane Cover 2. Push down on the backplane cover until it snaps into place. 3. Verify that two levers on top are latched, as shown by letter “A” below. ® Intel Server System SR9000MK4U Product Guide...
The power supply filler panel, if one is installed. For instructions, see “Installing a Power Supply” on page 68. Follow step 2 only. • The power supply box. For instructions, see “Removing the Power Supply Box” on page ® Intel Server System SR9000MK4U Product Guide...
Remove these components, in order, before beginning the steps below. 1. Line up the KVM card with the socket on the server board. Press the card firmly into place. Use caution so you do not bend or twist the KVM card. ® Intel Server System SR9000MK4U Product Guide...
“Removing the Power Supply Box” on page • The KVM card, if it is installed. For instructions, see “Removing the KVM Card” on page • All installed PCI cards. For instructions, see “Removing a PCI Card” on page ® Intel Server System SR9000MK4U Product Guide...
3. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the PCI card divider. For instructions, see “Installing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
1. Insert the two guides of the PCI divider into two guide holes near the bottom of the system. 2. Verify that the guides align with the guide holes in the chassis. Press down on the divider until it snaps into place. AF001232 Figure 93. Installing the PCI Divider ® Intel Server System SR9000MK4U Product Guide...
✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Air Flow Guide” on page 97 to replace your air flow guide. ® Intel Server System SR9000MK4U Product Guide...
2. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the air flow guide. For instructions, see “Installing the Air Flow Guide” on page ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — If you are ready to re-assemble your server system, install the following items, in order: ✧ The PCI card divider. For instructions, see “Installing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
“Removing the KVM Card” on page • All installed PCI cards. For instructions, see “Removing a PCI Card” on page • The PCI card divider. For instructions, see “Removing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
Fan Box” on page 101 to replace your fan box. 1. Loosen one screw on each side of the system, as shown by letter “A” in the figure below. AF001221 Figure 97. Loosening the Exterior Screws ® Intel Server System SR9000MK4U Product Guide...
2. Loosen the two captive screws on the interior of the system, as shown by the figure below. AF001222 Figure 98. Loosening the Interior Screws 3. Lift the fan box from the system, as shown below. AF001223 Figure 99. Lifting the Fan Box from the System ® Intel Server System SR9000MK4U Product Guide...
Figure 101. Tightening the Internal Fan Box Screws 3. Tighten the two external screws, one at each side of the system, as shown by the figure below. AF001230 Figure 102. Tighten the External Fan Box Screws ® Intel Server System SR9000MK4U Product Guide...
“Removing a Hard Drive” on page 40. Follow steps 1 through 3 only. • The front control panel and optical drive assembly. For instructions, see “Removing the Front Control Panel and Optical Drive Assembly” on page ® Intel Server System SR9000MK4U Product Guide...
Page 126
After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Hard Drive Backplane” on page 107 to replace your hard drive backplane. ® Intel Server System SR9000MK4U Product Guide...
1. Disconnect all cables from the hard drive backplane. 2. Remove the four screws from the hard drive backplane. See the following figure. AF001225 Table 18. Loosening the Hard Drive Backplane Screws ® Intel Server System SR9000MK4U Product Guide...
— If you are following these steps as part of another procedure, return to that procedure. — Reinstall the hard drive backplane or install a replacement hard drive backplane. For instructions, see “Installing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
“B” in the figure. 2. Press down on the backplane to engage the 12 chassis hooks with the backplane. See letter “C” in the figure. AF001227 Figure 104. Installing the Hard Drive Backplane ® Intel Server System SR9000MK4U Product Guide...
✧ The KVM card, if it is installed. For instructions, see “Installing the KVM Card” on page ✧ All installed PCI cards. For instructions, see “Installing a PCI Card” on page ® Intel Server System SR9000MK4U Product Guide...
Page 131
38. Follow steps 7 through 9 only, unless you also need to install hard drives into the carriers. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ✧ The front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
The following figure shows the components of the processor assembly. Refer to this figure as needed during the installation process to identify the components discussed in this section. AF001249 Processor Spring shroud Heat sink Bolster plate Spring clip Figure 106. Processor Assembly Components ® Intel Server System SR9000MK4U Product Guide...
