Manager - Juniper NETWORK AND SECURITY MANAGER 2010.3 - ADMINISTRATION GUIDE REV1 Administration Manual

Table of Contents

Advertisement

Disassociating Enforcement Points from an Infranet Controller in the UAC Manager
Resolving Configuration Conflicts with the Infranet Controller in the UAC Manager
Copyright © 2010, Juniper Networks, Inc.
NOTE: If you delete an IC or EP device, all related IC-EP associations are removed from
the UAC Manager, and the configuration in the device is not modified. Therefore, first
remove IC-EP and 802.1X port associations from the UAC Manager before you delete
an IC or EP. This ensures that configuration changes take effect in the device.
To disassociate Enforcement Points (EP) from a selected Infranet Controller (IC):
Select from the EP table the EPs to disassociate from the IC.
1.
Select the Delete button (-) above the Enforcement Points table.
2.
Select the check box to run an Update Device task, which pushes configuration
3.
changes on both the IC and EPs. The configuration status of the EPs changes to
Managed, InSync.
Select the check box to run a Summarize Delta Config task that ensures the
4.
association between the IC and EP in the application database. The configuration
status of these devices becomes Managed, NSM Changed.
Select OK. The selected EPs are removed from the IC.
5.
Before you resolve configuration conflicts, perform an "Import Device" to identify the
actual conflicts in the configuration. To ensure that configurations made in the Infranet
Controller (IC) device are reflected in the UAC Manager:
Select an IC and right-click on it
1.
Select
Resolve Config Mismatch
2.
Mismatch window opens displaying differences between the RADIUS client
configuration in the IC and the administered data in the UAC Manager.
Verify whether data currently administered in NSM by the UAC Manager is consistent
3.
with data in the RADIUS client device configuration.
Provide shared secret and IC port details. You cannot update information without
4.
this information.
Select the action to be performed:
5.
Select
Update UAC Manager
the IC.
Select
Update the Enforcement Point Association in the Infranet Controller
the data in the IC with data from the UAC Manager.
Select the check box to overwrite the shared secret in the device.
6.
Select the check box to run an Update Device task after you make an update.
7.
Select OK.
8.
Chapter 16: Unified Access Control Manager
from the dropdown menu. The Resolve Config
to update the UAC Manager data with the data from
to update
643

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network and security manager 2010.3

Table of Contents