Intel SR9000MK4U - Server System - 0 MB RAM Product Manual

Product guide
Hide thumbs Also See for SR9000MK4U - Server System - 0 MB RAM:
Table of Contents

Advertisement

Quick Links

®
Intel
Server System
SR9000MK4U Product Guide
Intel Order Number D71314-004

Advertisement

Table of Contents
loading

Summary of Contents for Intel SR9000MK4U - Server System - 0 MB RAM

  • Page 1 ® Intel Server System SR9000MK4U Product Guide Intel Order Number D71314-004...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor...
  • Page 4 Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. ® Intel Server System SR9000MK4U Product Guide...
  • Page 5 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR9000MK4U Product Guide...
  • Page 6 ® Intel Server System SR9000MK4U Product Guide...
  • Page 7: Preface

    Preface About this Manual ® Thank you for purchasing and using Intel server products. This manual is written for system technicians who are responsible for troubleshooting, ® upgrading, and managing the Intel Server System SR9000MK4U. This document provides an overview of the features of the server system utilities, and instructions on how to install, setup, and manage the system.
  • Page 8: Product Accessories

    Processor, memory DIMMs, hard drive, USB floppy drive, CD-ROM or DVD-ROM drive, RAID controller, operating system. For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SR9000MK4U/ compat.htm.
  • Page 9 Operating System Driver (for operating system drivers) For firmware and BIOS Firmware Updates updates, or for BIOS recovery For diagnostics test Diagnostics software See also the Resource CD that came with your server system. ® Intel Server System SR9000MK4U Product Guide...
  • Page 10: Powering The System On And Off

    When the system power is forced off, either the power button or the IPMI “Power On” command must be used to power the system back on. ® Intel Server System SR9000MK4U Product Guide...
  • Page 11: Table Of Contents

    Powering the System On and Off ..................x Powering On the System Power ..................x Powering Off the System Power ..................x ® Chapter 1: Intel Server System SR9000MK4U Chassis Overview ....... 1 Chassis Description ....................... 2 External Chassis Features .....................3 Chassis Front ........................
  • Page 12 Installing and Removing the Hard Drive Backplane Cover ..........87 Removing the Hard Drive Backplane Cover ............... 87 Installing the Hard Drive Backplane Cover ..............88 Installing and Removing the KVM Card ................89 ® Intel Server System SR9000MK4U Product Guide...
  • Page 13 Navigating Setup Utility Screens ................146 Primary Screens ......................146 Configuring Serial-Over LAN .....................151 Chapter 5: Troubleshooting .................. 153 Initial Troubleshooting Steps .....................153 Collecting System State Information ..................156 How to Read the POST Codes ..................159 ® Intel Server System SR9000MK4U Product Guide xiii...
  • Page 14 Handhabung von Geräten ..................204 Warnungen zu Netzspannung und Elektrizität ............204 Warnhinweise für den Systemzugang ............... 205 Warnhinweise für Racks ................... 206 Elektrostatische Entladungen (ESD) ................. 206 Andere Gefahren ....................... 207 Français ..........................208 ® Intel Server System SR9000MK4U Product Guide...
  • Page 15 Europe (CE Declaration of Conformity) ..............232 VCCI (Japan) ......................232 BSMI (Taiwan) ......................233 RRL (Korea) ......................233 CNCA (CCC China) ....................233 Regulated Specified Components ..................234 Restriction of Hazardous Substances (RoHS) Compliance ..........235 End of Life / Product Recycling ..................235 ® Intel Server System SR9000MK4U Product Guide...
  • Page 16 ® Intel Server System SR9000MK4U Product Guide...
  • Page 17 List of Figures ® Figure 1. Intel Server System SR9000MK4U Three Dimensional View........1 Figure 2. Chassis Front View ....................4 Figure 3. Front Panel Controls and Indicators................5 Figure 4. Optical Drive Bracket with Drive Installed ..............6 Figure 5. Hard Drive Carrier ...................... 6 Figure 6.
  • Page 18 Figure 86. Setting the Power Supply Support into Place ............85 Figure 87. Tightening the Power Supply Support Screws ............86 Figure 88. Removing the Hard Drive Backplane Cover ............87 Figure 89. Installing the Hard Drive Backplane Cover ............88 ® xviii Intel Server System SR9000MK4U Product Guide...
  • Page 19 Figure 133. FWUPDATE Execution Screen................144 Figure 134. State Transition Diagram ................... 156 Figure 135. Location of POST Code LED ................159 Figure 136. Connections Near Power Supply Box and PCI Card Divider ......168 ® Intel Server System SR9000MK4U Product Guide...
  • Page 20 Figure 141. Caution: Server System is Heavy ..............194 Figure 142. Caution: System Contains Areas of High Voltage ..........194 Figure 143. Warning: Voltage on Non Hot-swap Power Supply ........... 195 Figure 144. Warning: Voltage on Hot-swap Power Supply........... 195 ® Intel Server System SR9000MK4U Product Guide...
  • Page 21 Table 31. POST Codes Generated by the BMC and Logged at the Seven Segment LED ...171 Table 32. POST Codes Generated by SAL and Logged at the Seven Segment LED ..177 Table 33. Error POST Codes Generated by SAL ..............179 ® Intel Server System SR9000MK4U Product Guide...
  • Page 22 ® xxii Intel Server System SR9000MK4U Product Guide...
  • Page 23: Chapter 1: Intel ® Server System Sr9000Mk4U Chassis Overview

    Server System SR9000MK4U as shown in Figure 1 is a compact, high-density ® ® rack-mount server system with support for up to four Intel Itanium 2 processors and 256-GB DDR2 SDRAM memory. The system is based on the Hitachi CF-3e board set and the Hitachi CF-3e chipset.
  • Page 24: Chassis Description

    Remote diagnostics support across the LAN • Remote KVM across the LAN • Remote optical drive access across the LAN • ® ® Upgrades Field upgradeable to the next generation Intel Itanium processor family • Multi-generational chassis ® Intel Server System SR9000MK4U Product Guide...
  • Page 25: External Chassis Features

    — Memory box: Memory box serviceability LEDs • Chassis rear — Power supplies and AC inputs — PCI slots — IO ports — Identification switch • Chassis top — Power supply indicators — Cooling fan — PCI hot plug ® Intel Server System SR9000MK4U Product Guide...
  • Page 26: Chassis Front

    Front Panel, see “Front Panel” Memory box 1 Optical Drive Memory box 2 Hard Drives, HDD0 - HDD7 from left to right Memory box 3 Memory box 0 Figure 2. Chassis Front View ® Intel Server System SR9000MK4U Product Guide...
  • Page 27: Figure 3. Front Panel Controls And Indicators

    Orange blink: Non-critical fault other than power or cooling fault detected. – Off: No general fault detected. System diagnostic interrupt (SDINT) button: Asserts INIT to system. Figure 3. Front Panel Controls and Indicators ® Intel Server System SR9000MK4U Product Guide...
  • Page 28: Figure 4. Optical Drive Bracket With Drive Installed

    The system power must be turned off to remove or install this drive. AF001084 Figure 4. Optical Drive Bracket with Drive Installed ® Note: Intel validates specific DVD-ROM / CD-ROM drives. See the Intel Server System SR9000MK4U Tested Hardware and Operating System List” for a list of these drives available.
  • Page 29: Table 4. Sas Hard Drive Led Details

    Watch for the LED status to change. The red LED should be on for 0.5 seconds, then the green turns on and remains on. • Intel validates specific hard drive types in the Server System SR9000MK4U. See the ® Intel Server System SR9000MK4U Tested Hardware and Operating System List for a list of the drives supported.
  • Page 30: Figure 6. Memory Box Front View

    No error has been detected on the memory box or the memory box is powered off. No LED Hot-swap button. Press this button to initiate a hot-swap process. Figure 6. Memory Box Front View ® Intel Server System SR9000MK4U Product Guide...
  • Page 31: Chassis Rear