After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Processor” on page 113 to replace your processor. ® Intel Server System SR9000MK4U Product Guide...
3. Use a Torx-15 screwdriver to loosen the four screws on the corners of the MVR. See letter “B” in the figure. AF001252 Figure 108. Loosening the MVR Screws 4. Lift the MVR straight up from the system to remove it. ® Intel Server System SR9000MK4U Product Guide...
• The power supply box. For instructions, see “Removing the Power Supply Box” on page • Remove the hard drive backplane cover. For instructions, see “Removing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
Do not touch the processor pins with either your hands or with the pin shroud. • The pin shroud is fragile. Use caution when installing it. Excessive flex will break the pin shroud. ® Intel Server System SR9000MK4U Product Guide...
5. Set the spring clip into place on the processor as shown below. The rounded edge of the spring clip should be positioned below the pin shroud. AF001264 Figure 111. Installing the Spring Clip ® Intel Server System SR9000MK4U Product Guide...
8. Use a Tork-15 screwdriver to tighten the four screws on the spring clip to secure the processor to the heat sink. Use a fastening torque of 0.45[N.m] (4.61[kgf.cm]. See the figure below. AF001259 Figure 113. Securing the Processor to the Heat Sink ® Intel Server System SR9000MK4U Product Guide...
Figure 114. Installing the Bolster Plate onto the Processor 10. Make sure the processor lock on the main board is in the unlocked position. See the figure below. AF001267 Figure 115. Making Sure the Processor Socket is Unlocked ® Intel Server System SR9000MK4U Product Guide...
13. Use a Torx-15 screwdriver to tighten the four screws on the corners of the heat sink. Use a torque level of 0.68[N.m] (6.9[kghf.cm]). See letter “B” in the figure. AF001269 Figure 117. Attaching the Processor and Heat Sink to the Main Board ® Intel Server System SR9000MK4U Product Guide...
Figure 118. Removing the Protective Cover from the LGA Terminal 15. Align the LGA terminal of the MVR with the LGA terminal pad of the processor assembly. AF001272 Figure 119. Setting the MVR into Place on the Processor Assembly ® Intel Server System SR9000MK4U Product Guide...
Figure 120. Attaching the MVR to the Processor Assembly 18. Press the MVR handles into place on each side of the MVR. See the figure below. AF001274 Figure 121. Installing the Handles onto the MVR ® Intel Server System SR9000MK4U Product Guide...
Page 143
✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
4. Verify that the processor lock is in the unlocked position. See letter “C”. 5. Lift the processor and heat sink assembly straight up to remove it from the server. AF001255 Figure 123. Loosening the Heat Sink Screws ® Intel Server System SR9000MK4U Product Guide...
Figure 124. Removing the Bolster Plate from the Processor 7. Use a Torx-15 screwdriver to loosen four spring clip screws. See letter “A” in the following figure. AF001259 Figure 125. Removing the Processor from the Heatsink ® Intel Server System SR9000MK4U Product Guide...
• The pin shroud is fragile. Use caution when removing it. Excessive flex will break the pin shroud. 11. Remove the pin shroud. AF001273 Figure 127. Removing the Pin Shroud from the Processor ® Intel Server System SR9000MK4U Product Guide...
3. Lift the mounting plate from the system. AF001242 Figure 128. Lifting the Mounting Plate from the System 4. Install a replacement mounting plate. For instructions, see “Installing the Mounting Plate” on page 127. ® Intel Server System SR9000MK4U Product Guide...
“Installing the Fan Box” on page 101. — All installed fans. For instructions, see “Installing a Fan” on page — The air flow guide. For instructions, see “Installing the Air Flow Guide” on page ® Intel Server System SR9000MK4U Product Guide...
Page 150
38. Follow steps 7 through 9 only, unless you also need to install hard drives into the carriers. — The top cover. For instructions, see “Installing the Top Cover” on page — The front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
Figure 130. Attaching the Chassis Handles Removing Chassis Handles 1. Loosen two screws that hold each handle assembly in place. 2. Lift the handle assembly from the chassis. 3. Repeat steps 1 - 2 for each handle. ® Intel Server System SR9000MK4U Product Guide...
