TigerSwitch 10/100 24-Port Fast Ethernet Switch N 24 10BASE-T/100BASE-TX auto MDI/MDIX ports N Optional 100BASE-FX or 1000BASE-X modules N 8.8 Gbps aggregate bandwidth N Non-blocking switching architecture N Spanning Tree Protocol N Up to eight port trunks N Port mirroring for non-intrusive analysis N QoS support for two-level priority N Full support for VLANs with GVRP N IP multicasting with IGMP snooping...
Page 3
TigerSwitch 10/100 Management Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 6 Hughes Irvine, CA 92618 November 2001 Pub. # 150000000600A Phone: (949) 707-2400...
Page 4
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC.
Management Protocol). This SNMP agent permits the switch to be managed from any PC in the network using in-band management software (such as SMC’s EliteView). The management agent also includes an embedded HTTP Web agent. This Web agent can be accessed using a standard Web browser from any computer attached to the network.
WITCH ANAGEMENT Required Connections Console Port (Out-of-Band) Connections Attach a VT100 compatible terminal or a PC running a terminal emulation program to the serial port on the switch’s rear panel. Use the null-modem cable provided with this package, or use a null modem connection that complies with the wiring assignments shown in Appendix B of this guide.
Page 13
2. Up to four simultaneous Telnet sessions are supported by this switch. 3. The on-board program only provides access to basic configuration functions. To access the full range of SNMP management functions, you must use SNMP- based network management software, such as SMC’s free EliteView software.
MMMM CCCCCCCCCCCCCC TigerSwitch 10/100 SMC6724L2 V1.04 10-23-2001 (c) Copyright Smc Technology Corp. User Name: Password : If this is your first time to log into the configuration program, then the default user names are “admin” and “guest,” with no password.
Page 16
ONSOLE NTERFACE You should define a new administrator password, record it and put it in a safe place. Select User Configuration from the Management Setup Menu and enter a new password for the administrator. Note that passwords can consist of up to 15 alphanumeric characters and are not case sensitive.
Page 17
CREEN After you enter the user name and password, you will have access to the system configuration program illustrated by the following menu map: System Information System Switch Information Information Menu IP Configuration IP Connectivity Test (Ping) HTTP Configuration Management Network Configuration Setup Menu Serial Port Configuration...
ONSOLE NTERFACE Main Menu With the system configuration program you can define system parameters, manage and control the switch and all its ports, or monitor network conditions. The screen below of the Main Menu and the table following it briefly describe the selections available from this program.
Page 19
Menu Description Management Setup Menu Network Configuration Includes IP setup, Ping facility, and HTTP (Web agent) setup. Serial Port Configuration Sets communication parameters for the serial port, including baud rate, console timeout, and screen data refresh interval. SNMP Configuration Activates authentication failure traps; configures community access strings and trap managers.
Page 20
ONSOLE NTERFACE Menu Description Network Monitor Menu Port Statistics Displays statistics on port traffic, including information from the Interfaces Group, Ethernet-like MIB, and RMON MIB. Layer 2 Address Table Contains the unicast address table. Bridge Menu Displays Spanning Tree information for the overall bridge and for specified ports.
YSTEM NFORMATION System Information Menu Use the System Information Menu to display a basic description of the switch, including contact information, and hardware/firmware versions. System Information Menu ======================= System Information ... Switch Information ... <OK> Use <TAB> or arrow keys to move. <Enter> to select. Menu Description System Information...
ONSOLE NTERFACE Displaying System Information Use the System Information screen to display descriptive information about the switch, or for quick system identification as shown in the following screen and table. System Information ================== System Description : TigerSwitch 10/100 (SMC6724L2) System Object ID : 1.3.6.1.4.1.202.20.19 System Up Time : 1270430 (0 day 3 hr 31 min 44 sec)
YSTEM NFORMATION Displaying Switch Version Information Use the Switch Information screen to display hardware/firmware version numbers for the main board, as well as the power status. Switch Information ================== Hardware Version : R01 Firmware Version : V1.04 Serial Number : 00-10-B5-DD-DF-C0 Port Number : 26 Internal Power Status...
ONSOLE NTERFACE Management Setup Menu After initially logging on to the system, adjust the communication parameters for your console to ensure a reliable connection Serial Port Configuration). Specify the IP addresses for the switch ( Network Configuration / IP Configuration), and then set the Administrator and User passwords ( User Configuration).
ANAGEMENT ETUP Menu Description TFTP Download Downloads new version of firmware to update your system (in-band). Configuration File Saves or restores configuration data based on the specified file. Changing the Network Configuration Use the Network Configuration menu to set the bootup option, configure the switch’s Internet Protocol (IP) parameters, or enable the onboard Web agent.
ONSOLE NTERFACE IP Configuration Use the IP Configuration screen to set the bootup option, or configure the switch’s IP parameters. The screen shown below is described in the following table. IP Configuration ================ Interface Type : Ethernet IP Address : 192.168.1.254 Subnet Mask : 255.255.255.0 Gateway IP : 0.0.0.0...
Page 27
ANAGEMENT ETUP Parameter Description IP State Specifies whether IP functionality is enabled via manual configuration, or set by Boot Protocol (BOOTP). Options include: USER-CONFIG - IP functionality is enabled based on the default or user specified IP Configuration. (This is the default setting.) BOOTP Get IP - IP is enabled but will not function until a BOOTP reply has been...
ONSOLE NTERFACE IP Connectivity Test (Ping) Use the IP Connectivity Test to see if another site on the Internet can be reached. The screen shown below is described in the following table. IP Connectivity Test (Ping) =========================== IP Address : 10.1.3.22 Test Times : 3 Success Failure...