    Bottom left: RUSB2 – Top right: RUSB1 – Bottom right: RUSB0 Video port Standard VGA compatible, 15-pin connector Serial port 9-pin RS-232 connector Identification Button Toggles chassis ID LED on/off. Figure 7. Chassis Rear View ® Intel Server System SR9000MK4U Product Guide...
  • Page 32: Table 5. Nic Leds

    SPEED Yellow 1000 (left LED) Green None Fast Ether (Management ACT/LNK Green Link LAN, KVM LAN), ports (right LED) Green Blink Active Ether0 and Ether1 None No link SPEED Green (left LED) None ® Intel Server System SR9000MK4U Product Guide...
  • Page 33: Internal Layout

    AA. Memory Box 0 PCI Express, x 16, Slot 2 Memory Box 3 BB. DIMM Sockets PCI-X, Slot 3 DIMM Sockets PCI-Express, x8, Slot 4 DIMM Sockets Figure 8. Open System, Top View ® Intel Server System SR9000MK4U Product Guide...
  • Page 34: Internal Chassis Features

    100-127 V 12 A Not supported Not supported Restriction of loading is needed. Two power supplies must be installed top operate the server system. Note: This value is applied to one power supply. ® Intel Server System SR9000MK4U Product Guide...
  • Page 35: Figure 9. Power Supply Indicators

    LED (green) is on. DC Output Good LED Indicates output power is good, when this LED (green) is on. Fault LED Indicates a fault with the power supply. Figure 9. Power Supply Indicators ® Intel Server System SR9000MK4U Product Guide...
  • Page 36: Cooling Subsystem

    AF001091 Cooling Fan LED Indicates fan is working normally when LED (green) is on Indicates fan has a fault when LED is off. Figure 10. Cooling Fan Indicator ® Intel Server System SR9000MK4U Product Guide...
  • Page 37: Pci Card Slot

    Indicates PCI slot status is active. Attention LED and lens switch Indicates error, when this yellow LED is on. The lens switch is used for hot installs / removals. Figure 11. PCI Card Slot Indicator ® Intel Server System SR9000MK4U Product Guide...
  • Page 38 ® Intel Server System SR9000MK4U Product Guide...
  • Page 39: Chapter 2: Intel ® Server System Sr9000Mk4U Board Set Overview

    (installed in the memory boxes), one hard drive backplane and one ® front panel board. The block diagram of Intel Server System SR9000MK4U is as follows. The connection points between the main board and the front panel board are shown by the green circled numbers.
  • Page 40: Main Board

    IPMB MVR2/3 Processor Socket2 DEBUG VHDM2 PCI slot1 Battery PCI slot2 Processor Socket3 PCI slot3 PCI slot4 VHDM3 PCI slot5 NDC1 7SEG PANEL PCI slot6 PANEL PWR AF001095 Figure 13. Main Board Layout ® Intel Server System SR9000MK4U Product Guide...
  • Page 41: Table 7. Main Board Components

    • Optimized design for 667 MHz FSB to achieve low memory access latency • Broadcast-based cache coherence control to minimize snoop transaction ® Intel ESB2 Enterprise South Bridge ® Intel 6700PXH 64-bit PCI Hub: • PCI bridging functions between the PCI Express interface and the PCI Bus •...
  • Page 42 Power LED LED to indicate an active PCI slot status P28-P33 PCI-X / PCI-Express* slot Attention LED LED to indicate an error other PCI card slot condition. See “PCI Card Slot” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 43: Table 8. Main Board External I/O Connectors

    C7/C10 PCI slot 3/6 64-bit 133 MHz PCI-X* slots C11~C14 VHDM 0/1/2/3 C15~C20 FAN 0/1/2/3/4/5 C21/C22 PS 0/1 SFF-8484 (SAS internal x4 connector) 40-pin IDE connector PNLPW C27/C28 MVR0/1, MVR2/3 SATA IPMB DEBUG ® Intel Server System SR9000MK4U Product Guide...
  • Page 44: Configuration Restrictions

    Configuration Maximum Number of Processors Number PCI-Express* Input AC/DC Configuration Graphics Card ® ® Voltage Mounted Redundancy Restriction Intel Intel (75 W) AC/DC ® ® Itanium Itanium 533 MTS 667 MTS 100-127 200-240 Restricted, see note below Restricted, see note below Note: When one or two 75-watt PCI-Express* graphics cards are installed, the system will supply power for that slot during the power-on sequence or hot-add process.
  • Page 45: Processor Configurations

    Socket 1 Socket 2 Socket 3 Installed Not Installed Not Installed Not Installed Installed Installed Not Installed Not Installed Installed Not Installed Installed Not Installed Installed Installed Installed Not Installed Installed Installed Installed Installed ® Intel Server System SR9000MK4U Product Guide...
  • Page 46: Memory Box Card

    240-pin DDR2 DIMM socket (MC0 channel B) JD0A0 240-pin DDR2 DIMM socket (MC0 channel B) JD2B1 240-pin DDR2 DIMM socket (MC1 channel A) JD2B0 240-pin DDR2 DIMM socket (MC1 channel A) JD2A1 240-pin DDR2 DIMM socket (MC1 channel B) ® Intel Server System SR9000MK4U Product Guide...
  • Page 47: Dimm Configurations

    DIMMs. For a four-DIMM configuration, the DIMMs should be installed into locations JD0A1, JD0B1, JD2B1 and JD2A1. JD0A0 JD0A1 JD0B0 JD0B1 JD2B1 JD2B0 JD2A1 JD2A0 AF001101 Figure 16. DIMM Locations (Top View of Memory Box) ® Intel Server System SR9000MK4U Product Guide...
  • Page 48: Table 14. Memory Operational Modes

    NDC linked to the MC with DIMMs installed can access all of the system memory with the shortest access time. Therefore, in some specialized situations, 3- A has a performance advantage to 2-A, such as in a two-socket installation. ® Intel Server System SR9000MK4U Product Guide...
  • Page 49 Memory mirroring is applicable to 3-A, but not to 2-A nor 1-B. Single Mode 1MMR/4DIMM Upgrade Path Upgrade Path 2MMR/8DIMM Single Mode Upgrade Path 2MMR/8DIMM Mirror Mode Double Mode Upgrade Path 4MMR/16DIMM Mirror Mode Double Mode AF001102 ® Intel Server System SR9000MK4U Product Guide...
  • Page 50: Figure 17. Memory Upgrade Path

    Upgrade Path Upgrade Path 2MMR/16DIMM Single Mode Upgrade Path 2MMR/16DIMM Mirror Mode Double Mode Upgrade Path 4MMR/24DIMM Mirror Mode Double Mode Upgrade Path 4MMR/32DIMM Mirror Mode Double Mode AF001103 Figure 17. Memory Upgrade Path ® Intel Server System SR9000MK4U Product Guide...
  • Page 51: Hard Drive Backplane

    SFF-8484 (SAS internal x4 connector) SAS1. See note below SFF-8484 (SAS internal x4 connector) 40-pin IDE connector Panel connector PNLPW Panel power Note: Available when additional SAS PCI card is inserted into PCI slot. ® Intel Server System SR9000MK4U Product Guide...
  • Page 52: Hard Drive Population

    “Front Panel” on page Identification Switch, Identification LED “Front Panel” on page Power Fault LED “Front Panel” on page Cooling Fault LED “Front Panel” on page General Fault LED “Front Panel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 53: Table 17. Front Panel Board Connectors

    Table 17. Front Panel Board Connectors Board Location Connector Description USB4/5 USB Type A port x2 ® Intel Server System SR9000MK4U Product Guide...
  • Page 54 ® Intel Server System SR9000MK4U Product Guide...
  • Page 55: Chapter 3: Installing And Removing Components