Page 152
® Intel Server System SR9000MK4U Product Guide...
Configuration Software and Utilities The Extensible Firmware Interface (EFI) Boot Manager The EFI boot manager enables the user to control the booting environment of server. After power is on, the boot manager activates the system with various ways according to the boot option settings.
2. Press the <Enter> key. 3. Type the name of the EFI application to add 4. Press the <Enter> key. 5. Select [Save to NVRAM]. 6. Select [Exit] to return to the Boot Manager. ® Intel Server System SR9000MK4U Product Guide...
Page 155
3. Press the <b> key to start this option at the next time. Press the <r> key to reset. 4. Select [Save to NVRAM]. 5. Select [Exit] to return to the Boot Manager. ® Intel Server System SR9000MK4U Product Guide...
The details of EFI shell utility is provided by typing “help” and press the <Enter> key during EFI shell operation. In addition to basic shell commands in EFI shell, the user can create original commands and EFI applications in EFI environment. ® Intel Server System SR9000MK4U Product Guide...
Exits the EFI shell. Repeats a series of commands according to the condition. goto label Creates batch file that jumps to another label. guid [-b] Displays all GUIDs under the EFI environment. ® Intel Server System SR9000MK4U Product Guide...
Page 158
[hh:mm[:ss]] Displays or sets the time of the system. type [-a|-u] [-b] file [file...] Displays the contents of a file. Displays version information. vol [fs] [Volume Label] Displays volume information of a file. ® Intel Server System SR9000MK4U Product Guide...
MPT Firmware Revision 0.07.07.00-IT SAS Address 500605B0:00016CA0 Status Enabled Boot Support [Enabled BIOS & OS] SAS Topology Advanced Adapter Properties Esc = Exit Menu F1/Shift+1 = Help Enter = Select Item -/+ = Change Item ® Intel Server System SR9000MK4U Product Guide...
Page 160
5. Select the hard drive and press the <D> key. LSI Logic MPT Setup Utility 2.00.06.00 SAS Topology -- SAS1068 Device Identifier Device SAS1068(09:01:00) Info Controller Direct Attach Devices Expander FUJITSU MAX3036RC 2101 Esc=Exit F1=Help M=More Keys D=Device Properties ® Intel Server System SR9000MK4U Product Guide...
Page 161
Format may take hours to complete and cannot be stopped. Press the 'F' key to begin format or any other key to exit. Elapsed Time: 00:00:00 Percent Complete 100% /----------------------------------------\ \----------------------------------------/ Esc=Exit F1=Help M=More Keys ® Intel Server System SR9000MK4U Product Guide...
3. Hold down the reset button until the system LED begins to flash. 4. Power on the system. Upgrading the Firmware The FWUPDATE utility updates the SAL/BMC and writes sensor data records to the ® Intel Server System SR9000MK4U. A FWUPDATE is performed as an EFI shell command. ® Intel...
ROM#0 Copied to internal flash by BMC Integrated ROM file (The file 512KB reset sequence. that integrates the update ROM data.) BMC external SAL Spool flash AF001197 Figure 131. Firmware Update Block Diagram ® Intel Server System SR9000MK4U Product Guide...
Use ROM image data IA64_640.ROM in fs0 root directory. fwupdate fs0:\work\IA64_640.ROM; Use ROM image data IA64_640.ROM in fs0:work directory. fwupdate fs0:IA64_640.ROM; (not recommend) Command works if fs0 is the current drive Figure 132. FWUPDATE File Path Example ® Intel Server System SR9000MK4U Product Guide...
Updates only SAL in FWH and SAL Spool. /b or /B Updates only BMC in external flash. /n or /N Does not take over NVM area. (Invalid when /B or /S is specified.) ® Intel Server System SR9000MK4U Product Guide...
Before modifying any settings, be sure that the current values are recorded. When the restore of default values are required after CMOS clear, for example, the user must execute the setup again. By referring to the stored original settings, the restore operation may become easier. ® Intel Server System SR9000MK4U Product Guide...