ANAGEMENT ETUP HTTP Configuration Use the HTTP Configuration screen to enable/disable the onboard Web agent. HTTP Configuration ================== HTTP Server : ENABLED <Apply> <OK> <Cancel> Use <TAB> or arrow keys to move, <Space> to scroll options. Note: Port 80 is used for HTTP service. 2-15...
ONSOLE NTERFACE Configuring the Serial Port You can access the onboard configuration program by attaching a VT100 compatible device to the switch’s serial port. (For more information on connecting to this port, see “Required Connections” on page 1-2.) The communication parameters for this port can be accessed from the Serial Port Configuration screen shown below and described in the following table.
Page 31
ANAGEMENT ETUP Parameter Default Description Management Console Indicates that the port settings are for direct Mode Mode console connection. Baud Rate 19200 The rate at which data is sent between devices. Options: 9600, 19200 and 38400 baud. Data Bits 8 bits Sets the data bits of the RS-232 port.
ONSOLE NTERFACE Assigning SNMP Parameters Use the SNMP Configuration screen to display and modify parameters for the Simple Network Management Protocol (SNMP). The switch includes an onboard SNMP agent which monitors the status of its hardware, as well as the traffic passing through its ports.
ANAGEMENT ETUP Configuring Community Names The following figure and table describe how to configure the community strings authorized for management access. Up to 5 community names may be entered. SNMP Communities ================ Community Name Access Status public READ/WRITE ENABLED private READ ONLY ENABLED <APPLY>...
ONSOLE NTERFACE Configuring IP Trap Managers The following figure and table describe how to specify management stations that will receive authentication failure messages or other trap messages from the switch. Up to 5 trap managers may be entered. IP Trap Managers ================ IP Address Community Name...
ANAGEMENT ETUP User Log-in Configuration Use the User Configuration menu to restrict management access based on specified user names and passwords. There are two user types, Administrator and Guest. Only the Administrator has write access for parameters governing the SNMP agent. You should therefore assign a user name and password to the Administrator as soon as possible, and store it in a safe place.
Page 36
ONSOLE NTERFACE To add a new user, select <Add>. When you add a user, the following screen is displayed. Add User ======== User Name Password Access Right GUEST Console Access DISABLED Telnet Access DISABLED HTTP Access ENABLED <OK> <Cancel> Use <TAB> or arrow keys to move, other keys to make changes. Parameter Description User Name*...
Use the TFTP Download menu to load software updates to permanent flash ROM in the switch. The download file should be an SMC6724L2 binary file from SMC; otherwise the agent will not accept it. The success of the download operation depends on the accessibility of the TFTP server and the quality of the network connection.
ONSOLE NTERFACE Saving or Restoring the System Configuration Use the Configuration File menu to save the switch configuration settings to a file on a TFTP client. The file can be later downloaded to the switch to restore the switch’s settings. The success of the operation depends on the accessibility of the TFTP client and the quality of the network connection.
Page 39
ANAGEMENT ETUP Switch: Select <START> from the Configuration File menu. TFTP Client: Start transferring the configuration file from the TFTP client or the switch, and wait until the transfer completes. Saving and restoring switch configuration settings can be initiated by using any TFTP client utility, such as the command line utility included in Windows NT.
ONSOLE NTERFACE Device Control Menu The Device Control menu is used to control a broad range of functions, including port mode, port mirroring, port trunking, Spanning Tree, Virtual LANs, IP subnets, multicast filtering, and routing protocols. Each of the setup screens provided by these configuration menus is described in the following sections.
EVICE ONTROL Layer 2 Menu The Layer 2 menu contains options for port configuration, port mirroring, port trunking, static unicast address configuration and static multicast address configuration. These menu options are described in the following sections. Layer 2 Menu ============ Port Configuration ...
ONSOLE NTERFACE Configuring Port Parameters Use the Port Configuration menu to display or set communication parameters for any port or module on the switch, including administrative status, auto-negotiation, default communication speed and duplex mode, as well as flow control in use. Layer 2 Menu: Port Configuration (Port 1-12) ============...
Page 43
EVICE ONTROL Parameter Default Description Link Status Indicates if the port has a valid connection to an external device. Admin Enabled Allows you to disable a port due to abnormal Status behavior (e.g., excessive collisions), and then reenable it after the problem has been resolved.
Page 44
ONSOLE NTERFACE Parameter Default Description Flow Control Off Used to enable or disable flow control. Flow control can eliminate frame loss by “blocking” traffic from end stations or segments connected directly to the switch when its buffers fill. When enabled, back pressure is used for half duplex and IEEE 802.3x for full duplex.
EVICE ONTROL Using a Mirror Port for Analysis You can mirror traffic from any source port to a target port for real-time analysis. You can then attach a logic analyzer or RMON probe to the target port and study the traffic crossing the source port in a completely unobtrusive manner.
ONSOLE NTERFACE Configuring Port Trunks Ports can be combined into an aggregate link to increase the bandwidth of a network connection or to ensure fault recovery. You can configure trunks between any two SMC6724L2 or SMC6724L3 switches. Ports 1-24 on this switch can be grouped into a trunk consisting of two, four or eight ports, creating an aggregate bandwidth up to 400, 800 or 1600 Mbps when operating at full duplex.
Page 47
EVICE ONTROL You can use the Port Trunking Configuration screen to set up port trunks as shown below: Layer 2 Menu: Port Trunking Configuration ============ Index Port Count Port Number Trunk1 Trunk2 Trunk3 <OK> <Add> Use <TAB> or arrow keys to move. <Enter> to select. Parameter Description Index...
Page 48
ONSOLE NTERFACE For the extender modules (ports 25, 26), the possible port trunking combinations are set out belo Extender Module 100BASE-FX Can be trunked together. 1000BASE-SX, Can be trunked together, irrespective of media. 1000BASE-LX, 1000BASE-T To add a trunk, select <Add>. To delete a trunk, highlight the required entry and select Enter.