    Installing and Removing Components To complete many of the installation or removal procedures in this chapter, you will need to first install or remove other components. For example, to remove the PCI card divider, you first need to remove the chassis cover, the power supplies, the power supply box, the CPU1/CPU2 MVR cable, the KVM card, and all add-in cards.
  • Page 56: Installing And Removing The Front Bezel

    1. Insert your finger(s) into the hole at the left side of the front bezel. See letter “A” in the figure below. 2. Pull the bezel firmly. AF001104 Figure 21. Removing the Front Bezel ® Intel Server System SR9000MK4U Product Guide...
  • Page 57: Installing The Front Bezel

    1. Set the left or right side of the bezel into place at the front of the system. 2. Set the opposite side of the bezel into place. 3. Push firmly until the bezel snaps into place. AF001105 Figure 22. Installing the Front Bezel ® Intel Server System SR9000MK4U Product Guide...
  • Page 58: Installing And Removing The Top Cover

    1. Pull up on the two levers on the top cover. See letter “A” in the following figure. 2. Lift the cover from the system. See letter “B” in the figure. AF001106 Figure 23. Removing the Top Cover ® Intel Server System SR9000MK4U Product Guide...
  • Page 59: Installing The Top Cover

    Handle the hard drive carefully. Inappropriate handling may result in hard drive failure. • Always create backup copies of important data on the hard disk. If the hard drive fails, all data stored on it will be lost. ® Intel Server System SR9000MK4U Product Guide...
  • Page 60: Installing A Hard Drive

    5. Set the hard drive into the hard drive carrier, with the connections extending from the rear of the carrier. 6. Install the four screws that you removed in step 4, two on each side of the carrier. See letter “A” in the figure below. ® Intel Server System SR9000MK4U Product Guide...
  • Page 61: Figure 26. Mounting A Hard Drive

    8. Slide the hard drive carrier into the bay along the guide rail. See the figure below. 9. When the lower part of the lever touches the bay, push the lever closed while pushing the carrier into the system. AF001112 Figure 27. Installing a Hard Drive ® Intel Server System SR9000MK4U Product Guide...
  • Page 62: Removing A Hard Drive

    2. Pull forward on the lever to open it. See letter “B”. 3. Continue pulling on the lever to slide the carrier from the system. AF001108 Figure 28. Pulling Down on the Hard Drive Carrier Lever ® Intel Server System SR9000MK4U Product Guide...
  • Page 63: Figure 29. Unmounting A Hard Drive

    — If you are following these steps as part of another procedure, return to that procedure. — If you have completed working with the drive carrier, slide it back into the chassis opening. ® Intel Server System SR9000MK4U Product Guide...
  • Page 64: Hot-Swapping A Hard Drive

    You will need to remove the memory box to perform the following operations: • To replace a memory box • To install or remove DIMMs • To install or remove the mounting plate ® Intel Server System SR9000MK4U Product Guide...
  • Page 65: Installing A Memory Box

    Save the filler panel for future use. 4. If necessary, install DIMMs into the memory box. For instructions, see “Installing DIMMs” on page 5. Pull out on the metal front edge of the memory box. ® Intel Server System SR9000MK4U Product Guide...
  • Page 66: Figure 32. Installing The Memory Box

    — If you are following these steps to complete another procedure, return to those steps. — If you have finished with all steps and procedures, install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 67: Removing A Memory Box

    — If a memory box will not be re-installed, slide a memory box filler panel into the open memory box slot until it clicks into place. 6. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 68: Hot-Swapping A Memory Box

    The following diagram shows the LEDs and components on the front of the memory box. AF001123 Mirror LED (green) Hot-swap button Power LED (green) Eject lever Attention LED (orange) Figure 35. Memory Box Front View ® Intel Server System SR9000MK4U Product Guide...
  • Page 69 9. If the power and memory LED do not return to solid on, power off the system to remove the memory box and repeat the installation. 10. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 70: Installing And Removing Dimms

    AF001124 Figure 36. Four-DIMM Installation Pattern AF001125 Figure 37. Eight-DIMM Installation Pattern Note: The system will not boot if a memory box is installed with no DIMMs in it. ® Intel Server System SR9000MK4U Product Guide...
  • Page 71: Installing Dimms

    5. Make sure the DIMMs are inserted correctly and the clips are fully closed. 6. Install the memory box. For instructions, see “Installing a Memory Box” on page 43, beginning with step 6. ® Intel Server System SR9000MK4U Product Guide...
  • Page 72: Removing Dimms

    4. Install the memory box. For instructions, see “Installing a Memory Box” on page 43, beginning with step 6. Note: The system will not boot if a memory box is installed with no DIMMs in it. ® Intel Server System SR9000MK4U Product Guide...
  • Page 73: Installing And Removing An Optical Drive

    3. Push the lever on the side of the optical drive or the filler panel to remove it from the system. Keep the filler panel for future use. AF001129 Figure 39. Removing the Optical Drive Filler Panel ® Intel Server System SR9000MK4U Product Guide...
  • Page 74: Figure 40. Attaching The Optical Drive To The Bracket

    6. Slide the optical drive assembly into the system until it clicks into place. See letter “A” in the figure below. AF001130 Figure 41. Installing of Optical Drive 7. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 75: Removing The Optical Drive

    2. Locate the optical drive location at the left side of the system. See the following figure. Figure 42. Locating the Optical Drive Installation Position 3. Push the lever on the optical drive to remove it from the system. AF001129 Figure 43. Removing Optical Drive from Server ® Intel Server System SR9000MK4U Product Guide...
  • Page 76: Figure 44. Removing The Optical Drive From The Bracket

    Caution: Insert a blank/filler into any unused slot. Uncovered slots may reduce the cooling effect of the system. 6. Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 77: Installing And Removing A Fan

    1. Remove the top cover. For instructions, see “Removing the Top Cover” on page 2. Locate the fan area of the system. See the following figure. AF001133 Figure 45. Locating the Fans ® Intel Server System SR9000MK4U Product Guide...
  • Page 78: Figure 46. Installing A Fan

    4. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 79: Removing A Fan

    Figure 47. Locating the Fans 3. Insert your thumb and a finger into the rounded and square holes at the top of the fan. 4. Lift the fan from the system. AF001135 Figure 48. Removing a Fan ® Intel Server System SR9000MK4U Product Guide...
  • Page 80: Hot-Swapping A Fan

    3. Remove the fan. See “Removing a Fan” on page 4. Install the new fan. See “Installing a Fan” on page 5. Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 81: Installing And Removing A Pci Card

    “Removing the Top Cover” on page 2. Locate the PCI slot area. See the following figure. 3. Lift the PCI caution plate. See letter “A” in the figure below. AF001138 Figure 50. Opening the PCI Caution Plate ® Intel Server System SR9000MK4U Product Guide...
  • Page 82: Figure 51. Unlocking A Pci Card Lock

    AF001139 Figure 51. Unlocking a PCI Card Lock 5. Remove the PCI slot cover. See the figure below. Keep the slot cover for future use. AF001140 Figure 52. Removing a PCI Slot Cover ® Intel Server System SR9000MK4U Product Guide...
  • Page 83: Figure 53. Pci Tail Lock

    PCI tail lock. See Figure 53. Note: Full-length cards can be installed only into PCI slot 6. AF001136 Figure 53. PCI Tail Lock TP001141 Figure 54. Installing a PCI Card ® Intel Server System SR9000MK4U Product Guide...
  • Page 84: Figure 55. Locking A Pci Card Into Place

    10. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 85: Removing A Pci Card

    1. Remove the top cover. For instructions, see “Removing the Top Cover” on page 2. Raise the PCI caution plate. See letter “A” in the figure below. AF001138 Figure 57. Opening a PCI Caution Plate ® Intel Server System SR9000MK4U Product Guide...
  • Page 86: Figure 58. Unlocking A Pci Card Lock

