Unit-Slot-Port Naming Convention; Using The "No" Form Of A Command - NETGEAR GSM7328Sv1 - ProSafe 24+4 Gigabit Ethernet L3 Managed Stackable Switch Cli Reference Manual

Layer-3 stackable switches, software version 7.3
Hide thumbs Also See for GSM7328Sv1 - ProSafe 24+4 Gigabit Ethernet L3 Managed Stackable Switch:
Table of Contents

Advertisement

Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches,

2.2.3 Unit-Slot-Port Naming Convention

7300S Series Stackable Switch software references physical entities such as cards and
ports by using a Unit-Slot-Port (USP) naming convention. The software also uses this
convention to identify certain logical entities, such as port-channel interfaces.
The slot number has two uses. In the case of physical ports, it identifies the card
containing the ports. In the case of logical and CPU ports it also identifies the type of
interface or port.
Table 2-3. Type of Slots
Slot Type
Physical slot numbers
Logical slot numbers
CPU slot numbers
The port identifies the specific physical port or logical interface being managed on a given
slot.
Table 2-4. Type of Ports
Port Type
Physical Ports
Logical Interfaces
CPU ports

2.2.4 Using the "No" Form of a Command

The
keyword is a specific form of an existing command and does not represent a new
no
or distinct command. Almost every configuration command has a
the
form to reverse the action of a command or reset a value back to the default. For
no
example, the
no shutdown
Use the command without the keyword
feature that is disabled by default.
Only the configuration commands are available in the
Overview
Description
Physical slot numbers begin with zero, and are allocated up to the
maximum number of physical slots.
Logical slots immediately follow physical slots and identify port-
channel (LAG) or router interfaces.
The CPU slots immediately follow the logical slots.
Description
The physical ports for each slot are numbered sequentially starting
from zero. For example, port one will be "0/1" with slot number
always as zero.
Port-channel or Link Aggregation Group (LAG) interfaces are
logical interfaces that are only used for bridging functions.
VLAN routing interfaces are only used for routing functions.
CPU ports are handled by the driver as one or more physical
entities located on physical slots.
configuration command reverses the shutdown of an interface.
to re-enable a disabled feature or to enable a
no
v4.1, October 2008
form. In general, use
no
form.
no
2-5

Advertisement

Table of Contents
loading

Table of Contents