EVICE ONTROL Configuring the Static Unicast Address Table The Static Unicast Address Table can be used to assign the MAC address for a host device to a specific port on this switch. Static unicast addresses are never aged out, and cannot be learned on another port.
ONSOLE NTERFACE Configuring the Static Multicast Address Table The Static Multicast Address Table can be used to assign a destination MAC address (and the corresponding ports) to the VLAN group used for a specific multicast service. Static multicast addresses are never aged out, and traffic with these addresses can be forwarded only to ports specified in this table.
EVICE ONTROL Using the Bridge Menu The Bridge menu is used to configure settings for the Spanning Tree Algorithm, as well as the global bridge settings for GMRP (GARP Multicast Registration Protocol) and GVRP (GARP VLAN Registration Protocol), traffic class priority threshold, and address aging time.
ONSOLE NTERFACE Configuring Global Bridge Settings The following figure and table describe bridge configuration for STA, GMRP, GVRP, priority threshold, and address aging time. Bridge Configuration ==================== Spanning Tree :ENABLED GMRP :DISABLED Bridge Priority :32768 GVRP :DISABLED Hello Time (in seconds) Priority Threshold Forward Delay (in seconds) :15 Aging Time (in seconds):300...
Page 53
EVICE ONTROL Parameter Default Description Forward Delay 1 The maximum time (in seconds) the root device will wait before changing states (i.e., listening to learning to forwarding). This delay is required because every device must receive information about topology changes before it starts to forward frames.
Page 54
ONSOLE NTERFACE Parameter Default Description GVRP Disabled GARP VLAN Registration Protocol (GVRP) defines a way for switches to exchange VLAN information in order to register VLAN members on ports across the network. This function should be enabled to permit automatic VLAN registration, and to support VLANs which extend beyond the local switch.
EVICE ONTROL Configuring STA for Ports The following figure and table describe port STA configuration. Spanning Tree Port Configuration (Port 1-12) ================================ Port Type Priority Cost FastForwarding ------------------------------------------------------- 100TX DISABLED 100TX DISABLED 100TX DISABLED 100TX DISABLED 100TX DISABLED 100TX DISABLED 100TX DISABLED 100TX...
Page 56
ONSOLE NTERFACE Parameter Default Description (Path) Cost 100/19/4 This parameter is used by the STA algorithm to determine the best path between devices. Therefore, lower values should be assigned to ports attached to faster media, and higher values assigned to ports with slower media. (Path cost takes precedence over port priority.) The default and recommended range is: Ethernet:...
EVICE ONTROL Configuring Virtual LANs You can use the VLAN configuration menu to assign any port on the switch to any of up to 256 Virtual LAN groups. In conventional networks with routers, broadcast traffic is split up into separate domains.
Page 58
ONSOLE NTERFACE Parameter Default Description Group Address Registration Protocol is used by GARP GVRP and GMRP to register or deregister client attributes for client services within a bridged LAN. Join Time The interval (centiseconds) between transmitting requests/queries to participate in a group.
Page 59
EVICE ONTROL Parameter Default Description VLAN and Priority These fields set the default values for VLANs, port priority, GVRP and GMRP. Port VID The VLAN ID assigned to untagged frames received on this port. Port Default Set the default ingress priority to any value beneath the priority threshold (page 2-40) to Priority specify the low priority queue, or to any value...
Page 60
ONSOLE NTERFACE Parameter Default Description GVRP Enabled Enables or disables GVRP for this port. When disabled, any GVRP packets received on this port will be discarded and no GVRP registrations will be propagated from other ports. Note that GVRP must be enabled globally for the switch before this setting can take effect.
EVICE ONTROL VLAN Table Configuration Use this screen to create a new VLAN or modify the settings for an existing VLAN. VLAN Menu: VLAN Table Configuration ========= Port VLAN 12345678901234567890123456 SSSSSSSSSSSSSSSSSSSSSSSSSS -: Normal S: Static R: Reg. Fixed X: Forbidden Page : <Apply>...
ONSOLE NTERFACE Configuring IGMP Snooping Multicasting is used to support real-time applications such as video conferencing or streaming audio. A multicast server does not have to establish a separate connection with each client. It merely broadcasts its service to the network, and any hosts which want to receive the multicast register with their local multicast switch/ router.
Page 63
EVICE ONTROL You can use the IGMP Snooping Configuration screen to configure multicast filtering as shown below. IGMP Snooping Configuration =========================== IGMP Snooping Status : DISABLED IGMP Router Timeout (Minutes) : 5 IGMP Group Timeout (Minutes) Act as IGMP Querier : DISABLED <Apply>...
ONSOLE NTERFACE Configuring Security Filters You can use the Security menu to filter MAC addresses or to enable/disable address learning. Security Menu ============= MAC Filtering Configuration ... Security Mode ... <OK> Use <TAB> or arrow keys to move. <Enter> to select. Parameter Description MAC Filtering...
EVICE ONTROL Configuring MAC Address Filters Any node that presents a security risk or is functioning improperly can be filtered from this switch. You can drop all the traffic from a host device based on a specified MAC address. Traffic with either a source or destination address listed in the Security Filtering Configuration table will be filtered.
ONSOLE NTERFACE Security Mode The learning function enables ports to learn the <source MAC address, VLAN> pair of received frames. This information is then used to make later decisions for frame forwarding. The learning function should be initially enabled for a long enough period to ensure that all valid VLAN members have been registered on the switch.
ONITORING THE WITCH Monitoring the Switch The Network Monitor Menu provides access to port statistics, address tables, STA information, VLAN registration and forwarding information and multicast groups. Each of the screens provided by these menus is described in the following sections. Network Monitor Menu ==================== Port Statistics ...