Stores the changed values in CMOS, and exits setup. Clicking on the Exit menu item causes the system to prompt the user for a Yes or No response. Yes: Saves the changes and reboots the system. No: Aborts the action. ® Intel Server System SR9000MK4U Product Guide...
AC power recovery even if on is selected as the Power On option. Use the power button to power on the system, and then press and release the power button to shut down the server without forcing it into the power off state. ® Intel Server System SR9000MK4U Product Guide...
Enables / disables memory mirroring. Enable Failed Memory [Enable] Enable: Deconfigures the failure-detected memory and Deconfiguration boots. Disable: Cancels boot and turns off the power. Disable NUMA [Enable] Enables / disables NUMA memory configuration. Disable ® Intel Server System SR9000MK4U Product Guide...
Table 27 describes the menu items available on the Devices screen. Default values appear in brackets. Table 27. Devices Screen Primary Menu Item Sub Menu Item Options Description Onboard VGA [Enable] Enables / disables on-board VGA. Disable ® Intel Server System SR9000MK4U Product Guide...
EFI console input/output to COM1. Does not provide SPCR or HCDP to OS. When the valid VGA is not mounted, “Enable” is set. COM1 Speed 9600 bps Uses the communication speed specified when console redirection is valid. [19200bps] ® Intel Server System SR9000MK4U Product Guide...
1. Open “System Setup Menu” on the screen. 2. Choose “Server Management”: System Setup Menu Main Processor Memory Devices Server Management Security Save changes and Exit Discard changes and Exit Restore Defaults Exit ® Intel Server System SR9000MK4U Product Guide...
Page 174
EFI Utility User’s Guide. 8. Bundled management software will use User #10. Do not use this user number if you plan to use the management software that is included with your server system. ® Intel Server System SR9000MK4U Product Guide...
Troubleshooting Initial Troubleshooting Steps ® The Intel Server System SR9000MK4U implements indicators to display the system status. These are useful as a first step in identifying a problem. Begin troubleshooting by using the table below to view symptoms and solutions. If you do not find the answer you need in the table, continue with the information that follows the table.
Page 176
Disconnect and reconnect the USB cable and retry. Replace the keyboard. Mouse Mouse does not work Check that the mouse USB cable is normally. properly connected. Disconnect and reconnect the USB cable and retry. Replace the mouse. ® Intel Server System SR9000MK4U Product Guide...
Page 177
I/O card is not properly Check that the I/O card is installed into recognized. Attention LED the slot properly. (yellow) blinks. Check that the variety of I/O card corresponds to the installed slot. ® Intel Server System SR9000MK4U Product Guide...
Power Off Initialization EFI Shell Working OS Working System Hang State transition within normal operation State transition due to a failure AF001275 Figure 134. State Transition Diagram ® Intel Server System SR9000MK4U Product Guide...
Page 179
If you reproduced the problem, read the POST code. For instructions, see “How to Read the POST Codes” on page 159. If the system seems to have moved to the system hang status during the procedure, see “System Hang Status” on page 159. ® Intel Server System SR9000MK4U Product Guide...
Page 180
If you reproduced the problem, read the POST code. For instructions, see “How to Read the POST Codes” on page 159. If the system seems to have moved to a system hang status, follow the steps under System Hang Status, below. ® Intel Server System SR9000MK4U Product Guide...
How to Read the POST Codes The POST code decimal number is located inside the chassis at the right side. See the figure below. AF001270 Figure 135. Location of POST Code LED ® Intel Server System SR9000MK4U Product Guide...
9. Click Save. 10. Select “Security” in the tree display section. 11. Select “Save Log File As” from the Operation menu on the menu bar. 12. The “Save Security Log As” dialog box opens. ® Intel Server System SR9000MK4U Product Guide...
Page 183
27. From the command prompt, execute. dir \<WINDOWS>\system32\drivers > <X>:\drivers.txt 28. Type “exit” to close the command prompt. 29. Use Explorer* to confirm that the following files have been created on the external storage: system.evt system.csv security.evt ® Intel Server System SR9000MK4U Product Guide...