    — For a full-length card: Pull back on the PCI tail lock to release the PCI card. See the figure below. While holding the PCI tail lock back, pull out the PCI card. AF001143 Figure 59. Releasing the PCI Card from the Tail Lock ® Intel Server System SR9000MK4U Product Guide...
  • Page 87: Figure 60. Installing A Pci Slot Cover

    Figure 60. Installing a PCI Slot Cover 6. Pull the PCI card lock until it locks into place. See the figure below. AF001142 Figure 61. Locking a PCI Card or Slot Cover into Place ® Intel Server System SR9000MK4U Product Guide...
  • Page 88: Figure 62. Closing The Pci Caution Plate

    — If you are following these steps as part of another procedure, return to that procedure. — If you are done working inside your server system, install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 89: Hot-Plugging A Pci Card

    7. Confirm that the power LED state changes from off to blinking to green. When the slot cover is inserted instead of PCI card, skip this operation. 8. Install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 90: Installing And Removing A Power Supply

    — Loosen the captive screw on the power supply filler. See letter “A” in the figure below. — Lift the power supply filler from the system. See letter “B” in the figure. Save the filler for future use. ® Intel Server System SR9000MK4U Product Guide...
  • Page 91: Figure 64. Removing A Power Supply Filler

    4. Use the handle on the power supply to lower it into the system. See letter “B” in the figure. Caution: Do not lift the power supply by the levers. Lift the power supply only by the handle. AF001152 Figure 65. Installing a Power Supply ® Intel Server System SR9000MK4U Product Guide...
  • Page 92: Removing A Power Supply

    Care must be taken when you replace the power supply module; the cover or handle is hot when the system is powered on. • Before removing the power supply, pull up two levers to release the connector between power supply and main board. ® Intel Server System SR9000MK4U Product Guide...
  • Page 93: Figure 67. Opening The Power Supply Levers

    3. Use the handle to lift the power supply from the system. See the figure below. Caution: Do not use the levers to lift or move the power supply. Only use the handle to lift the power supply. AF001155 Figure 68. Removing the Power Supply ® Intel Server System SR9000MK4U Product Guide...
  • Page 94: Figure 69. Installing A Power Supply Filler

    — If you are following these steps as part of another procedure, return to that procedure. — If you are done working inside your server system, install the top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 95: Hot-Swapping A Power Supply

    Indicates input power is good, when this green LED is on. DC Output Good LED Indicates output power is good, when this green LED is on. Fault LED Indicates the power supply has a fault. Figure 70. Power Supply LED Indicators ® Intel Server System SR9000MK4U Product Guide...
  • Page 96: Installing And Removing The Front Control Panel And Optical Drive Assembly

    See letter “A” in the figure below. 3. Pull out the front control panel / optical drive assembly. See letter “B” in the figure. AF001211 Figure 71. Removing the Front Control Panel and Optical Drive Assembly ® Intel Server System SR9000MK4U Product Guide...
  • Page 97: Installing The Front Control Panel And Optical Drive Assembly

    3. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Install the front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 98: Installing And Removing The Power Supply Box

    After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Power Supply Box” on page 80 to replace your power supply box. ® Intel Server System SR9000MK4U Product Guide...
  • Page 99: Figure 73. Locating The Cpu1 / Cpu2 Mvr Connection

    4. Remove the cables from the clips at the top of the power supply box. See letters “C” and “D” in the figure. AF001432 Figure 74. Disconnecting the IDE and SATA Cables ® Intel Server System SR9000MK4U Product Guide...
  • Page 100: Figure 75. Loosening The Exterior Captive Screws

    See the figure below. AF001213 Figure 75. Loosening the Exterior Captive Screws 6. Loosen the two captive screws inside the system. See the figure below. AF001214 Figure 76. Loosening the Interior Captive Screws ® Intel Server System SR9000MK4U Product Guide...
  • Page 101: Figure 77. Lifting The Power Supply Box From System

    — If you are following these steps as part of another procedure, return to that procedure. — If you are replacing your power supply box, continue with “Installing the Power Supply Box” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 102: Installing The Power Supply Box

    Figure 78. Inserting the Rear of Power Supply Box 2. Press down on the front of the power supply box to set it into place. AF001236 Figure 79. Setting the Front of the Power Supply Box into Place ® Intel Server System SR9000MK4U Product Guide...
  • Page 103: Figure 80. Tightening The Internal Power Supply Box Screws

    AF001237 Figure 81. Tightening the External Power Supply Box Screws 5. Connect the CPU1 / CPU2 MVR cable from the main board. See the figure below to locate the MVR cable connection. ® Intel Server System SR9000MK4U Product Guide...
  • Page 104: Figure 82. Locating The Cpu1 / Cpu2 Mvr Connection

    See letter “B” in the figure. 8. Insert the cables into the clips at the top of the power supply box. See letters “C” and “D” in the figure. AF001432 Figure 83. Connecting the IDE and SATA Cables ® Intel Server System SR9000MK4U Product Guide...
  • Page 105: Installing And Removing The Power Supply Support

    After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Power Supply Support” on page 85 to replace your power supply support. ® Intel Server System SR9000MK4U Product Guide...
  • Page 106: Figure 84. Loosening The Power Supply Support Captive Screws

    Figure 84. Loosening the Power Supply Support Captive Screws 2. Lift the power supply support to remove it from the system. See the figure below. AF001240 Figure 85. Lifting the Power Supply Support from System ® Intel Server System SR9000MK4U Product Guide...
  • Page 107: Installing The Power Supply Support

    1. Set the power supply support into place in the system, lining up the guide pins in the chassis with the corresponding guide holes in the power supply support. See the figure below. AF001246 Figure 86. Setting the Power Supply Support into Place ® Intel Server System SR9000MK4U Product Guide...
  • Page 108: Figure 87. Tightening The Power Supply Support Screws

    ✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 109: Installing And Removing The Hard Drive Backplane Cover

    — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the hard drive backplane cover. For instructions, see “Installing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 110: Installing The Hard Drive Backplane Cover

    Figure 89. Installing the Hard Drive Backplane Cover 2. Push down on the backplane cover until it snaps into place. 3. Verify that two levers on top are latched, as shown by letter “A” below. ® Intel Server System SR9000MK4U Product Guide...
  • Page 111: Installing And Removing The Kvm Card

    The power supply filler panel, if one is installed. For instructions, see “Installing a Power Supply” on page 68. Follow step 2 only. • The power supply box. For instructions, see “Removing the Power Supply Box” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 112: Installing The Kvm Card

    Remove these components, in order, before beginning the steps below. 1. Line up the KVM card with the socket on the server board. Press the card firmly into place. Use caution so you do not bend or twist the KVM card. ® Intel Server System SR9000MK4U Product Guide...
  • Page 113: Installing And Removing The Pci Card Divider

    “Removing the Power Supply Box” on page • The KVM card, if it is installed. For instructions, see “Removing the KVM Card” on page • All installed PCI cards. For instructions, see “Removing a PCI Card” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 114: Figure 92. Removing The Pci Card Divider

    3. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the PCI card divider. For instructions, see “Installing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 115: Installing The Pci Card Divider

    1. Insert the two guides of the PCI divider into two guide holes near the bottom of the system. 2. Verify that the guides align with the guide holes in the chassis. Press down on the divider until it snaps into place. AF001232 Figure 93. Installing the PCI Divider ® Intel Server System SR9000MK4U Product Guide...
  • Page 116: Figure 94. Locating The Cpu1 / Cpu2 Mvr Connection

    ✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 117: Installing And Removing The Air Flow Guide

    After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Air Flow Guide” on page 97 to replace your air flow guide. ® Intel Server System SR9000MK4U Product Guide...
  • Page 118: Figure 95. Removing The Air Flow Guide

    2. Determine your next course of action and refer to the appropriate steps: — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the air flow guide. For instructions, see “Installing the Air Flow Guide” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 119: Installing The Air Flow Guide