ONSOLE NTERFACE Displaying Port Statistics Port Statistics displays standard statistics on network traffic from the Interfaces Group and Ethernet-like MIBs, as well as a detailed breakdown of traffic based on the RMOM MIB. Statistics Menu =============== Port Statistics ... RMON Statistics ... <OK>...
ONITORING THE WITCH Displaying Ethernet Port Statistics Port Statistics displays key statistics from the Interfaces Group and Ethernet-like MIBs for each port. Error statistics on the traffic passing through each port are displayed. This information can be used to identify potential problems with the switch (such as a faulty port or unusually heavy loading).
Page 70
ONSOLE NTERFACE Parameter Description In Discards The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
Page 71
ONITORING THE WITCH Parameter Description Ethernet-Like Single Collisions The number of successfully transmitted frames for which transmission is inhibited by exactly one collision. Deferred A count of frames for which the first transmission Transmissions attempt on a particular interface is delayed because the medium was busy.
ONSOLE NTERFACE Displaying RMON Statistics Use the RMON Statistics screen to display key statistics for each port from RMON group 1. (RMON groups 2, 3 and 9 can only be accessed using SNMP management software such as EliteView.) The following screen displays the overall statistics on traffic passing through each port.
Page 73
ONITORING THE WITCH Parameter Description Multicast Frames The total number of good frames received that were directed to this multicast address. CRC/Alignment Errors The number of CRC/alignment errors (FCS or alignment errors). Undersize Frames The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
ONSOLE NTERFACE Layer 2 Address Table This menu includes the unicast address table. Layer 2 Address Table ===================== Unicast Address Table ... <OK> Use <TAB> or arrow keys to move. <Enter> to select. Menu Description Unicast Provides a full listing for unicast addresses. Address Table 2-60...
ONITORING THE WITCH Displaying the Unicast Address Table The Unicast Address Table contains the MAC addresses associated with each port (that is, the source port associated with the address). The information displayed in the Address Table is indicated in the following figure and table.
ONSOLE NTERFACE Displaying Bridge Information The Bridge menu is used to display settings for the Spanning Tree Algorithm. For a more detailed description of how to use this algorithm, refer to “Spanning Tree Algorithm” on page 4-4. Bridge Menu ============ Spanning Tree Bridge Information ...
ONITORING THE WITCH Viewing the Current Spanning Tree Information The STA Bridge Information screen displays a summary of STA information for the overall bridge. To make any changes to these parameters, use the Bridge STA Configuration menu as described on page 2-38. The parameters shown in the following figure and table describe the current Bridge STA settings.
ONSOLE NTERFACE Parameter Description Hold Time The minimum interval between the transmission of consecutive Configuration BPDUs. Designated Root The priority and MAC address of the device in the Spanning Tree that this switch has accepted as the root device. Root Cost The path cost from the root port on this switch to the root device.
Page 79
ONITORING THE WITCH Parameter Description Type Shows port type as: 100TX : 10BASE-T / 100BASE-TX 100FX_MM : 100BASE-FX (multimode) 100FX_SM : 100BASE-FX (singlemode) 1000LX : 1000BASE-LX (singlemode) 1000SX : 1000BASE-SX (multimode) 1000T : 1000BASE-T Status Displays current state of this port within the Spanning Tree: Disabled No link has been established on this port.
ONSOLE NTERFACE Parameter Description Designated The priority and MAC address of the device through Bridge (ID) which this port must communicate to reach the root of the Spanning Tree. Designated The priority and number of the port on the designated Port (ID) bridging device through which this switch must communicate with the root of the Spanning Tree.
ONITORING THE WITCH VLAN Dynamic Registration Information This table shows the ports that have been automatically learned via GVRP. VLAN Dynamic Registration Information ===================================== Port VLAN 12345678901234567890123456 D: Dynamic Page : <Apply> Total: 1 Pages <OK> <Prev Page> <Next Page> Use <TAB>...
ONSOLE NTERFACE VLAN Forwarding Information Shows all the ports that have been configured by either dynamic or static means to forward VLAN traffic. VLAN Forwarding Information =========================== Port VLAN 12345678901234567890123456 SSSSSSSSSSS SSSSSSSSSSSSSS S: Static D: Dynamic Page : <Apply> Total: 1 Pages <OK>...
ONITORING THE WITCH IP Multicast Registration Table This table displays all the multicast groups active on the switch, including the multicast IP address and the corresponding VLANs. IP Multicast Registration Table =============================== VLAN Multicast IP 12345678901234567890123456 Learned by 234.7.6.99 IGMP Page <Apply>...
ONSOLE NTERFACE Resetting the System Use the Restart command under the Main Menu to reset the management agent. The reset screen is shown below. System Restart Menu =================== Restart Option : Reload Factory Defaults : NO <Restart> <Cancel> Use <TAB> or arrow keys to move, <Space> to scroll options. Parameter Description Reload Factory Defaults...
HAPTER NTERFACE Web-Based Configuration and Monitoring In addition to the menu-driven system configuration program, this switch also provides an embedded HTTP Web agent. Using a Web browser you can configure the switch and view statistics to monitor network activity. The Web agent can be accessed by any computer on the network using a standard Web browser (Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above).
Page 86
NTERFACE After you enter the user name and password, you will have access to the system configuration program illustrated by the following menu hierarchy: System System Information Switch Information Information Menu IP Configuration Management Network Configuration Setup Menu Serial Port Configuration SNMP Configuration SNMP Communities User Configuration...
AVIGATING THE ROWSER NTERFACE Navigating the Web Browser Interface To access the Web-browser interface you must first enter a user name and password. The administrator has Read/Write access to all configuration parameters and statistics. The default user name for the administrator is “admin,” with no password. Home Page When your Web browser connects with the switch’s Web agent, the home page is displayed as shown below.
