BPDU Tunnel
Configuration
Example
[SW7750-mst-region] region-name example
[SW7750-mst-region] instance 1 vlan 10
[SW7750-mst-region] instance 3 vlan 30
[SW7750-mst-region] instance 4 vlan 40
[SW7750-mst-region] revision-level 0
# Activate the settings of the MST region.
[SW7750-mst-region] active region-configuration
Network requirements
Switch 7750s operate as the access devices of the operator's network, that is,
■
Switch C and Switch D in the network diagram.
S2000 series switches operate as the access devices of the user's network, that
■
is, Switch A and Switch B in the network diagram.
Switch C and Switch D connect to each other through the configured trunk
■
port of the switch, and are enabled with the BPDU Tunnel function. Thereby
transparent transmission is realized between the user's network and the
operator's network.
Network diagram
Figure 67 Network diagram for BPDU Tunnel configuration
Switch C
E 1/0/2
E 1/0/1
E 1/0/1
Switch A
Configuration procedure
1 Configure Switch A.
# Enable RSTP.
<SW7750> system-view
[SW7750] stp enable
# Add port Ethernet1/0/1 to VLAN 10.
[SW7750] vlan 10
[SW7750-Vlan10] port Ethernet 1/0/1
2 Configure Switch B.
# Enable RSTP.
BPDU Tunnel Configuration Example
Switch D
E 1/0/1
E 1/0/2
E 1/0/1
Switch B
277