Table 17. LCD Message Troubleshooting Table
Can User
Displayed Message
Correct?
SHUT DRVR CIR*
No
SHUTL INV CMD*
No
SHUTL INV PARM*
No
SHUTTLE JAM
Yes
SHUTTLE TYPE
No
NOT SUPPORTED*
SOFTWARE
No
ERROR*
STACK
No
OVERFLOW*
Explanation
The shuttle driver
Contact your authorized
circuit on the PSA3
service representative.
controller board is
drawing too much
current.
Fatal firmware
Contact your authorized
error on controller
service representative.
board.
Fatal firmware
Contact your authorized
error on controller
service representative.
board.
No shuttle
Check for obstruction to
movement or
shuttle, a twisted ribbon,
shuttle moving at
or forms thickness lever
wrong speed.
closed too tightly. If fault
source is not apparent,
contact your authorized
service representative.
The shuttle type
Contact your authorized
was not properly
service representative.
detected at
powerup.
Application
Contact your authorized
software tried to
service representative.
perform illegal
printer function, or
damaged logic
circuits found on
controller board.
Fatal firmware
Contact your authorized
error on controller
service representative.
board.
Fault Messages
Solution
1
1
1
1
1
1
319