NTERFACE Configuration Options Configurable parameters have a dialog box or a drop-down list. Once a configuration change has been made on a page, be sure to click on the “Apply” button at the bottom of the page to confirm the new setting. The following table summarizes the Web page configuration buttons.
ANEL ISPLAY Panel Display The Web agent displays an image of the switch’s ports, showing port links and activity. Clicking on the image of a port displays statistics and configuration information for the port. Clicking on the image of the serial port (labeled “Mgmt”) displays the Console Configuration screen.
NTERFACE Parameter Description Link Status Indicates if the port has a valid connection to an external device. Speed Status Indicates the current port speed. Duplex Status Indicates the port’s current duplex mode. Flow Control Status Shows the flow control type in use. Flow control can eliminate frame loss by “blocking”...
Page 91
ANEL ISPLAY Parameter Default Description Management Console Indicates that the port settings are for direct Mode Mode console connection. Baud Rate 19200 The rate at which data is sent between devices. Options : 9600, 19200 and 38400 baud. Data Bits 8 bits Sets the data bits of the RS-232 port.
NTERFACE Main Menu Using the onboard Web agent, you can define system parameters, manage and control the switch, and all its ports, or monitor network conditions. The interface screen includes the main menu on the left side, the menu bar beneath the image of the switch, and a list of commands beneath the menu bar.
YSTEM NFORMATION Menu Description VLAN Menu Configures VLAN settings for specific ports, and defines the port membership for VLAN groups. IGMP Snooping Configures IGMP multicast filtering. Configuration Security Menu Configures MAC address filtering, and enables or disables address learning. Network Monitor Menu Port Statistics Displays statistics on port traffic, including information from the Interfaces Group,...
NTERFACE Displaying System Information Use the System Information screen to display descriptive information about the switch, or for quick system identification as shown in the following figure and table. Parameter Description System Name* Name assigned to the switch system. Object ID MIB II object identifier for switch’s network management subsystem.
YSTEM NFORMATION Displaying Switch Version Information Use the Switch Information screen to display hardware/firmware version numbers for the main board, as well as the power status and modules plugged into the system. Main Board Parameter Description Hardware Version Hardware version of the main board. Firmware Version System firmware version in ROM.
NTERFACE Management Setup Menu After initially logging onto the system, you can use this menu to configure access rights. You should set user names and passwords (User Configuration). Remember to record them in a safe place. You should also set the community string which controls access to the onboard SNMP agent via in-band management software (SNMP Configuration).
ANAGEMENT ETUP Changing the Network Configuration Use the Network Configuration menu to set the bootup option and configure the switch’s IP parameters. The screen shown below is described in the following table. Parameter Description IP Address IP address of the switch you are managing. The system supports SNMP over UDP/IP transport protocol.
Page 98
NTERFACE Parameter Description IP State Specifies whether IP functionality is enabled via manual configuration, or set by Boot Protocol (BOOTP). Options include: User Configuration- IP functionality is enabled based on the default or user specified IP Configuration. (This is the default setting.) BOOTP Get IP - IP is enabled but will not function until a BOOTP reply has been received.
ANAGEMENT ETUP Assigning SNMP Parameters Use the SNMP Configuration screen to display and modify parameters for the Simple Network Management Protocol (SNMP). The switch includes an onboard SNMP agent which monitors the status of its hardware as well as the traffic passing through its ports.
NTERFACE Configuring IP Trap Managers The following figure and table describe how to specify management stations that will receive authentication failure messages or other trap messages from the switch. Up to 5 trap managers may be entered. Parameter Description IP Address IP address of the trap manager.
ANAGEMENT ETUP User Login Configuration Use the User Configuration screen to restrict management access based on user names and passwords. The default administrator (admin) has write access for parameters governing the onboard agent. You should therefore assign a password to the administrator as soon as possible, and store it in a safe place.
Use the TFTP Download menu to load software updates to permanent flash ROM in the switch. The download file should be an SMC6724L2 binary file from SMC; otherwise the agent will not accept it. The success of the download operation depends on the accessibility of the TFTP server and the quality of the network connection.
Page 103
ANAGEMENT ETUP Saving or Restoring the System Configuration Use the Configuration File menu to save the switch configuration settings to a file on a TFTP client. The file can be later downloaded to the switch to restore the switch’s settings. The success of the operation depends on the accessibility of the TFTP client and the quality of the network connection.
NTERFACE Device Control Menu The Device Control menu is used to control a broad range of functions, including port mode, port mirroring, port trunking, Spanning Tree, Virtual LANs, and multicast filtering. Each of the setup screens provided by these configuration menus is described in the following sections.
EVICE ONTROL Layer 2 Menu The Layer 2 menu contains options for port configuration, port mirroring, and port trunking. These menu options are described in the following sections. Menu Description Port Enables any port, enables/disables flow control, and Configuration sets communication mode to auto-negotiation, full duplex or half duplex.
Page 106
NTERFACE Parameter Default Description Link Status Indicates if the port has a valid connection to an external device. Admin Enabled Allows you to disable a port due to abnormal Status behavior (e.g., excessive collisions), and then reenable it after the problem has been resolved. You may also disable a port for security reasons.
Page 107
EVICE ONTROL Parameter Default Description For the Gigabit modules the options for flow control are set out below: Switch Link Partner* Flow Control SendOnly Rcv/BothWay Switch can only send pause frames, link partner can only receive pause frames. BothWay Rcv/BothWay Both switch and link partner can send and receive pause frames.
NTERFACE Using a Port Mirror for Analysis You can mirror traffic from any source port to a target port for real-time analysis. You can then attach a logic analyzer or RMON probe to the target port and study the traffic crossing the source port in a completely unobtrusive manner.
