Exec-Timeout - SMC Networks 6824MPE INT Management Manual

24-port fast ethernet poe switch
Hide thumbs Also See for 6824MPE INT:
Table of Contents

Advertisement

Example
To set the timeout to two minutes, enter this command:
Console(config-line)#timeout login response 120
Console(config-line)#

exec-timeout

Use this command to set the interval that the system waits until user input is
detected. Use the no form to restore the default.
Syntax
exec-timeout [seconds]
no exec-timeout
seconds - Integer that specifies the number of seconds.
(Range: 0 - 65535 seconds; 0: no timeout)
Default Setting
CLI and Telnet: 600 seconds (10 minutes)
Command Mode
Line Configuration
Command Usage
• If user input is detected within the timeout interval, the session is kept
open; otherwise the session is terminated.
• This command applies to both the local console and Telnet connections.
• The timeout for Telnet cannot be disabled.
• Using the command without specifying a timeout restores the default
setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#exec-timeout 120
Console(config-line)#