    — If you are following these steps as part of another procedure, return to that procedure. — If you are ready to re-assemble your server system, install the following items, in order: ✧ The PCI card divider. For instructions, see “Installing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 120: Installing And Removing The Fan Box

    “Removing the KVM Card” on page • All installed PCI cards. For instructions, see “Removing a PCI Card” on page • The PCI card divider. For instructions, see “Removing the PCI Card Divider” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 121: Figure 97. Loosening The Exterior Screws

    Fan Box” on page 101 to replace your fan box. 1. Loosen one screw on each side of the system, as shown by letter “A” in the figure below. AF001221 Figure 97. Loosening the Exterior Screws ® Intel Server System SR9000MK4U Product Guide...
  • Page 122: Figure 98. Loosening The Interior Screws

    2. Loosen the two captive screws on the interior of the system, as shown by the figure below. AF001222 Figure 98. Loosening the Interior Screws 3. Lift the fan box from the system, as shown below. AF001223 Figure 99. Lifting the Fan Box from the System ® Intel Server System SR9000MK4U Product Guide...
  • Page 123: Installing The Fan Box

    AF001229 Figure 100. Installing the Fan Box ® Intel Server System SR9000MK4U Product Guide...
  • Page 124: Figure 101. Tightening The Internal Fan Box Screws

    Figure 101. Tightening the Internal Fan Box Screws 3. Tighten the two external screws, one at each side of the system, as shown by the figure below. AF001230 Figure 102. Tighten the External Fan Box Screws ® Intel Server System SR9000MK4U Product Guide...
  • Page 125: Installing And Removing The Hard Drive Backplane

    “Removing a Hard Drive” on page 40. Follow steps 1 through 3 only. • The front control panel and optical drive assembly. For instructions, see “Removing the Front Control Panel and Optical Drive Assembly” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 126 After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Hard Drive Backplane” on page 107 to replace your hard drive backplane. ® Intel Server System SR9000MK4U Product Guide...
  • Page 127: Table 18. Loosening The Hard Drive Backplane Screws

    1. Disconnect all cables from the hard drive backplane. 2. Remove the four screws from the hard drive backplane. See the following figure. AF001225 Table 18. Loosening the Hard Drive Backplane Screws ® Intel Server System SR9000MK4U Product Guide...
  • Page 128: Figure 103. Removing The Hard Drive Backplane From System

    — If you are following these steps as part of another procedure, return to that procedure. — Reinstall the hard drive backplane or install a replacement hard drive backplane. For instructions, see “Installing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 129: Installing The Hard Drive Backplane

    “B” in the figure. 2. Press down on the backplane to engage the 12 chassis hooks with the backplane. See letter “C” in the figure. AF001227 Figure 104. Installing the Hard Drive Backplane ® Intel Server System SR9000MK4U Product Guide...
  • Page 130: Figure 105. Attaching The Hard Drive Backplane To The System

    ✧ The KVM card, if it is installed. For instructions, see “Installing the KVM Card” on page ✧ All installed PCI cards. For instructions, see “Installing a PCI Card” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 131 38. Follow steps 7 through 9 only, unless you also need to install hard drives into the carriers. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ✧ The front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 132: Installing And Removing A Processor

    The following figure shows the components of the processor assembly. Refer to this figure as needed during the installation process to identify the components discussed in this section. AF001249 Processor Spring shroud Heat sink Bolster plate Spring clip Figure 106. Processor Assembly Components ® Intel Server System SR9000MK4U Product Guide...
  • Page 133: Removing A Processor

    After completing these steps, continue with the steps that directed you to this section, or follow the steps under “Installing the Processor” on page 113 to replace your processor. ® Intel Server System SR9000MK4U Product Guide...
  • Page 134: Figure 107. Removing The Mvr Handles

    3. Use a Torx-15 screwdriver to loosen the four screws on the corners of the MVR. See letter “B” in the figure. AF001252 Figure 108. Loosening the MVR Screws 4. Lift the MVR straight up from the system to remove it. ® Intel Server System SR9000MK4U Product Guide...
  • Page 135: Installing The Processor

    • The power supply box. For instructions, see “Removing the Power Supply Box” on page • Remove the hard drive backplane cover. For instructions, see “Removing the Hard Drive Backplane Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 136: Figure 109. Exposing The Thermal Interface Material

    Do not touch the processor pins with either your hands or with the pin shroud. • The pin shroud is fragile. Use caution when installing it. Excessive flex will break the pin shroud. ® Intel Server System SR9000MK4U Product Guide...
  • Page 137: Figure 110. Installing The Pin Shroud Over The Processor

    5. Set the spring clip into place on the processor as shown below. The rounded edge of the spring clip should be positioned below the pin shroud. AF001264 Figure 111. Installing the Spring Clip ® Intel Server System SR9000MK4U Product Guide...
  • Page 138: Figure 112. Setting The Processor Over The Heat Sink

    8. Use a Tork-15 screwdriver to tighten the four screws on the spring clip to secure the processor to the heat sink. Use a fastening torque of 0.45[N.m] (4.61[kgf.cm]. See the figure below. AF001259 Figure 113. Securing the Processor to the Heat Sink ® Intel Server System SR9000MK4U Product Guide...
  • Page 139: Figure 114. Installing The Bolster Plate Onto The Processor

    Figure 114. Installing the Bolster Plate onto the Processor 10. Make sure the processor lock on the main board is in the unlocked position. See the figure below. AF001267 Figure 115. Making Sure the Processor Socket is Unlocked ® Intel Server System SR9000MK4U Product Guide...
  • Page 140: Figure 116. Setting The Processor Assembly Into Place Over The Processor Socket

    13. Use a Torx-15 screwdriver to tighten the four screws on the corners of the heat sink. Use a torque level of 0.68[N.m] (6.9[kghf.cm]). See letter “B” in the figure. AF001269 Figure 117. Attaching the Processor and Heat Sink to the Main Board ® Intel Server System SR9000MK4U Product Guide...
  • Page 141: Figure 118. Removing The Protective Cover From The Lga Terminal

    Figure 118. Removing the Protective Cover from the LGA Terminal 15. Align the LGA terminal of the MVR with the LGA terminal pad of the processor assembly. AF001272 Figure 119. Setting the MVR into Place on the Processor Assembly ® Intel Server System SR9000MK4U Product Guide...
  • Page 142: Figure 120. Attaching The Mvr To The Processor Assembly

    Figure 120. Attaching the MVR to the Processor Assembly 18. Press the MVR handles into place on each side of the MVR. See the figure below. AF001274 Figure 121. Installing the Handles onto the MVR ® Intel Server System SR9000MK4U Product Guide...
  • Page 143 ✧ The power supply filler panel, if necessary. For instructions, see “Removing a Power Supply” on page 70. Follow step 4 only. ✧ The top cover. For instructions, see “Installing the Top Cover” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 144: Disassembling A Processor Assembly

    4. Verify that the processor lock is in the unlocked position. See letter “C”. 5. Lift the processor and heat sink assembly straight up to remove it from the server. AF001255 Figure 123. Loosening the Heat Sink Screws ® Intel Server System SR9000MK4U Product Guide...
  • Page 145: Figure 124. Removing The Bolster Plate From The Processor

    Figure 124. Removing the Bolster Plate from the Processor 7. Use a Torx-15 screwdriver to loosen four spring clip screws. See letter “A” in the following figure. AF001259 Figure 125. Removing the Processor from the Heatsink ® Intel Server System SR9000MK4U Product Guide...
  • Page 146: Figure 126. Removing The Spring Clip

    • The pin shroud is fragile. Use caution when removing it. Excessive flex will break the pin shroud. 11. Remove the pin shroud. AF001273 Figure 127. Removing the Pin Shroud from the Processor ® Intel Server System SR9000MK4U Product Guide...
  • Page 147: Installing And Removing The Mounting Plate

