Console Port Login Configuration with Authentication Mode Being Scheme
Configure to authenticate users logging in through the Console port in the
■
scheme mode.
The baud rate of the Console port is 19,200 bps.
■
The screen can contain up to 30 lines.
■
The history command buffer can store up to 20 commands.
■
The timeout time of the AUX user interface is 6 minutes.
■
Network diagram
Figure 7 Network diagram for AUX user interface configuration (with the authentication
mode being scheme)
RS-232
Configuration cable
PC
Configuration procedure
# Enter system view.
<SW7750> system-view
# Create a local user named guest and enter local user view.
[SW7750] local-user guest
# Set the authentication password to 1234567890 (in plain text).
[SW7750-luser-guest] password simple 1234567890
# Set the service type of the local user to Terminal, with the available command
level being 2.
[SW7750-luser-guest] service-type terminal level 2
[SW7750-luser-guest] quit
# Enter AUX user interface view.
[SW7750] user-interface aux 0
# Configure to authenticate users logging in through the Console port in the
scheme mode.
[SW7750-ui-aux0] authentication-mode scheme
# Set the baud rate of the Console port to 19,200 bps.
[SW7750-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[SW7750-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store
to 20.
Console port
Switch
49