EVICE ONTROL Configuring Port Trunks Ports can be combined into an aggregate link to increase the bandwidth of a network connection or ensure fault recovery. You can configure trunks between any two SMC6724L2 or SMC6724L3 switches. The Ports 1-24 on this switch can be grouped into a trunk consisting of two, four or eight ports, creating an aggregate bandwidth up to 400, 800 or 1600 Mbps when operating at full duplex.
Page 110
NTERFACE Use the Trunk Configuration screen to set up port trunks as shown below: Parameter Description Trunk List The port groups currently configured as trunks. New Setting The port groups that can still be configured as trunks. The port groups permitted include: <<13, 1>>...
Page 111
EVICE ONTROL To add a trunk, highlight a port group in the New Setting list and press Add. To delete a trunk, highlight a port group in the Trunk List and press Delete. Before disconnecting a port trunk, take the following steps: •...
NTERFACE Static Unicast Address Table The Static Unicast Address Table can be used to assign the MAC address for a host device to a specific port on this switch. Static unicast addresses are never aged out, and cannot be learned by another port.
EVICE ONTROL Configuring the Static Multicast Address Table The Static Multicast Address Table can be used to assign a destination MAC address (and the corresponding ports) to the VLAN group used for a specific multicast service. Static multicast addresses are never aged out, and traffic with these addresses can be forwarded only to ports specified in this table.
NTERFACE Using the Bridge Menu The Bridge menu is used to configure settings for the Spanning Tree Algorithm, as well as the global bridge settings for GMRP (GARP Multicast Registration Protocol) and GVRP (GARP VLAN Registration Protocol), traffic classes priority threshold, and address aging time.
EVICE ONTROL Configuring Global Bridge Settings The following figure and table describe bridge configuration for STA, GMRP, GVRP, priority threshold, and address aging time. Parameter Default Description Spanning Tree Enabled Enable this parameter to participate in a STA compliant network. Bridge Priority 32,768 Bridge priority is used in selecting the root device, root port, and designated port.
Page 116
NTERFACE Parameter Default Description Forward Delay 15 The maximum time (in seconds) the root device will wait before changing states (that is, listening to learning to forwarding). This delay is required because every device must receive information about topology changes before it starts to forward frames.
Page 117
EVICE ONTROL Parameter Default Description GVRP Disabled GARP VLAN Registration Protocol (GVRP) defines a way for switches to exchange VLAN information in order to register VLAN members on ports across the network. This function should be enabled to permit automatic VLAN registration and to support VLANs which extend beyond the local switch.
NTERFACE Configuring STA for Ports The following figure and table describe port STA configuration. Parameter Default Description Type Shows port type as: 100BASE-TX: 10BASE-T / 100BASE-TX 100BASE-FX-MM: 100BASE-FX (multimode) 100BASE-FX-SM: 100BASE-FX (singlemode) 1GBase-SX: 1000BASE-SX (multimode) 1GBase-LX: 1000BASE-LX (singlemode) 1GBase-T: 1000BASE-T Priority Defines the priority for the use of a port in the STA algorithm.
EVICE ONTROL Parameter Default Description The default and recommended range is: Ethernet: 100 (50~600) Fast Ethernet: 19 (10~60) Gigabit Ethernet: 4 (3~10) The full range is 0 - 65535. Fast Enabled This parameter is used to enable/disabled the Forwarding* Fast Spanning Tree mode for the selected port. In this mode, ports skip the Blocked, Listening and Learning states and proceed straight to Forwarding.
NTERFACE VLAN Port Configuration You can use the VLAN Port Configuration screen to configure GARP, the default VLAN identifier, default port priority, VLAN tagging on outgoing frames, GVRP and GMRP status, and filtering incoming frames for VLAN groups to which this port does not belong. 3-36...
Page 121
EVICE ONTROL Parameter Default Description Group Address Registration Protocol is used GARP Configuration by GVRP and GMRP to register or deregister client attributes for client services within a bridged LAN. Join Time The interval (in centiseconds) between transmitting requests/queries to participate in a group.
Page 122
NTERFACE Parameter Default Description VLAN and Priority These fields set the default values for VLANs, port priority, GVRP and GMRP. Port VID The VLAN ID assigned to untagged frames received on this port. Port Default Set the default ingress priority to any value Priority beneath the priority threshold (page 3-33) to specify the low priority queue, or to any value...
Page 123
EVICE ONTROL Parameter Default Description Port GVRP Enabled Enables or disables GVRP for this port. When disabled, any GVRP packets received on this port will be discarded and no GVRP registrations will be propagated from other ports. Note that GVRP must be enabled globally for the switch before this setting can take effect.
NTERFACE VLAN Table Configuration Use this screen to create a new VLAN or modify the settings for an existing VLAN. Parameter Description VLAN The ID for the VLAN currently displayed. Range: 1-4094 (Port) Port entries may be marked as: N : (Normal) Uses GVRP to determine port membership. X : (Forbidden) Disables GVRP for this VLAN on the specified port.
EVICE ONTROL Configuring IGMP Snooping Multicasting is used to support real-time applications such as video conferencing or streaming audio. A multicast server does not have to establish a separate connection with each client. It merely broadcasts its service to the network, and any hosts which want to receive the multicast register with their local multicast switch/ router.
Page 126
NTERFACE Parameter Default Description IGMP Disabled If enabled, the switch will monitor network Snooping traffic to determine which hosts want to receive multicast traffic. This is also referred to Status as IGMP Snooping. IGMP Router A switch port that stops receiving multicast Timeout protocol packets for this interval will be removed from the IGMP forwarding list.