    For instructions, see “Removing a Processor” on page 111. ® Intel Server System SR9000MK4U Product Guide...
  • Page 148: Figure 128. Lifting The Mounting Plate From The System

    3. Lift the mounting plate from the system. AF001242 Figure 128. Lifting the Mounting Plate from the System 4. Install a replacement mounting plate. For instructions, see “Installing the Mounting Plate” on page 127. ® Intel Server System SR9000MK4U Product Guide...
  • Page 149: Installing The Mounting Plate

    “Installing the Fan Box” on page 101. — All installed fans. For instructions, see “Installing a Fan” on page — The air flow guide. For instructions, see “Installing the Air Flow Guide” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 150 38. Follow steps 7 through 9 only, unless you also need to install hard drives into the carriers. — The top cover. For instructions, see “Installing the Top Cover” on page — The front bezel. For instructions, see “Installing the Front Bezel” on page ® Intel Server System SR9000MK4U Product Guide...
  • Page 151: Installing And Removing Chassis Handles

    Figure 130. Attaching the Chassis Handles Removing Chassis Handles 1. Loosen two screws that hold each handle assembly in place. 2. Lift the handle assembly from the chassis. 3. Repeat steps 1 - 2 for each handle. ® Intel Server System SR9000MK4U Product Guide...
  • Page 152 ® Intel Server System SR9000MK4U Product Guide...
  • Page 153: Chapter 4: Configuration Software And Utilities

    Configuration Software and Utilities The Extensible Firmware Interface (EFI) Boot Manager The EFI boot manager enables the user to control the booting environment of server. After power is on, the boot manager activates the system with various ways according to the boot option settings.
  • Page 154: Table 19. Boot Maintenance Menu Options

    2. Press the <Enter> key. 3. Type the name of the EFI application to add 4. Press the <Enter> key. 5. Select [Save to NVRAM]. 6. Select [Exit] to return to the Boot Manager. ® Intel Server System SR9000MK4U Product Guide...
  • Page 155 3. Press the <b> key to start this option at the next time. Press the <r> key to reset. 4. Select [Save to NVRAM]. 5. Select [Exit] to return to the Boot Manager. ® Intel Server System SR9000MK4U Product Guide...
  • Page 156: The Extensible Firmware Interface (Efi) Shell

    The details of EFI shell utility is provided by typing “help” and press the <Enter> key during EFI shell operation. In addition to basic shell commands in EFI shell, the user can create original commands and EFI applications in EFI environment. ® Intel Server System SR9000MK4U Product Guide...
  • Page 157: Table 20. Efi Shell Commands

    Exits the EFI shell. Repeats a series of commands according to the condition. goto label Creates batch file that jumps to another label. guid [-b] Displays all GUIDs under the EFI environment. ® Intel Server System SR9000MK4U Product Guide...
  • Page 158 [hh:mm[:ss]] Displays or sets the time of the system. type [-a|-u] [-b] file [file...] Displays the contents of a file. Displays version information. vol [fs] [Volume Label] Displays volume information of a file. ® Intel Server System SR9000MK4U Product Guide...
  • Page 159: Lsi* Sas Utility

    MPT Firmware Revision 0.07.07.00-IT SAS Address 500605B0:00016CA0 Status Enabled Boot Support [Enabled BIOS & OS] SAS Topology Advanced Adapter Properties Esc = Exit Menu F1/Shift+1 = Help Enter = Select Item -/+ = Change Item ® Intel Server System SR9000MK4U Product Guide...
  • Page 160 5. Select the hard drive and press the <D> key. LSI Logic MPT Setup Utility 2.00.06.00 SAS Topology -- SAS1068 Device Identifier Device SAS1068(09:01:00) Info Controller Direct Attach Devices Expander FUJITSU MAX3036RC 2101 Esc=Exit F1=Help M=More Keys D=Device Properties ® Intel Server System SR9000MK4U Product Guide...
  • Page 161 Format may take hours to complete and cannot be stopped. Press the 'F' key to begin format or any other key to exit. Elapsed Time: 00:00:00 Percent Complete 100% /----------------------------------------\ \----------------------------------------/ Esc=Exit F1=Help M=More Keys ® Intel Server System SR9000MK4U Product Guide...
  • Page 162: Clearing The Cmos

    3. Hold down the reset button until the system LED begins to flash. 4. Power on the system. Upgrading the Firmware The FWUPDATE utility updates the SAL/BMC and writes sensor data records to the ® Intel Server System SR9000MK4U. A FWUPDATE is performed as an EFI shell command. ® Intel...
  • Page 163: Figure 131. Firmware Update Block Diagram

    ROM#0 Copied to internal flash by BMC Integrated ROM file (The file 512KB reset sequence. that integrates the update ROM data.) BMC external SAL Spool flash AF001197 Figure 131. Firmware Update Block Diagram ® Intel Server System SR9000MK4U Product Guide...
  • Page 164: How To Use Fwupdate

    Use ROM image data IA64_640.ROM in fs0 root directory. fwupdate fs0:\work\IA64_640.ROM; Use ROM image data IA64_640.ROM in fs0:work directory. fwupdate fs0:IA64_640.ROM; (not recommend) Command works if fs0 is the current drive Figure 132. FWUPDATE File Path Example ® Intel Server System SR9000MK4U Product Guide...
  • Page 165: Table 21. Command Line Description

    Updates only SAL in FWH and SAL Spool. /b or /B Updates only BMC in external flash. /n or /N Does not take over NVM area. (Invalid when /B or /S is specified.) ® Intel Server System SR9000MK4U Product Guide...
  • Page 166: Execution Screen

    Execution Screen fs0:>fwupdate fw_01-02_01-03.rom[Enter] Firmware Update Utility Ver 1.0 Copyright (C) 1996-2000 Intel Corporation. All rights reserved. ************************************************************ Copyright (c) Hitachi, Ltd, 2000-2005. All rights reserved. ************************************************************ Build Date: Tue Feb 27 16:22:51 2005 *Fwupdate is providing update services* File: fs0:\fw_01-02_01-03.rom Size: 9,371,904 Bytes Reading file fs0:\fw_01-02_01-03.rom 100% Done!
  • Page 167: Using System Setup

    Before modifying any settings, be sure that the current values are recorded. When the restore of default values are required after CMOS clear, for example, the user must execute the setup again. By referring to the stored original settings, the restore operation may become easier. ® Intel Server System SR9000MK4U Product Guide...
  • Page 168: Navigating Setup Utility Screens

    Stores the changed values in CMOS, and exits setup. Clicking on the Exit menu item causes the system to prompt the user for a Yes or No response. Yes: Saves the changes and reboots the system. No: Aborts the action. ® Intel Server System SR9000MK4U Product Guide...
  • Page 169: Table 24. Main Setup Screen

    AC power recovery even if on is selected as the Power On option. Use the power button to power on the system, and then press and release the power button to shut down the server without forcing it into the power off state. ® Intel Server System SR9000MK4U Product Guide...
  • Page 170: Table 25. Processor Screen

    Enables / disables memory mirroring. Enable Failed Memory [Enable] Enable: Deconfigures the failure-detected memory and Deconfiguration boots. Disable: Cancels boot and turns off the power. Disable NUMA [Enable] Enables / disables NUMA memory configuration. Disable ® Intel Server System SR9000MK4U Product Guide...
  • Page 171: Table 27. Devices Screen

    Table 27 describes the menu items available on the Devices screen. Default values appear in brackets. Table 27. Devices Screen Primary Menu Item Sub Menu Item Options Description Onboard VGA [Enable] Enables / disables on-board VGA. Disable ® Intel Server System SR9000MK4U Product Guide...
  • Page 172: Table 28. Server Management Screen