30. Use Notepad to confirm the following files contain some texts: system32.txt drivers.txt 31. Stop the external storage and remove the device from the system. Taking Corrective Action “POST Codes” on page 171 for suggested corrective actions. ® Intel Server System SR9000MK4U Product Guide...
Appendix A: Console Setup On-board VGA ® The Intel Server System SR9000MK4U server can output the SAL and EFI displays to on-board VGA. This subsection describes how to enable/disable the on-board VGA. 1. Select System Setup from the Boot Maintenance Menu of the EFI Boot Manager.
Page 186
Examine and set VGA parameters. Onboard VGA [Enable] Exit Use Enter to change value. 5. Select Exit twice and return to the System Setup Menu. 6. Select Save changes and Exit to end the System Setup. ® Intel Server System SR9000MK4U Product Guide...
Serial Console ® The Intel Server System SR9000MK4U server supports headless function that redirects the VGA output and keyboard input of SAL and EFI to the COM1 port input/output. This subsection describes how to enable/disable the headless function and how to set baud rate.
Page 188
6. Select COM1 Speed and set it to 9600 bps or 19200 bps. Set the baud rate that is set to the terminal connected to COM1 port. 7. Select Exit three times to return to the System Setup Menu. 8. Select Save changes and Exit to end the System Setup utility. ® Intel Server System SR9000MK4U Product Guide...
Appendix B: Cabling This appendix provides a a brief guideline about how to correctly attach and detach cables to prevent damage to the cable, or to the connector on the cable end or the server board. This appendix also provides photographs of the cable connections in the server system. Working with Ribbon Cables Make sure to detach (or attach) the flat cable assembly from the main board according to the following instructions.
Note: The figure above shows the system with the power supply box removed. AF001435 SATA 0 - 3 connector on hard drive SATA 4 - 7 connector on hard drive backplane backplane Figure 137. SATA Connections on Hard Drive Backplane ® Intel Server System SR9000MK4U Product Guide...
MVR connector for processors 1 and 2 MVR connector for processors 3 and 4 Figure 139. MVR Connectors Note: The figure above shows the system with the PCI card divider and the power supply box removed. ® Intel Server System SR9000MK4U Product Guide...
Page 192
AF001438 Control panel power connection on Control panel data connector hard drive backplane on server board Control panel data connector on Control panel power cable on hard drive backplane server board ® Intel Server System SR9000MK4U Product Guide...
Appendix C: POST Codes Table 31. POST Codes Generated by the BMC and Logged at the Seven Segment LED Operation to Code Descriptions Classification Recover reserved SRAM Check Started Progress SRAM Check Completed Progress Active side BMC F/W binary file checking Progress Spool side BMC F/W binary file checking Progress...
Page 194
Task booting process started Progress reserved reserved reserved reserved reserved reserved reserved Message handler started Progress PDK initialization process started Progress Task generation process started Progress BMC initialization completed Progress reserved reserved reserved reserved reserved reserved ® Intel Server System SR9000MK4U Product Guide...
Page 195
CPU2 I2C Access Error (PIROM) Error, error event logged to SEL CPU2 I2C Access Error (Temperature Monitor) Error, error event SEL List logged to SEL CPU3 Thermal Trip Error, error event logged to SEL ® Intel Server System SR9000MK4U Product Guide...
Page 196
PS0 Configuration Error (Insufficient Error, error event Resources) logged to SEL PS1 Configuration Error (Insufficient Error, error event Resources) logged to SEL PS1 Configuration Error (Different Type) Error, error event logged to SEL ® Intel Server System SR9000MK4U Product Guide...
Page 197
SEL CPU1 Configuration Error (Installation Rule) Error, error event logged to SEL CPU2 Configuration Error (Installation Rule) Error, error event logged to SEL Chassis Intrusion detected Error, error event logged to SEL reserved ® Intel Server System SR9000MK4U Product Guide...
Page 198
SEL MB Illegal Machine Check Interrupt Error, error event logged to SEL reserved HDDPL I2C Access Error (SEEPROM) Error, error event logged to SEL reserved reserved reserved reserved reserved reserved reserved reserved reserved ® Intel Server System SR9000MK4U Product Guide...