EVICE ONTROL Configuring Security Filters You can use the Security menu to filter MAC addresses or to enable the security mode. Parameter Description MAC Filtering Specifies the source or destination MAC address Configuration for any traffic to be filtered from the switch. Security Mode Disables learning of MAC addresses and specifies an uplink port.
NTERFACE Security Mode This menu can be used to disable the switch’s MAC address learning function. If the learning function is disabled, an uplink port must be specified to which the switch will forward all unknown packets. Parameter Description Learning Function Enables and disables the switch’s function of learning the source MAC address of incoming packets.
ONITORING THE WITCH Monitoring the Switch The Network Monitor Menu provides access to port statistics, address tables, STA information, VLANs registration and forwarding information, multicast groups, and subnet addresses. Each of the screens provided by these menus is described in the following sections.
NTERFACE Displaying Ethernet Port Statistics Port Statistics display key statistics from the Interfaces Group and Ethernet-like MIBs for each port. Error statistics on the traffic passing through each port are displayed. This information can be used to identify potential problems with the switch, such as a faulty port or unusually heavy loading.
Page 131
ONITORING THE WITCH Parameter Description In Discards The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
Page 132
NTERFACE Parameter Description Ethernet-Like Single Collisions The number of successfully transmitted frames for which transmission is inhibited by exactly one collision. Deferred A count of frames for which the first transmission Transmissions attempt on a particular interface is delayed because the medium was busy. Excessive Collisions The number of frames for which transmission failed due to excessive collisions.
ONITORING THE WITCH Displaying RMON Statistics Use the RMON Statistics screen to display key statistics for each port from RMON group 1. (RMON groups 2, 3 and 9 can only be accessed using SNMP management software such as EliteView.) The following screen displays the overall statistics on traffic passing through each port.
Page 134
NTERFACE Parameter Description Undersize Frames The total number of frames received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. Oversize Frames The total number of frames received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.
ONITORING THE WITCH Layer 2 Address Table This menu includes the unicast address table. Menu Description Unicast Address Table Provides a full listing for unicast addresses. Displaying the Unicast Address Table The Unicast Address Table contains the MAC addresses associated with each port (that is, the source port associated with the address).
NTERFACE Viewing the Current Spanning Tree Information The STA Bridge Information screen displays a summary of STA information for the overall bridge. To make any changes to these parameters, use the Bridge STA Configuration menu as described on page 3-31. The parameters shown in the following figure and table describe the current Bridge STA settings.
ONITORING THE WITCH Parameter Description Root Cost The path cost from the root port on this switch to the root device. Root Port The number of the port on this switch that is closest to the root. This switch communicates with the root device through this port.
Page 138
NTERFACE Parameter Description Status Displays current state of this port within the Spanning Tree: Disabled No link has been established on this port. Otherwise, the port has been disabled by the user or has failed diagnostics. Blocking Port receives STA configuration messages, but does not forward packets.
ONITORING THE WITCH Displaying VLAN Information These menus display information on the ports that have been automatically learned via GVRP and all those ports that have been configured by dynamic or static means to forward VLAN traffic. Menu Description VLAN Dynamic Shows the ports that have been automatically learned via Registration GVRP.
NTERFACE IP Multicast Registration Table This table displays all the multicast groups active on the switch, including the multicast IP address and the corresponding VLANs. Parameter Description VLAN A VLAN with host members that have asked to receive the indicated multicast service. Multicast IP A source IP address that represents a specific multicast service.
ESETTING THE YSTEM Resetting the System Use the Restart command under the Main Menu to reset the management agent. The reset screen is shown below. Parameter Description Reload Factory Defaults Reloads the factory defaults [Apply] Restarts the switch. Note: When restarting the system, it will always run the Power-On Self-Test.
HAPTER DVANCED OPICS The SMC6724L2 supports Layer 2 switching and other advanced features which are described in this chapter. Layer 2 Switching When a frame enters a port, its destination MAC address is checked in the address database to see which port leads to this destination.
DVANCED OPICS The following sections provide additional information about the tasks the switch performs during unicast and multicast switching. Unicast Switching This section describes VLAN classification, learning, filtering, and forwarding for unicast switching. • VLAN Classification—When the switch receives a frame, it classifies the frame in one of two ways: - If the frame is untagged, the switch classifies the frame into the default VLAN for the incoming port.
AYER WITCHING - If unknown, the switch floods the received frame to all ports in the VLAN, excluding the source port. - If known, the switch forwards the received frame to the port associated with the pair. At the same time, the switch decides whether a VLAN tag needs to be added to or stripped from the frame, depending on the VLAN tagged/untagged configuration and VLAN ID for the output port.
DVANCED OPICS Spanning Tree Algorithm The Spanning Tree Algorithm (that is, the STA-configuration algorithm as outlined in IEEE 802.1D) can be used to detect and disable network loops, and to provide link backup. This allows the switch to interact with other bridging devices (including STA- compliant switches, bridges or routers) in your network to ensure that only one route exists between any two stations on the network.
IRTUAL The following figure gives an illustration of how the Spanning Tree Algorithm assigns bridging device ports. Root Bridging Device Designated Port Designated Port Root Port Root Port Blocking Designated Port Designated Port Designated Port Root Port Root Port Root Port Virtual LANs Switches do not inherently support broadcast domains, which can lead to broadcast storms in large networks that handle a lot of...
DVANCED OPICS VLANs provide greater network efficiency by reducing broadcast traffic, and allow you to make network changes without having to update IP addresses or IP subnets. VLANs inherently provide a high level of network security since traffic must pass through a configured Layer 3 link to reach a different VLAN.
IRTUAL VLAN Classification When the switch receives a frame, it classifies the frame in one of two ways. If the frame is untagged, the switch assigns the frame to an associated VLAN (based on the PVID of the receiving port (page 2-43 and 3-36).