    EFI console input/output to COM1. Does not provide SPCR or HCDP to OS. When the valid VGA is not mounted, “Enable” is set. COM1 Speed 9600 bps Uses the communication speed specified when console redirection is valid. [19200bps] ® Intel Server System SR9000MK4U Product Guide...
  • Page 173: Configuring Serial-Over Lan

    1. Open “System Setup Menu” on the screen. 2. Choose “Server Management”: System Setup Menu Main Processor Memory Devices Server Management Security Save changes and Exit Discard changes and Exit Restore Defaults Exit ® Intel Server System SR9000MK4U Product Guide...
  • Page 174 EFI Utility User’s Guide. 8. Bundled management software will use User #10. Do not use this user number if you plan to use the management software that is included with your server system. ® Intel Server System SR9000MK4U Product Guide...
  • Page 175: Chapter 5: Troubleshooting

    Troubleshooting Initial Troubleshooting Steps ® The Intel Server System SR9000MK4U implements indicators to display the system status. These are useful as a first step in identifying a problem. Begin troubleshooting by using the table below to view symptoms and solutions. If you do not find the answer you need in the table, continue with the information that follows the table.
  • Page 176 Disconnect and reconnect the USB cable and retry. Replace the keyboard. Mouse Mouse does not work Check that the mouse USB cable is normally. properly connected. Disconnect and reconnect the USB cable and retry. Replace the mouse. ® Intel Server System SR9000MK4U Product Guide...
  • Page 177 I/O card is not properly Check that the I/O card is installed into recognized. Attention LED the slot properly. (yellow) blinks. Check that the variety of I/O card corresponds to the installed slot. ® Intel Server System SR9000MK4U Product Guide...
  • Page 178: Collecting System State Information

    Power Off Initialization EFI Shell Working OS Working System Hang State transition within normal operation State transition due to a failure AF001275 Figure 134. State Transition Diagram ® Intel Server System SR9000MK4U Product Guide...
  • Page 179 If you reproduced the problem, read the POST code. For instructions, see “How to Read the POST Codes” on page 159. If the system seems to have moved to the system hang status during the procedure, see “System Hang Status” on page 159. ® Intel Server System SR9000MK4U Product Guide...
  • Page 180 If you reproduced the problem, read the POST code. For instructions, see “How to Read the POST Codes” on page 159. If the system seems to have moved to a system hang status, follow the steps under System Hang Status, below. ® Intel Server System SR9000MK4U Product Guide...
  • Page 181: How To Read The Post Codes

    How to Read the POST Codes The POST code decimal number is located inside the chassis at the right side. See the figure below. AF001270 Figure 135. Location of POST Code LED ® Intel Server System SR9000MK4U Product Guide...
  • Page 182: How To Use Selview To Read The System Event Log

    9. Click Save. 10. Select “Security” in the tree display section. 11. Select “Save Log File As” from the Operation menu on the menu bar. 12. The “Save Security Log As” dialog box opens. ® Intel Server System SR9000MK4U Product Guide...
  • Page 183 27. From the command prompt, execute. dir \<WINDOWS>\system32\drivers > <X>:\drivers.txt 28. Type “exit” to close the command prompt. 29. Use Explorer* to confirm that the following files have been created on the external storage: system.evt system.csv security.evt ® Intel Server System SR9000MK4U Product Guide...
  • Page 184: Taking Corrective Action

    30. Use Notepad to confirm the following files contain some texts: system32.txt drivers.txt 31. Stop the external storage and remove the device from the system. Taking Corrective Action “POST Codes” on page 171 for suggested corrective actions. ® Intel Server System SR9000MK4U Product Guide...
  • Page 185: Appendix A: Console Setup

    Appendix A: Console Setup On-board VGA ® The Intel Server System SR9000MK4U server can output the SAL and EFI displays to on-board VGA. This subsection describes how to enable/disable the on-board VGA. 1. Select System Setup from the Boot Maintenance Menu of the EFI Boot Manager.
  • Page 186 Examine and set VGA parameters. Onboard VGA [Enable] Exit Use Enter to change value. 5. Select Exit twice and return to the System Setup Menu. 6. Select Save changes and Exit to end the System Setup. ® Intel Server System SR9000MK4U Product Guide...
  • Page 187: Serial Console

    Serial Console ® The Intel Server System SR9000MK4U server supports headless function that redirects the VGA output and keyboard input of SAL and EFI to the COM1 port input/output. This subsection describes how to enable/disable the headless function and how to set baud rate.
  • Page 188 6. Select COM1 Speed and set it to 9600 bps or 19200 bps. Set the baud rate that is set to the terminal connected to COM1 port. 7. Select Exit three times to return to the System Setup Menu. 8. Select Save changes and Exit to end the System Setup utility. ® Intel Server System SR9000MK4U Product Guide...
  • Page 189: Appendix B: Cabling

    Appendix B: Cabling This appendix provides a a brief guideline about how to correctly attach and detach cables to prevent damage to the cable, or to the connector on the cable end or the server board. This appendix also provides photographs of the cable connections in the server system. Working with Ribbon Cables Make sure to detach (or attach) the flat cable assembly from the main board according to the following instructions.
  • Page 190: Cable Connections

    Note: The figure above shows the system with the power supply box removed. AF001435 SATA 0 - 3 connector on hard drive SATA 4 - 7 connector on hard drive backplane backplane Figure 137. SATA Connections on Hard Drive Backplane ® Intel Server System SR9000MK4U Product Guide...
  • Page 191: Figure 138. Ide Connection And Cable Routing

    MVR connector for processors 1 and 2 MVR connector for processors 3 and 4 Figure 139. MVR Connectors Note: The figure above shows the system with the PCI card divider and the power supply box removed. ® Intel Server System SR9000MK4U Product Guide...
  • Page 192 AF001438 Control panel power connection on Control panel data connector hard drive backplane on server board Control panel data connector on Control panel power cable on hard drive backplane server board ® Intel Server System SR9000MK4U Product Guide...
  • Page 193: Appendix C: Post Codes

    Appendix C: POST Codes Table 31. POST Codes Generated by the BMC and Logged at the Seven Segment LED Operation to Code Descriptions Classification Recover reserved SRAM Check Started Progress SRAM Check Completed Progress Active side BMC F/W binary file checking Progress Spool side BMC F/W binary file checking Progress...
  • Page 194 Task booting process started Progress reserved reserved reserved reserved reserved reserved reserved Message handler started Progress PDK initialization process started Progress Task generation process started Progress BMC initialization completed Progress reserved reserved reserved reserved reserved reserved ® Intel Server System SR9000MK4U Product Guide...
  • Page 195 CPU2 I2C Access Error (PIROM) Error, error event logged to SEL CPU2 I2C Access Error (Temperature Monitor) Error, error event SEL List logged to SEL CPU3 Thermal Trip Error, error event logged to SEL ® Intel Server System SR9000MK4U Product Guide...
  • Page 196 PS0 Configuration Error (Insufficient Error, error event Resources) logged to SEL PS1 Configuration Error (Insufficient Error, error event Resources) logged to SEL PS1 Configuration Error (Different Type) Error, error event logged to SEL ® Intel Server System SR9000MK4U Product Guide...
  • Page 197 SEL CPU1 Configuration Error (Installation Rule) Error, error event logged to SEL CPU2 Configuration Error (Installation Rule) Error, error event logged to SEL Chassis Intrusion detected Error, error event logged to SEL reserved ® Intel Server System SR9000MK4U Product Guide...
  • Page 198 SEL MB Illegal Machine Check Interrupt Error, error event logged to SEL reserved HDDPL I2C Access Error (SEEPROM) Error, error event logged to SEL reserved reserved reserved reserved reserved reserved reserved reserved reserved ® Intel Server System SR9000MK4U Product Guide...
  • Page 199: Table 32. Post Codes Generated By Sal And Logged At The Seven Segment Led