Segment LED Operation to Code Description Recover BSP selection Check previous SEL W Mutex service initialization NVSDA service initialization AP synchronization control Chipset low-level initialization PAL status check RTC initialization Super IO initialization ® Intel Server System SR9000MK4U Product Guide...
Page 200
Initialize interrupt vector table (IVT) Multiple host bus bridge initialization PCI initialization Transfer to virtual mode IA32BIOS execution Transfer to physical mode Initialize IDE controller PCI initialization after returning from IA32 BIOS RAS late initialization ® Intel Server System SR9000MK4U Product Guide...
Page 202
0xC0E3 Unexpected failure in the SAL machine Error check handler. 0xC0E4 Unexpected failure in the SAL machine Error check handler. 0xC0E6 Unexpected failure Error 0xA108 Unexpected failure in the machine Error check handler. ® Intel Server System SR9000MK4U Product Guide...
Appendix D: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.
Page 204
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR9000MK4U Product Guide...
Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR9000MK4U Product Guide...
Page 206
Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR9000MK4U Product Guide...
Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR9000MK4U Product Guide...
Page 208
Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. ® Intel Server System SR9000MK4U Product Guide...
Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación. ® Intel Server System SR9000MK4U Product Guide...
Page 210
También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. ® Intel Server System SR9000MK4U Product Guide...
Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato ® Intel Server System SR9000MK4U Product Guide...
Page 212
Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. ® Intel Server System SR9000MK4U Product Guide...
Page 213
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR9000MK4U Product Guide...
Page 214
® Intel Server System SR9000MK4U Product Guide...
Appendix E: Safety Information Warning Labels ® The Intel Server System SR9000MK4U contains several warning labels on the interior and exterior of the server system. These warning labels indicate components that present a potential danger. Do not remove these warning labels. The following diagrams show the labels and their locations.
AF001422 Figure 141. Caution: Server System is Heavy The warnings labels at the rear of the server chassis contains voltage information. AF001423 Figure 142. Caution: System Contains Areas of High Voltage ® Intel Server System SR9000MK4U Product Guide...
To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation. ® Intel Server System SR9000MK4U Product Guide...
Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR9000MK4U Product Guide...
A separate AC cord is required for each system power supply. ® • Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
Caution: To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the fan guard in place. ® Intel Server System SR9000MK4U Product Guide...
After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. ® Intel Server System SR9000MK4U Product Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR9000MK4U Product Guide...
Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
Telekommunikationskabel zum Modem abziehen. • Eine ordnungsgemäß geerdete Wandsteckdose muß vorhanden sein. • Ausreichender Freiraum für den Zugang zu den Netzkabeln, da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind. ® Intel Server System SR9000MK4U Product Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder ® Intel Server System SR9000MK4U Product Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR9000MK4U Product Guide...
• Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR9000MK4U Product Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR9000MK4U Product Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. ® Intel Server System SR9000MK4U Product Guide...
Mettez la pile au rebut en vous conformant aux réglementations locales. N’essayez pas de recharger une pile. N’essayez pas de démonter, de percer ou d’endommager la pile d’une quelconque façon. ® Intel Server System SR9000MK4U Product Guide...
Page 235
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. ® Intel Server System SR9000MK4U Product Guide...
Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. ® Intel Server System SR9000MK4U Product Guide...
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. ® Intel Server System SR9000MK4U Product Guide...
Deseche las baterías respetando la normativa local. No intente recargar la batería. No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería. ® Intel Server System SR9000MK4U Product Guide...
Page 241
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR9000MK4U Product Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out a server issue report form.For the fastest service, please submit your form via the Internet.
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR9000MK4U Product Guide...
Page 249
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR9000MK4U Product Guide...
Page 250
® Intel Server System SR9000MK4U Product Guide...
(or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information please contact your local Intel Representative.
Product EMC Compliance - Class A Compliance Note: Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits • FCC / ICES-003 - Emissions (USA/Canada) Verification •...
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR9000MK4U Product Guide...
RRL (Korea) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) UL listed.
Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.
Page 258
® Intel Server System SR9000MK4U Product Guide...
Need help?
Do you have a question about the SR9000MK4U - Server System - 0 MB RAM and is the answer not in the manual?
Questions and answers