DVANCED OPICS the specified VLANs, and pass the message on to all other ports. VLAN requirements are propagated in this way throughout the network. This allows GVRP-compliant devices to be automatically configured for VLAN groups based solely on endstation requests. Forwarding Tagged/Untagged Frames Ports can be assigned to multiple tagged or untagged VLANs.
ULTICAST ILTERING Multicast Filtering Multicasting sends data to a group of nodes instead of a single destination. The simplest way to implement multicasting is to broadcast data to all nodes on the network. However, such an approach wastes a great deal of bandwidth if the target group is small compared to the overall broadcast domain.
DVANCED OPICS traffic, and allows you to significantly reduce the multicast traffic passing through your switch. IGMP Protocol The Internet Group Management Protocol (IGMP) runs between hosts and their immediately adjacent multicast router/switch. IGMP is a multicast host registration protocol that allows any host to inform its local router that it wants to receive transmissions addressed to a specific multicast group.
S) S LASS ERVICE UPPORT similar join packet to all other ports on the switch, informing them that incoming multicast traffic for the stated group is to be forwarded to the requesting port. Class-of-Service (CoS) Support The SMC6724L2 provides two transmit queues on each port, with a weighted fair queuing scheme.
DVANCED OPICS Security Features The SMC6724L2 provides security features which allow you to control management access and network access as described in the following sections. SNMP Community Strings Access to the switch using network management tools is controlled by SNMP community strings. This switch supports up to five community strings.
SNMP M ANAGEMENT OFTWARE MAC Address Filters If you discover that some nodes are sending abnormal or destructive data that could adversely affect the network or cause security problems, you can set their MAC addresses to be filtered by the switch. Any packets with a source or destination address listed in the MAC address filter will then be dropped by the switch upon entry.
DVANCED OPICS Remote Monitoring (RMON) Remote Monitoring provides a cost-effective way to monitor large networks by placing embedded or external probes on distributed network equipment (hubs, switches or routers). RMON has already become a valuable tool for network managers faced with a quickly changing network landscape that contains dozens to hundreds of separate segments.
Page 157
(RMON) EMOTE ONITORING certain amount over the set interval). Alarms can be set to respond to either rising or falling thresholds. Events: Defines the action to take when an alarm is triggered. The response to an alarm can include recording the alarm in the Log Table or sending a message to a trap manager.
PPENDIX ROUBLESHOOTING Troubleshooting Chart Troubleshooting Chart Symptom Action Cannot connect • Be sure to have configured the agent with a valid IP using Telnet, Web address, subnet mask and default gateway. browser, or SNMP software • If you are trying to connect to the agent via a specified tagged VLAN group, your management station must include the appropriate tag in its transmitted frames.
ROUBLESHOOTING Upgrading Firmware via the Serial Port You can upgrade system firmware by connecting your computer to the serial port on the switch and using a console interface package that supports the XModem protocol. (See “Required Connections” on page 1-2.) 1.
2. The download file should be an SMC6724L2 binary file from SMC; otherwise the agent will not accept it. 4. After the file has been downloaded, the console screen will display information similar to that shown below. Press Enter to...
PPENDIX SSIGNMENTS Console Port Pin Assignments The DB-9 serial port on the switch’s rear panel is used to connect to the switch for out-of-band console configuration. The onboard menu-driven configuration program can be accessed from a terminal, or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following tables.
SSIGNMENTS DB-9 Port Pin Assignments CCITT Description Switch’s PC DB9 Circuit Signal DB9 DTE Pin # Pin # RxD (Received Data) TxD (Transmitted Data) SGND (Signal Ground) No other pins are used. Console Port to 9-Pin DTE Port on PC Switch’s 9-Pin PC’s 9-Pin Null Modem...
LOSSARY Bandwidth Utilization The historical percentage of packets received as compared to total bandwidth. BOOTP Boot protocol used to load the operating system for devices connected to the network. GARP VLAN Registration Protocol (GVRP) Defines a way for switches to exchange VLAN information in order to register necessary VLAN members on ports along the Spanning Tree so that VLANs defined in each switch can work automatically over a Spanning Tree network.
Page 166
LOSSARY IEEE 802.1D Specifies a general method for the operation of MAC bridges, including the Spanning Tree Protocol. IEEE 802.1Q VLAN Tagging—Defines Ethernet frame tags which carry VLAN information. It allows switches to assign endstations to different virtual LANs, and defines a standard way for VLANs to communicate across switched networks.
Page 167
LOSSARY IP Multicast Filtering A process whereby this switch can pass multicast traffic along to participating hosts. Layer 2 Data Link layer in the ISO 7-Layer Data Communications Protocol. This is related directly to the hardware interface for network devices and passes on traffic based on MAC addresses. Layer 3 Network layer in the ISO 7-Layer Data Communications Protocol.
Page 168
LOSSARY Port Mirroring A method whereby data on a target port is mirrored to a monitor port for troubleshooting with a logic analyzer or RMON probe. This allows data on the target port to be studied unobstructively. Port Trunk Defines a network link aggregation and trunking method which specifies how to create a single high-speed logical link that combines several lower-speed physical links.
Page 169
LOSSARY Virtual LAN (VLAN) A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network. A VLAN serves as a logical workgroup with no physical barriers, and allows users to share information and resources as though located on the same LAN.
Page 176
FOR TECHNICAL SUPPORT, CALL: From U.S.A. and Canada (24 hours a day, 7 days a week) (800) SMC-4-YOU; (949) 707-2400; (949) 707-2460 (Fax) From Europe (8:00 AM - 5:30 PM UK Greenwich Mean Time) 44 (0) 1188 748740; 44 (0) 1189 748741 (Fax)
Need help?
Do you have a question about the 6724L2 - annexe 1 and is the answer not in the manual?
Questions and answers