    Segment LED Operation to Code Description Recover BSP selection Check previous SEL W Mutex service initialization NVSDA service initialization AP synchronization control Chipset low-level initialization PAL status check RTC initialization Super IO initialization ® Intel Server System SR9000MK4U Product Guide...
  • Page 200 Initialize interrupt vector table (IVT) Multiple host bus bridge initialization PCI initialization Transfer to virtual mode IA32BIOS execution Transfer to physical mode Initialize IDE controller PCI initialization after returning from IA32 BIOS RAS late initialization ® Intel Server System SR9000MK4U Product Guide...
  • Page 201: Table 33. Error Post Codes Generated By Sal

    Error 0x8006 Processor failure Error 0x8008 Unexpected failure Error 0x800A Unexpected failure Error 0x800B Unexpected failure Error 0x800C Unexpected failure Error 0x8014 Unexpected failure Error 0x8015 Unexpected failure Error 0x8016 Unexpected failure Error ® Intel Server System SR9000MK4U Product Guide...
  • Page 202 0xC0E3 Unexpected failure in the SAL machine Error check handler. 0xC0E4 Unexpected failure in the SAL machine Error check handler. 0xC0E6 Unexpected failure Error 0xA108 Unexpected failure in the machine Error check handler. ® Intel Server System SR9000MK4U Product Guide...
  • Page 203: Appendix D: Installation/Assembly Safety Instructions

    Appendix D: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.
  • Page 204 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR9000MK4U Product Guide...
  • Page 205: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR9000MK4U Product Guide...
  • Page 206 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR9000MK4U Product Guide...
  • Page 207: Français

    Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR9000MK4U Product Guide...
  • Page 208 Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. ® Intel Server System SR9000MK4U Product Guide...
  • Page 209: Español

    Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación. ® Intel Server System SR9000MK4U Product Guide...
  • Page 210 También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. ® Intel Server System SR9000MK4U Product Guide...
  • Page 211: Italiano

    Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato ® Intel Server System SR9000MK4U Product Guide...
  • Page 212 Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. ® Intel Server System SR9000MK4U Product Guide...
  • Page 213 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR9000MK4U Product Guide...
  • Page 214 ® Intel Server System SR9000MK4U Product Guide...
  • Page 215: Appendix E: Safety Information

    Appendix E: Safety Information Warning Labels ® The Intel Server System SR9000MK4U contains several warning labels on the interior and exterior of the server system. These warning labels indicate components that present a potential danger. Do not remove these warning labels. The following diagrams show the labels and their locations.
  • Page 216: Figure 141. Caution: Server System Is Heavy

    AF001422 Figure 141. Caution: Server System is Heavy The warnings labels at the rear of the server chassis contains voltage information. AF001423 Figure 142. Caution: System Contains Areas of High Voltage ® Intel Server System SR9000MK4U Product Guide...
  • Page 217: English

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 218: Safety Warnings And Cautions

    The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation. ® Intel Server System SR9000MK4U Product Guide...
  • Page 219: Site Selection

    Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR9000MK4U Product Guide...
  • Page 220: Power And Electrical Warnings

    A separate AC cord is required for each system power supply. ® • Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 221: System Access Warnings

    Caution: To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the fan guard in place. ® Intel Server System SR9000MK4U Product Guide...
  • Page 222: Rack Mount Warnings

    After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. ® Intel Server System SR9000MK4U Product Guide...
  • Page 223: Other Hazards

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR9000MK4U Product Guide...
  • Page 224: Deutsch

    Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 225: Zielbenutzer Der Anwendung

    Telekommunikationskabel zum Modem abziehen. • Eine ordnungsgemäß geerdete Wandsteckdose muß vorhanden sein. • Ausreichender Freiraum für den Zugang zu den Netzkabeln, da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind. ® Intel Server System SR9000MK4U Product Guide...
  • Page 226: Handhabung Von Geräten

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 227: Warnhinweise Für Den Systemzugang

    Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder ® Intel Server System SR9000MK4U Product Guide...
  • Page 228: Warnhinweise Für Racks

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR9000MK4U Product Guide...
  • Page 229: Andere Gefahren

    • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR9000MK4U Product Guide...
  • Page 230: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 231: Domaines D'utilisation Prévus

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR9000MK4U Product Guide...
  • Page 232: Alimentation Et Avertissements En Matière D'électricité

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 233: Avertissements Sur L'accès Au Système

    Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. ® Intel Server System SR9000MK4U Product Guide...
  • Page 234: Avertissements Sur Le Montage En Rack

    Mettez la pile au rebut en vous conformant aux réglementations locales. N’essayez pas de recharger une pile. N’essayez pas de démonter, de percer ou d’endommager la pile d’une quelconque façon. ® Intel Server System SR9000MK4U Product Guide...
  • Page 235 Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. ® Intel Server System SR9000MK4U Product Guide...
  • Page 236: Español

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 237: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. ® Intel Server System SR9000MK4U Product Guide...
  • Page 238: Advertencias De Alimentación Y Eléctricas

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 239: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. ® Intel Server System SR9000MK4U Product Guide...
  • Page 240: Advertencias Sobre El Montaje En Bastidor

    Deseche las baterías respetando la normativa local. No intente recargar la batería. No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería. ® Intel Server System SR9000MK4U Product Guide...
  • Page 241 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR9000MK4U Product Guide...
  • Page 242 简体中文 服务器安全信息 本文档适用于 Intel® 服务器主板、Intel® 服务器机箱(基座和机架固定件)和已安装的外设。为减少人身伤害、电击、火 以及设备毁坏的危险,请在安装或维护 Intel® 服务器产品之前阅读本文档并遵循本指南中的所有警告和预防措施。 如果本文档中的信息与特定产品的随附信息或 Web 站点信息之间存在不一致,请以产品文档为准。 服务器须由合格的技术人员进行集成和维护。 必须遵守本指南的规定和服务器手册的装配指导,以确保符合现有的产品认证和 批。仅使用本指南中描述和规定的指定组件。使用其他产品 / 组件将使产品的 认证和其他管理审批无效,并可能导致产品不符合销售地的产品法规。 安全警告与注意事项 为避免人身伤害与财产损失,安装本产品之前,请阅读以下所有安全指导和信息 下面所列的安全符号可能在整个文档中使用并可能标注于产品和 / 或产品包装之上。 注意 表示如果无视此“? ? ? 项”? ? ? ? ? ? ? 轻微人身伤害或财产损失的危 警告 表示如果无视此“? ? ”? ? ? ? ? ? ? 严重人身伤害的危险。...
  • Page 243 • 远离振动源或物理震动。 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 ® Intel Server System SR9000MK4U Product Guide...
  • Page 244 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 ® Intel Server System SR9000MK4U Product Guide...
  • Page 245 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 ® Intel Server System SR9000MK4U Product Guide...
  • Page 246 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 ® Intel Server System SR9000MK4U Product Guide...
  • Page 247: Appendix F: Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out a server issue report form.For the fastest service, please submit your form via the Internet.
  • Page 248: Latin America

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR9000MK4U Product Guide...
  • Page 249 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR9000MK4U Product Guide...
  • Page 250 ® Intel Server System SR9000MK4U Product Guide...
  • Page 251: Appendix G: Regulatory And Compliance Information

    (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information please contact your local Intel Representative.
  • Page 252: Product Emc Compliance - Class A Compliance

    Product EMC Compliance - Class A Compliance Note: Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits • FCC / ICES-003 - Emissions (USA/Canada) Verification •...
  • Page 253: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 254: Industry Canada (Ices-003)

    Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR9000MK4U Product Guide...
  • Page 255: Bsmi (Taiwan)

    RRL (Korea) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
  • Page 256: Regulated Specified Components

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) UL listed.
  • Page 257: Restriction Of Hazardous Substances (Rohs) Compliance

    Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.
  • Page 258 ® Intel Server System SR9000MK4U Product Guide...

This manual is also suitable for:

Sr9000mk4u

Table of Contents