Console Port Login Configuration with Authentication Mode Being Password
Table 16 Console port login configuration with the authentication mode being password
Operation
Enter AUX user interface
view
Configure to
authenticate users using
the local password
Set the local password
Configure
Set the
the
baud rate
Console
port
Set the
check
mode
Set the
flow
control
mode
Set the
stop bits
Set the
data bits
Configure the command
level available to users
logging into the user
interface
Make terminal services
available to the user
interface
Set the maximum
number of lines the
screen can contain
Set history command
buffer size
Command
user-interface aux 0
authentication-mode
password
set authentication
password { cipher |
simple } password
speed speed-value
parity { even | mark |
none | odd | space }
flow-control { hardware
| none | software }
stopbits { 1 | 1.5 | 2 }
databits { 7 | 8 }
user privilege level level
shell
screen-length
screen-length
history-command
max-size value
Description
-
Required
By default, users logging into a switch
through the Console port are not
authenticated; while those logging in
through Modems or Telnet are
authenticated.
Required
Optional
The default baud rate of an AUX port
(also the Console port) is 9,600 bps.
Optional
By default, the check mode of a
Console port is set to none, that is, no
check bit.
Optional
By default, a Console port does not
perform flow control.
Optional
The default stop bits of a Console port
is 1.
Optional
The default data bits of a Console port
is 8.
Optional
By default, commands of level 3 are
available to users logging into the
AUX user interface.
Optional
By default, terminal services are
available in all user interfaces.
Optional
By default, the screen can contain up
to 24 lines.
You can use the screen-length 0
command to disable the function to
display information in pages.
Optional
The default history command buffer
size is 10. That is, a history command
buffer can store up to 10 commands
by default.
43