Chapter
3
Emulation Submenus
XS Media 'D' Act
(From page 183.) This option defines in which media mode PPI2 will operate
on receipt of a 'D' (strip mode) for the issue mode parameter in the XS
command. Any of the supported media modes can be selected. When you
select "Ignore," PPI2 will use the issue mode as configured through "Media
Handling" under the "MEDIA CONTROL" menu.
The factory default is Tear-Off.
ZPL Compatible
(From page 181.) This menu allows you to select the compatibility to ZPL-I or
ZPL-II.
ZPL-I = Zebra Programming Language I.
ZPL-II = Zebra Programming Language II.
The factory default is ZPL-II.